For the most recent information on models that have been certified for safety standards, refer to your OMRON website. The G9SA Series Offers a Complete Line-up of Compact Units. • Four kinds of 45-mm wide Units are available: A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a Two-hand Controller. Also available are 17.5-mm wide Expansion Units with 3 poles and 3 OFF-delay poles. • Simple expansion connection. • OFF-delay models have 15-step OFF-delay settings. • Conforms to EN ISO13849-1 (PLe/Safety Category 4) *. • Both DIN track mounting and screw mounting are possible. * Except for some models. Refer to "Applicable Performance Level (PL)" on page 13, or "Reliability data for safety of control components_SISTEMA library" on OMRON's website. A Be sure to read the “Safety Precautions”on page 15 Model Number Structure Model Number Legend Note: 1. Please see “Ordering Information” on page 2 for the actual models that can be ordered. 2. Specify the power supply voltage when ordering. 1. Function None: Emergency stop EX: Expansion Unit 5. Input Configuration None: 1-channel or 2-channel input possible 6. OFF-delay Time (Max. setting time) None: No OFF-delay T075: 7.5 seconds T1 5: 15 seconds
カタログの1ページ目を開く
| Specify the power supply voltage when ordering. Emergency-stop Units Note: Set to maximum values in the factory.
カタログの2ページ目を開く
Power Input Item Model * When an Expansion Unit is connected, the power consumption is increased by 2 VA/2 W max. Inputs Item Model * When an Expansion Unit is connected, the input current is increased by 30 mA max. Contacts *1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method. *2. Not Including bounce time. *3. The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time. *4. The insulation resistance was measured with 500 VDC at the same places that the dielectric strength was checked. *5....
カタログの3ページ目を開く
Control circuit Control circuit Control circuit Control circuit Control circuit Control circuit Control circuit Control circuit Note: 1. With 100 to 240-VAC type, be sure to connect PE to a protective ground. With 24-VAC/VDC type, if the power supply is not connected to a protective ground, be sure to connect PE to a protective ground. 2. With 24-VAC/VDC type, the power supply terminals A1 and A2 have polarities. A2 is the negative pole. *1. Use terminals A and B to switch reset mode. A to B open: Manual reset A to B closed: Auto-reset *2. Terminal T23 is used for 2-channel input with a...
カタログの4ページ目を開く
*1. Terminal T23 Terminal T23 is used for 2-channel input with a positive common (when connecting a safety sensor with a PNP output). When T23 is being used, please open T21 and T22. For 1-channel input, short circuit T12-T23 before use. *2. Output Contacts G9SA-301: Safety Output Contacts 13-14, 23-24, 33-34. Auxiliary Contact 41-42. G9SA-501: Safety Output Contacts 13-14, 23-24, 33-34, 43-44, 53-54. Auxiliary Contact 61-62. G9SA-321-TQ Safety Output Contacts 13-14, 23-24, 33-34. Safety OFF-delay Output Contact 43-44, 53-54. Auxiliary Contact 61-62. *3. Terminals A and B A-B Opening:...
カタログの5ページ目を開く
Dimensions and Terminal Arrangement Twenty, M3 Twenty-four, M3 Twenty-four, M3 Twenty-one, M3 Connector cover * Note 1: The OFF-delay time setting switch is found on the G9SA-321-T@ only. 2: The K1 to K4 indicators light when the NO contacts of internal relays K1 to K4 close. * Do not remove unless an Expansion Unit is being used. PWR (green) K1 (green) K2 (green) OFF-delay time setting switch (See note 1) Note 1: The OFF-delay time setting switch is found on the G9SA-EX031-T@ only. 2: The K1 and K2 indicators light when the NO contacts of internal relays K1 and K2 close. OFF-delay time...
カタログの6ページ目を開く
Application ExamplesG9SA-301 (24 VAC/VDC) with 2-channel Limit Switch Input/Auto-reset Highest achievable PL/ safety category Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. •Application Overview • The power supply to the motor M is turned OFF when the S1 and S2 detect that the guard is opened. • The power supply to the motor M is kept OFF until the guard is closed. Timing Chart Limit switches S1 and S2 _ S1: Safety limit switch KM1 and KM2: Magnetic contactor...
カタログの7ページ目を開く
G9SA-301 (24 VAC/VDC) with 2-channel Limit Switch Input/Manual Reset Highest achievable PL/ safety category Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. •Application Overview • The power supply to the motor M is turned OFF when the S1 and S2 detect that the guard is opened. • The power supply to the motor M is kept OFF until the guard is closed and the reset switch S3 is pressed. Safety limit switch Limit switch Reset switch Magnetic contactor Motor
カタログの8ページ目を開く
G9SA-301 (100 to 240 VAC) with 2-channel Limit Switch Input/Auto-reset Highest achievable PL/ safety category Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. •Application Overview • The power supply to the motor M is turned OFF when the S1 and S2 detect that the guard is opened. • The power supply to the motor M is kept OFF until the guard is closed. Safety limit switch Limit switch Magnetic contactor Motor
カタログの9ページ目を開く
G9SA-301 (24 VAC/VDC) with 2-channel Emergency Stop Switch Input/Manual Reset Highest achievable PL/ safety category Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. •Application Overview • The power supply to the motor M is turned OFF when the emergency stop switch is pressed. • The power supply to the motor M is kept OFF until the reset switch S2 is pressed while the emergency stop switch is released. Timing Chart Emergency stop switch S1 Reset switch S2 KM1 and...
