UM, MC3 Safety Mat/Safety Mat Controller
1 / 19ページ

{{requestButtons}}

カタログの抜粋

UM, MC3 Safety Mat/Safety Mat Controller - 1

Safety Mat / Safety Mat Controller UM/MC3 Stay one step ahead in safety

カタログの1ページ目を開く
UM, MC3 Safety Mat/Safety Mat Controller - 2

S a fe t y M a t s a r e s a fe t y m e a s u r e s t h a t t a k e i n t o c o n s i d e r a t i o n u s a b i l i t y i n t h e wo r k p l a c e . OMRON Safety Mats continue on their unique path of evolution. On-site safety can be fur ther improved by placing Safety Mats precisely in areas where other sensors do not reach. The tion. Safety Mats elicit the full power of every location and are suitable for any application. Reduce labor associated with cumbersome layout, installation and maintenance The UM system takes the site into con m consideration n Connectors make wiring simple 1...

カタログの2ページ目を開く
UM, MC3 Safety Mat/Safety Mat Controller - 3

Safety Mat/Safety Mat Controller UM/MC3 New Safety Mat That Is Easy to Install and Maintain • Simple connection allows multiple mats to be joined together. • A wide variety of mat sizes are available. • Obtained EN1760-1 and EN ISO13849-1 (PLd/Safety Category 3) certification. • Complies with North American safety standards, including ANSI/RIA15.06-1999. Be sure to read the "Safety Precautions" on page 14. Model Number Structure Model Number Legend Safety Mat UM@@@-@-@ Base ––– – – 1 2 3 4 B 5 1. Color None : Black Y : Yellow 2. Unit of Length None : Inch M : Millimeter 3. Cable Length 5...

カタログの3ページ目を開く
UM, MC3 Safety Mat/Safety Mat Controller - 4

UM/MC3 Trims Appearance Name Model Remarks Ramp Trim with Yellow PVC Cover (1.22 m) UMRT4 Ramp Trim with Yellow PVC Cover (2.44 m) UMRT8 Installed on the perimeter of the Safety Mat. Each Trim is composed of two parts, an aluminum base and a PVC Cover. Possible to install cables inside. Joining Trim (1.22 m) UMJS4 Joining Trim (2.44 m) UMJS8 The Joining Trims join the Safety Mats when two or more Safety Mats are being combined. In addition to joining the Safety Mats, the Joining Trims preserve the Safety Mat's sensitivity at the joints. Aluminum Ramp Trim (2.44 m) UMAL Installed on the...

カタログの4ページ目を開く
UM, MC3 Safety Mat/Safety Mat Controller - 5

UM/MC3 Specifications Ratings Safety Mat Controller Power input Item Model MC3 Power voltage 24 VDC Operating voltage range -15% to +15% of rated supply voltage Power consumption * 3 W max. * Power consumption of loads is not included. Switch Item Model MC3 Rated load 6 A at 230 VAC/6 A at 24 VDC (resistive load) 5 A at 230 VAC (AC15)/2 A at 24 VDC (DC13) (inductive load) Maximum rated voltage 250 VAC/24 VDC Rated carry current 6A Maximum switching capacity 1,500 VA Characteristics Safety Mat Item Model UM Detection method Pressure sensing method Detection weight 30 kg min. Maximum...

カタログの5ページ目を開く
UM, MC3 Safety Mat/Safety Mat Controller - 6

UM/MC3 Installation Using Trim Pieces Example 2: Using three Safety Mats Ramp Trim with Yellow PVC Cover: UMRT4/UMRT8 Secures the edges of the Safety Mats to the floor. It is composed of two parts with an aluminum base and a PVC Cover. Joining Trim: UMJS4/UMJS8 The Joining Trims join the Safety Mats when two or more Safety Mats are being combined. In addition to joining the Safety Mats, the Joining Trims preserve the Safety Mat's sensitivity at the joints. Aluminum Ramp Trim: UMAL Secures the edges of the Safety Mat to the floor. The Aluminum Ramp Trim is hollow, so cable can be routed...

