For the most recent information on models that have been certified for safety standards, refer to your OMRON website. The G9SA Series Offers a Complete Line-up of Compact Units. • Four kinds of 45-mm wide Units are available: A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a Two-hand Controller. Also available are 17.5-mm wide Expansion Units with 3 poles and 3 OFF-delay poles. • Simple expansion connection. • OFF-delay models have 15-step OFF-delay settings. • Conforms to EN ISO13849-1 (PLe/Safety Category 4) *. • Both DIN track mounting and screw mounting are possible. * Except for some models. Refer to "Applicable Performance Level (PL)" on page 13, or "Reliability data for safety of control components_SISTEMA library" on OMRON's website. A Be sure to read the “Safety Precautions”on page 15 Model Number Structure Model Number Legend Note: 1. Please see “Ordering Information” on page 2 for the actual models that can be ordered. 2. Specify the power supply voltage when ordering. 1. Function None: Emergency stop EX: Expansion Unit 5. Input Configuration None: 1-channel or 2-channel input possible 6. OFF-delay Time (Max. setting time) None: No OFF-delay T075: 7.5 seconds T1 5: 15 seconds

カタログの1ページ目を開く
G9SA - 2

| Specify the power supply voltage when ordering. Emergency-stop Units Note: Set to maximum values in the factory.

カタログの2ページ目を開く
G9SA - 3

Power Input Item Model * When an Expansion Unit is connected, the power consumption is increased by 2 VA/2 W max. Inputs Item Model * When an Expansion Unit is connected, the input current is increased by 30 mA max. Contacts *1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method. *2. Not Including bounce time. *3. The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time. *4. The insulation resistance was measured with 500 VDC at the same places that the dielectric strength was checked. *5....

カタログの3ページ目を開く
G9SA - 4

Control circuit Control circuit Control circuit Control circuit Control circuit Control circuit Control circuit Control circuit Note: 1. With 100 to 240-VAC type, be sure to connect PE to a protective ground. With 24-VAC/VDC type, if the power supply is not connected to a protective ground, be sure to connect PE to a protective ground. 2. With 24-VAC/VDC type, the power supply terminals A1 and A2 have polarities. A2 is the negative pole. *1. Use terminals A and B to switch reset mode. A to B open: Manual reset A to B closed: Auto-reset *2. Terminal T23 is used for 2-channel input with a...

カタログの4ページ目を開く
G9SA - 5

*1. Terminal T23 Terminal T23 is used for 2-channel input with a positive common (when connecting a safety sensor with a PNP output). When T23 is being used, please open T21 and T22. For 1-channel input, short circuit T12-T23 before use. *2. Output Contacts G9SA-301: Safety Output Contacts 13-14, 23-24, 33-34. Auxiliary Contact 41-42. G9SA-501: Safety Output Contacts 13-14, 23-24, 33-34, 43-44, 53-54. Auxiliary Contact 61-62. G9SA-321-TQ Safety Output Contacts 13-14, 23-24, 33-34. Safety OFF-delay Output Contact 43-44, 53-54. Auxiliary Contact 61-62. *3. Terminals A and B A-B Opening:...

カタログの5ページ目を開く
G9SA - 6

Dimensions and Terminal Arrangement Twenty, M3 Twenty-four, M3 Twenty-four, M3 Twenty-one, M3 Connector cover * Note 1: The OFF-delay time setting switch is found on the G9SA-321-T@ only. 2: The K1 to K4 indicators light when the NO contacts of internal relays K1 to K4 close. * Do not remove unless an Expansion Unit is being used. PWR (green) K1 (green) K2 (green) OFF-delay time setting switch (See note 1) Note 1: The OFF-delay time setting switch is found on the G9SA-EX031-T@ only. 2: The K1 and K2 indicators light when the NO contacts of internal relays K1 and K2 close. OFF-delay time...

カタログの6ページ目を開く
G9SA - 7

Application ExamplesG9SA-301 (24 VAC/VDC) with 2-channel Limit Switch Input/Auto-reset Highest achievable PL/ safety category Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. •Application Overview • The power supply to the motor M is turned OFF when the S1 and S2 detect that the guard is opened. • The power supply to the motor M is kept OFF until the guard is closed. Timing Chart Limit switches S1 and S2 _ S1: Safety limit switch KM1 and KM2: Magnetic contactor...

カタログの7ページ目を開く
G9SA - 8

G9SA-301 (24 VAC/VDC) with 2-channel Limit Switch Input/Manual Reset Highest achievable PL/ safety category Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. •Application Overview • The power supply to the motor M is turned OFF when the S1 and S2 detect that the guard is opened. • The power supply to the motor M is kept OFF until the guard is closed and the reset switch S3 is pressed. Safety limit switch Limit switch Reset switch Magnetic contactor Motor

カタログの8ページ目を開く
G9SA - 9

G9SA-301 (100 to 240 VAC) with 2-channel Limit Switch Input/Auto-reset Highest achievable PL/ safety category Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. •Application Overview • The power supply to the motor M is turned OFF when the S1 and S2 detect that the guard is opened. • The power supply to the motor M is kept OFF until the guard is closed. Safety limit switch Limit switch Magnetic contactor Motor

カタログの9ページ目を開く
G9SA - 10

G9SA-301 (24 VAC/VDC) with 2-channel Emergency Stop Switch Input/Manual Reset Highest achievable PL/ safety category Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. •Application Overview • The power supply to the motor M is turned OFF when the emergency stop switch is pressed. • The power supply to the motor M is kept OFF until the reset switch S2 is pressed while the emergency stop switch is released. Timing Chart Emergency stop switch S1 Reset switch S2 KM1 and...

