カタログの抜粋

omRonThree-phase Voltage and Phase-sequence Phase-loss RelayK8DS-PM Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. • Greater resistance to inverter noise. new • Monitor undervoltages, overvoltages, phase sequence, and phase loss in three-phase three-wire circuits with one unit. • One SpDt output relay, 5 A at 250 VAC (resistive load). •World-wide power specifications supported by one unit. (Set with a rotary switch.) •Relay status can be monitored using LED indicator. A Refer to Safety Precautions on page 9. Refer to page 7 for commonly asked questions. Ordering Information List of Models Note: The input range is set with a rotary switch. * The power supply voltage is the same as the rated input voltage.
カタログの1ページ目を開く
Specifications Input frequency •Relationship of Mounting Distance between K8DS-PM Relays and Ambient Temperature (Reference Values) The following diagram shows the relationship between the mounting distances and the ambient temperature. If the relay is used with an ambient temperature that exceeds these values, the temperature of the K8DS may rise and shorten the life of the internal components. DIN Track Distance between products: d
カタログの3ページ目を開く
Connections Terminal Diagram Control Output L1 Relay output 250 VAC, 5 A (resistive load) 30 VDC, 5 A (resistive load) Input Voltages Note: Use the recommended ferrules if you use twisted wires. Power supply AC/DC Timing Charts ●Overvoltage/Undervoltage and Phase Sequence/Phase Loss Operation Diagram Operation Table Overvoltage set value Hysteresis: Fixed at 5% L1 Input L2 L3 Undervoltage set value Indicators RY_LED Contact operation Incorrect phase t1: Power ON lock (1 s) t1 Phase Loss Operation Undervoltage Phase loss Alarm indicator Flashing Flashing Alarm indicator Relay 11-14 Note: 1....
カタログの4ページ目を開く
NomenclatureFront Terminal block (See notes 1 and 2.) Input voltage range rotary switch Overvoltage knob (OVER) Undervoltage knob (UNDER) Operating time knob (T) Terminal block (See notes 1 and 2.) Power indicator Relay status indicator Alarm indicator •Indicators Item * This indicator uses the input across L2 and L3 as the internal power supply. It will not light unless there is an input across L2 and L3. •Setting Knobs Item Note: 1. Use either a solid wire of 2.5 mm2 maximum or a ferrule with insulating sleeve for the terminal connection. The length of the exposed current-carrying part...
カタログの5ページ目を開く
K8DS-PM Setting Methods ●Overvoltage The overvoltage knob (OVER) is used to set the overvoltage threshold. The overvoltage can be set to between −30% and 25% of the rated input voltage. Turn the knob while there is an input to the input terminals until the alarm indicator flashes (when the set value and the input have reached the same level.) Use this as a guide to set the voltage. The rated input depends on the model and the rotary switch setting. Example: K8DS-PM1 with Rotary Switch Set to 200 V The rated input is 200 VAC and the setting range is 140 to 250 V. ●Undervoltage Undervoltage...
カタログの6ページ目を開く
Checking Operation How to Measure the Operating Time Overvoltage Change the input suddenly from 70% to 120% of the set value and measure the time until the Unit operates. Undervoltage Change the input suddenly from 120% to 70% of the set value and measure the time until the Unit operates. Operating Time Adjust the slide resistor so that the voltage applied to the K8DS terminals is 120% of the set value for overvoltage detection or 80% of the set value for undervoltage detection when the auxiliary relay in connection diagram 2 operates. Close the switch and use a cycle counter to measure the...
カタログの7ページ目を開く
Load-side Phase Loss In principle, phase loss cannot be detected on the load side because the K8DS-PM measures three-phase voltage to determine phase loss. Motor Load Phase Loss during Operation Motor load phase loss cannot be detected during operation. It can be used to detect phase loss at startup. Normally, three-phase motors will continue to rotate even if one phase is open. The three-phase voltage will be induced at the motor terminals. The diagram shows voltage induction at the motor terminals when phase R has been lost with a load applied to a three-phase motor. The horizontal axis...
カタログの8ページ目を開く
Safety Precautions Be sure to read the precautions for all models in the website at the following URL: http://www.ia.omron.com/. Warning Indications There is a risk of minor electrical shock, fire, or device failure. Do not allow any pieces of metal, conductors, or cutting chips that occur during the installation process to enter the product. Explosions may cause minor injuries. Do not use the product in locations with inflammable or explosive gases. There is a risk of minor electrical shock, fire, or device failure. Do not disassemble, modify, repair, or touch the inside of the product....