カタログの6ページ目を開く
UM, MC3 Safety Mat/Safety Mat Controller - 7

UM/MC3 Wiring of Safety Mat and Safety Mat Controller Example 1: Using a Single Safety Mat Safety Mat UM@ Example 2: Using Two Safety Mats Safety Mat UM@ Panel-mount Connector UMPMC Y Connector UM-Y-2-1 Panel-mount Connector UMPMC Safety Mat Controller MC3 Note: You can cut a Safety Mat's cable and wire it to the MC3 Safety Mat Controller without using UMPMC. Safety Mat Controller MC3 Safety Mat UM@ Example 3: Using Six Safety Mats Connecting directly to Safety Mat Controller Safety Mat UM@ Safety Mat UM@ Distribution Box (for six mats) UMDB-6 Connector with cable Socket on one cable end...

カタログの7ページ目を開く
UM, MC3 Safety Mat/Safety Mat Controller - 8

UM/MC3 Connections Internal Connection Y2 X1 Y1 Power supply X2 13 23 31 41 14 24 32 42 Control Circuit M11 M12 M21 M22 Wiring of Inputs and Outputs Signal name Terminal name Power supply input Description of operation Wiring Y1, Y2 Connect the power supply plus (24 VDC) to the Y1 Power supply input terminals for MC3 terminal. Connect the power source to the Y1 and Y2 terminals. Connect the power supply minus (GND) to the Y2 terminal. M11, M12, M21, M22 To turn ON safety outputs, all the connected safety mats must have no load. Otherwise, the safety outputs will NOT turn ON. M12 Safety Mat...

カタログの8ページ目を開く
UM, MC3 Safety Mat/Safety Mat Controller - 9

UM/MC3 Dimensions (Unit: mm) Safety Mat Controller MC3 Terminal/LED arrangements Y2 Y1 X1 X2 M11 M12 M21 M22 LED (red) Lights when the safety output from the MC3 Safety Mat Controller is OFF 110 LED (green) Lights when the safety output from the MC3 Safety Mat Controller is ON 15.3 55 84 Stop Run Mat Clear LED (green) Lights when the UM Safety Mat is not being activated (i.e., when intrusion is not being detected) 13 14 23 24 31 32 41 42 98 38 75 61.2 Two, R2.2 Trims Ramp Trim with Yellow PVC Cover UMRT@ Molded Outside Corner UMOC 58.4 30.6 28.6 72.4 91.4 94.6 58.4 Joining Trim UMJS@ 30.6...

カタログの9ページ目を開く
UM, MC3 Safety Mat/Safety Mat Controller - 10

UM/MC3 Accessories Distribution Box UMDB-6 Mounting hole dimensions 101.6 MAT3 MAT4 MAT2 MAT5 38.1 228.6 217.4 215.9 38.1 MAT1 MAT6 60.5 38.1 115.8 78.2 75.7 38.1 50.8 Y Connector UM-Y-2-1 Panel-mount Connector UMPMC Pin arrangement Internal wiring 1 (Brown) 49.9 4: Black 1: Brown 3: Red/black 2: Red/white Male 2 (White) 4 (Black) Female B 3 (Blue) M12×1 4 1 19.1 Female A 20 3 2 1 4 3: Blue 2: White 15.5 11.5 304.8 Extension Cable UMEC-03, UMEC-05 UMEC-10, UMEC-15 L* Pin arrangement * Cable length Female (socket) Model L (m) Model UMEC-03 3 UMEC-05 5 Male (plug) L (m) 10 UMEC-15 2 (White) 2...

カタログの10ページ目を開く
UM, MC3 Safety Mat/Safety Mat Controller - 11

UM/MC3 Application Examples PL/safety category Model Stop category Reset 0 Manual/Auto Safety Mat/Safety Mat Controller UM@+MC3 Safety Door Switch D4GS-N/D4NS/D4BS Safety Relay Unit G9SB PLe/3 equivalent (A Safety Relay Unit or Safety Controller other than the G9SB can be used.) Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. Application Overview • The power supply to the motor M is turned OFF when a person steps on the mat. • The power supply to the motor M is turned...