カタログの10ページ目を開く

OMRON/オムロンのすべてのカタログと技術パンフレット

  1. D4F

    8 ページ

  2. D4GS-N

    11 ページ

  3. E4E2

    5 ページ

  4. G9SE Series

    20 ページ

  5. NX-SL/SI/SO

    20 ページ

  6. G9SP

    28 ページ

  7. G9SX-SM

    24 ページ

  8. G9SX-SM/LM

    9 ページ

  9. G9SX/G9SX-GS

    49 ページ

  10. G9SX-LM

    28 ページ

  11. G9SB

    10 ページ

  12. DST1 Series

    5 ページ

  13. WS02-CFSC1-E

    3 ページ

  14. G9SA-300-SC

    9 ページ

  15. K8AK-AS

    12 ページ

  16. K8AK-AW

    16 ページ

  17. K8AK-VS

    12 ページ

  18. K8AK-VW

    12 ページ

  19. K8AK-PH

    12 ページ

  20. K8DS-PH

    12 ページ

  21. K8AK-PM

    16 ページ

  22. K8DS-PM

    12 ページ

  23. K8AK-PA

    12 ページ

  24. K8DS-PA

    12 ページ

  25. K8AK-PW

    12 ページ

  26. K8DS-PU

    12 ページ

  27. K8DS-PZ

    12 ページ

  28. K8AK-TS/PT

    12 ページ

  29. K8AK-LS

    12 ページ

  30. K8AK-TH

    12 ページ

  31. K2CM

    16 ページ

  32. SE

    15 ページ

  33. SAO

    13 ページ

  34. APR-S

    6 ページ

  35. XS5

    25 ページ

  36. XS2

    29 ページ

  37. F92A

    4 ページ

  38. GLS

    3 ページ

  39. TL-L

    5 ページ

  40. V680 series

    68 ページ

  41. V680S Series

    68 ページ

  42. MY

    35 ページ

  43. E3NC-L/-S

    16 ページ

  44. 61F-GPN-BT / -BC

    5 ページ

  45. NE1A-SCPU Series

    8 ページ

  46. NE1A-SCPU0[]-EIP

    8 ページ

  47. NE0A-SCPU01

    6 ページ

  48. LY

    14 ページ

  49. G2R-[]-S

    11 ページ

  50. G7T

    7 ページ

  51. G2A

    9 ページ

  52. G2A-434

    7 ページ

  53. G2AK

    7 ページ

  54. MK-S

    9 ページ

  55. MK-S(X)

    12 ページ

  56. MM

    17 ページ

  57. MMK

    14 ページ

  58. G4Q

    6 ページ

  59. G7Z

    9 ページ

  60. G7J

    10 ページ

  61. E4B

    12 ページ

  62. E4A-3K

    9 ページ

  63. E4C-UDA

    5 ページ

  64. E6H-C

    5 ページ

  65. E6F-C

    5 ページ

  66. E6D-C

    5 ページ

  67. E6B2-C

    5 ページ

  68. E6A2-C

    5 ページ

  69. NL

    8 ページ

  70. VB

    5 ページ

  71. SC

    5 ページ

  72. D5F

    5 ページ

  73. D5A

    8 ページ

  74. E3S-GS3E4

    3 ページ

  75. E3S-R

    11 ページ

  76. E3S-A

    21 ページ

  77. E3S-CL

    9 ページ

  78. E3ZM-C

    14 ページ

  79. E3T Data Sheet

    26 ページ

  80. E3T Series

    6 ページ

  81. G5 Series

    59 ページ

  82. Sysmac Catalog

    410 ページ

  83. VT-X700

    6 ページ

  84. E5AC-T

    8 ページ

  85. CP1

    12 ページ

  86. CP1E

    12 ページ

  87. MS4800

    40 ページ

  88. VC-DL100

    6 ページ

  89. FZ4 Series

    42 ページ

  90. ZG2

    16 ページ

  91. ZS Series

    32 ページ

  92. ZW Series

    24 ページ

  93. E9NC-T

    2 ページ

  94. CompoNet

    28 ページ

  95. Code Reader/OCR

    24 ページ

  96. NT series

    18 ページ

  97. Photomicro Sensors

    7 ページ

  98. H8PS Cam Positioner

    32 ページ

  99. FQ Vision Sensor

    17 ページ

  100. E2EF

    8 ページ

  101. FQ2 Smart camera

    24 ページ

カタログアーカイブ

  1. SMART REMOTE I/O

    12 ページ

  2. Sensor Accessories

    38 ページ

  3. REGULATION SOLUTIONS

    24 ページ

  4. Vision Systems

    20 ページ