カタログの9ページ目を開く
Precautions for Safe Use 1. Do not use or store the product in the following locations. • Locations subject to water or oil • Outdoor locations or under direct sunlight • Locations subject to dust or corrosive gases (particularly sulfurizing gases, ammonia, etc.) • Locations subject to rapid temperature changes 5. To reduce the error in the setting knob, always turn the setting knob from the minimum setting toward the maximum setting. 6. Phase loss is detected only when the power supply to the motor is turned ON. Phase loss during motor operation is not detected. 7. Phase loss can be...
カタログの10ページ目を開く
Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS...
カタログの11ページ目を開くOMRON/オムロンのすべてのカタログと技術パンフレット
-
D4F
8 ページ
-
D4GS-N
11 ページ
-
E4E2
5 ページ
-
Fiber Unit E32-LT/LD
4 ページ
-
G9SE Series
20 ページ
-
NX-SL/SI/SO
20 ページ
-
G9SP
28 ページ
-
G9SX-SM
24 ページ
-
G9SX-SM/LM
9 ページ
-
G9SX/G9SX-GS
49 ページ
-
G9SX-LM
28 ページ
-
G9SB
10 ページ
-
G9SA
16 ページ
-
DST1 Series
5 ページ
-
WS02-CFSC1-E
3 ページ
-
G9SA-300-SC
9 ページ
-
K8AK-AS
12 ページ
-
K8AK-AW
16 ページ
-
K8AK-VS
12 ページ
-
K8AK-VW
12 ページ
-
K8AK-PH
12 ページ
-
K8DS-PH
12 ページ
-
K8AK-PM
16 ページ
-
K8AK-PA
12 ページ
-
K8DS-PA
12 ページ
-
K8AK-PW
12 ページ
-
K8DS-PU
12 ページ
-
K8DS-PZ
12 ページ
-
K8AK-TS/PT
12 ページ
-
K8AK-LS
12 ページ
-
K8AK-TH
12 ページ
-
K2CM
16 ページ
-
SE
15 ページ
-
SAO
13 ページ
-
APR-S
6 ページ
-
XS5
25 ページ
-
XS2
29 ページ
-
F92A
4 ページ
-
GLS
3 ページ
-
TL-L
5 ページ
-
V680 series
68 ページ
-
V680S Series
68 ページ
-
MY
35 ページ
-
E3NC-L/-S
16 ページ
-
61F-GPN-BT / -BC
5 ページ
-
NE1A-SCPU Series
8 ページ
-
NE1A-SCPU0[]-EIP
8 ページ
-
NE0A-SCPU01
6 ページ
-
LY
14 ページ
-
G2R-[]-S
11 ページ
-
G7T
7 ページ
-
G2A
9 ページ
-
G2A-434
7 ページ
-
G2AK
7 ページ
-
MK-S
9 ページ
-
MK-S(X)
12 ページ
-
MM
17 ページ
-
MMK
14 ページ
-
G4Q
6 ページ
-
G7Z
9 ページ
-
G7J
10 ページ
-
E4B
12 ページ
-
E4A-3K
9 ページ
-
E4C-UDA
5 ページ
-
E6H-C
5 ページ
-
E6F-C
5 ページ
-
E6D-C
5 ページ
-
E6B2-C
5 ページ
-
E6A2-C
5 ページ
-
NL
8 ページ
-
VB
5 ページ
-
SC
5 ページ
-
D5F
5 ページ
-
D5A
8 ページ
-
E3S-GS3E4
3 ページ
-
E3S-R
11 ページ
-
E3S-A
21 ページ
-
E3S-CL
9 ページ
-
E3ZM-C
14 ページ
-
E3T Data Sheet
26 ページ
-
E3T Series
6 ページ
-
G5 Series
59 ページ
-
Sysmac Catalog
410 ページ
-
VT-X700
6 ページ
-
E5AC-T
8 ページ
-
CP1
12 ページ
-
CP1E
12 ページ
-
MS4800
40 ページ
-
VC-DL100
6 ページ
-
FZ4 Series
42 ページ
-
ZG2
16 ページ
-
ZS Series
32 ページ
-
ZW Series
24 ページ
-
E9NC-T
2 ページ
-
Vision System FH series
54 ページ
-
CompoNet
28 ページ
-
Code Reader/OCR
24 ページ
-
NT series
18 ページ
-
Safety Controller G9SP
28 ページ
-
Data Logger ZR-RX Series
12 ページ
-
DeviceNet Safety System
30 ページ
-
Switching Power Supplies
16 ページ
-
Photomicro Sensors
7 ページ
-
Displacement Sensors
4 ページ
-
H8PS Cam Positioner
32 ページ
-
FQ Vision Sensor
17 ページ
-
E2EF
8 ページ
-
FQ2 Smart camera
24 ページ
カタログアーカイブ
-
SMART REMOTE I/O
12 ページ
-
Sensor Accessories
38 ページ
-
REGULATION SOLUTIONS
24 ページ
-
Vision Systems
20 ページ