カタログの11ページ目を開く

OMRON/オムロンのすべてのカタログと技術パンフレット

  1. D4F

    8 ページ

  2. D4GS-N

    11 ページ

  3. E4E2

    5 ページ

  4. G9SE Series

    20 ページ

  5. NX-SL/SI/SO

    20 ページ

  6. G9SP

    28 ページ

  7. G9SX-SM

    24 ページ

  8. G9SX-SM/LM

    9 ページ

  9. G9SX/G9SX-GS

    49 ページ

  10. G9SX-LM

    28 ページ

  11. G9SB

    10 ページ

  12. G9SA

    16 ページ

  13. DST1 Series

    5 ページ

  14. WS02-CFSC1-E

    3 ページ

  15. G9SA-300-SC

    9 ページ

  16. K8AK-AS

    12 ページ

  17. K8AK-AW

    16 ページ

  18. K8AK-VS

    12 ページ

  19. K8AK-VW

    12 ページ

  20. K8AK-PH

    12 ページ

  21. K8DS-PH

    12 ページ

  22. K8AK-PM

    16 ページ

  23. K8DS-PM

    12 ページ

  24. K8AK-PA

    12 ページ

  25. K8DS-PA

    12 ページ

  26. K8AK-PW

    12 ページ

  27. K8DS-PU

    12 ページ

  28. K8DS-PZ

    12 ページ

  29. K8AK-TS/PT

    12 ページ

  30. K8AK-LS

    12 ページ

  31. K8AK-TH

    12 ページ

  32. K2CM

    16 ページ

  33. SE

    15 ページ

  34. SAO

    13 ページ

  35. APR-S

    6 ページ

  36. XS5

    25 ページ

  37. XS2

    29 ページ

  38. F92A

    4 ページ

  39. GLS

    3 ページ

  40. TL-L

    5 ページ

  41. V680 series

    68 ページ

  42. V680S Series

    68 ページ

  43. MY

    35 ページ

  44. E3NC-L/-S

    16 ページ

  45. 61F-GPN-BT / -BC

    5 ページ

  46. NE1A-SCPU Series

    8 ページ

  47. NE1A-SCPU0[]-EIP

    8 ページ

  48. NE0A-SCPU01

    6 ページ

  49. LY

    14 ページ

  50. G2R-[]-S

    11 ページ

  51. G7T

    7 ページ

  52. G2A

    9 ページ

  53. G2A-434

    7 ページ

  54. G2AK

    7 ページ

  55. MK-S

    9 ページ

  56. MK-S(X)

    12 ページ

  57. MM

    17 ページ

  58. MMK

    14 ページ

  59. G4Q

    6 ページ

  60. G7Z

    9 ページ

  61. G7J

    10 ページ

  62. E4B

    12 ページ

  63. E4A-3K

    9 ページ

  64. E4C-UDA

    5 ページ

  65. E6H-C

    5 ページ

  66. E6F-C

    5 ページ

  67. E6D-C

    5 ページ

  68. E6B2-C

    5 ページ

  69. E6A2-C

    5 ページ

  70. NL

    8 ページ

  71. VB

    5 ページ

  72. SC

    5 ページ

  73. D5F

    5 ページ

  74. D5A

    8 ページ

  75. E3S-GS3E4

    3 ページ

  76. E3S-R

    11 ページ

  77. E3S-A

    21 ページ

  78. E3S-CL

    9 ページ

  79. E3ZM-C

    14 ページ

  80. E3T Data Sheet

    26 ページ

  81. E3T Series

    6 ページ

  82. G5 Series

    59 ページ

  83. Sysmac Catalog

    410 ページ

  84. VT-X700

    6 ページ

  85. E5AC-T

    8 ページ

  86. CP1

    12 ページ

  87. CP1E

    12 ページ

  88. MS4800

    40 ページ

  89. VC-DL100

    6 ページ

  90. FZ4 Series

    42 ページ

  91. ZG2

    16 ページ

  92. ZS Series

    32 ページ

  93. ZW Series

    24 ページ

  94. E9NC-T

    2 ページ

  95. CompoNet

    28 ページ

  96. Code Reader/OCR

    24 ページ

  97. NT series

    18 ページ

  98. Photomicro Sensors

    7 ページ

  99. H8PS Cam Positioner

    32 ページ

  100. FQ Vision Sensor

    17 ページ

  101. E2EF

    8 ページ

  102. FQ2 Smart camera

    24 ページ

カタログアーカイブ

  1. SMART REMOTE I/O

    12 ページ

  2. Sensor Accessories

    38 ページ

  3. REGULATION SOLUTIONS

    24 ページ

  4. Vision Systems

    20 ページ