カタログの10ページ目を開くOMRON/オムロンのすべてのカタログと技術パンフレット
-
D4F
8 ページ
-
D4GS-N
11 ページ
-
E4E2
5 ページ
-
Fiber Unit E32-LT/LD
4 ページ
-
G9SE Series
20 ページ
-
NX-SL/SI/SO
20 ページ
-
G9SP
28 ページ
-
G9SX-SM
24 ページ
-
G9SX-SM/LM
9 ページ
-
G9SX/G9SX-GS
49 ページ
-
G9SX-LM
28 ページ
-
G9SB
10 ページ
-
DST1 Series
5 ページ
-
WS02-CFSC1-E
3 ページ
-
G9SA-300-SC
9 ページ
-
K8AK-AS
12 ページ
-
K8AK-AW
16 ページ
-
K8AK-VS
12 ページ
-
K8AK-VW
12 ページ
-
K8AK-PH
12 ページ
-
K8DS-PH
12 ページ
-
K8AK-PM
16 ページ
-
K8DS-PM
12 ページ
-
K8AK-PA
12 ページ
-
K8DS-PA
12 ページ
-
K8AK-PW
12 ページ
-
K8DS-PU
12 ページ
-
K8DS-PZ
12 ページ
-
K8AK-TS/PT
12 ページ
-
K8AK-LS
12 ページ
-
K8AK-TH
12 ページ
-
K2CM
16 ページ
-
SE
15 ページ
-
SAO
13 ページ
-
APR-S
6 ページ
-
XS5
25 ページ
-
XS2
29 ページ
-
F92A
4 ページ
-
GLS
3 ページ
-
TL-L
5 ページ
-
V680 series
68 ページ
-
V680S Series
68 ページ
-
MY
35 ページ
-
E3NC-L/-S
16 ページ
-
61F-GPN-BT / -BC
5 ページ
-
NE1A-SCPU Series
8 ページ
-
NE1A-SCPU0[]-EIP
8 ページ
-
NE0A-SCPU01
6 ページ
-
LY
14 ページ
-
G2R-[]-S
11 ページ
-
G7T
7 ページ
-
G2A
9 ページ
-
G2A-434
7 ページ
-
G2AK
7 ページ
-
MK-S
9 ページ
-
MK-S(X)
12 ページ
-
MM
17 ページ
-
MMK
14 ページ
-
G4Q
6 ページ
-
G7Z
9 ページ
-
G7J
10 ページ
-
E4B
12 ページ
-
E4A-3K
9 ページ
-
E4C-UDA
5 ページ
-
E6H-C
5 ページ
-
E6F-C
5 ページ
-
E6D-C
5 ページ
-
E6B2-C
5 ページ
-
E6A2-C
5 ページ
-
NL
8 ページ
-
VB
5 ページ
-
SC
5 ページ
-
D5F
5 ページ
-
D5A
8 ページ
-
E3S-GS3E4
3 ページ
-
E3S-R
11 ページ
-
E3S-A
21 ページ
-
E3S-CL
9 ページ
-
E3ZM-C
14 ページ
-
E3T Data Sheet
26 ページ
-
E3T Series
6 ページ
-
G5 Series
59 ページ
-
Sysmac Catalog
410 ページ
-
VT-X700
6 ページ
-
E5AC-T
8 ページ
-
CP1
12 ページ
-
CP1E
12 ページ
-
MS4800
40 ページ
-
VC-DL100
6 ページ
-
FZ4 Series
42 ページ
-
ZG2
16 ページ
-
ZS Series
32 ページ
-
ZW Series
24 ページ
-
E9NC-T
2 ページ
-
Vision System FH series
54 ページ
-
CompoNet
28 ページ
-
Code Reader/OCR
24 ページ
-
NT series
18 ページ
-
Safety Controller G9SP
28 ページ
-
Data Logger ZR-RX Series
12 ページ
-
DeviceNet Safety System
30 ページ
-
Switching Power Supplies
16 ページ
-
Photomicro Sensors
7 ページ
-
Displacement Sensors
4 ページ
-
H8PS Cam Positioner
32 ページ
-
FQ Vision Sensor
17 ページ
-
E2EF
8 ページ
-
FQ2 Smart camera
24 ページ
カタログアーカイブ
-
SMART REMOTE I/O
12 ページ
-
Sensor Accessories
38 ページ
-
REGULATION SOLUTIONS
24 ページ
-
Vision Systems
20 ページ