
カタログの抜粋

Smart Fiber Amplifier Units Sensor Communications Units Saving Space Start with Smart! Easily select the most reliable Fiber Unit for your detection conditions. Beam Improvements Standard Installation Fiber Units Selection Guide Fiber Sensor Best Selection Catalog Transparent Objects Best Selection Environmental Immunity Fiber Sensor Features Fiber Amplifiers, Technical Model Index Guide and Communications Installation Information Precautions Unit, and Accessories
カタログの1ページ目を開く
Fiber Sensor Fiber Sensor Features Optimal Fiber Sensor for additional Fiber Units for various Installation Conditions, Easy “Mounts Anywhere” Wide Variety Suitable for Harsh Environments Variously-shaped, compact heads allow installation in any small space. Fiber Units are available for various installation conditions and can be installed as is, even in harsh environments. “Achieve Easy Detection in Many Applications” Smart Tuning Automatic Setting of Optimum Values once with a workpiece and once without a workpiece Just press the button to set the optimum incident level and threshold....
カタログの2ページ目を開く
All in One Desk-top Navigation Fiber Sensor Best Selection Fiber Sensor Fiber Units for various Installation Conditions, installation when starting production. Fiber Sensor Features Fiber Sensor Features Optimal Fiber Sensor for additional Fiber Amplifier Units with easy optimum setting Easy “Mounts Anywhere” Wide Variety Suitable for Harsh Environments Variously-shaped, compact heads allow installation in any small space. Fiber Units are available for various installation conditions and can be installed as is, even in harsh environments. Fiber Units “Achieve Easy Detection in Many...
カタログの3ページ目を開く
Selection Guide Saving Space Standard Installation Fiber Units Selection Guide Fiber Sensor Features Beam Improvements Select a category. Fiber Unit Index Select a model. Category Pages 06 to 61 Select Accessories of Fiber Amplifier Unit Before Selecting Fiber Units Flat Sleeved Small Spot The Fiber Units specifications give the sensing distance when the Fiber Unit and Fiber Amplifier Unit is combined. Check the Fiber Amplifier Unit series for easier selection. Fiber Amplifier Unit Series High Power Transparent Objects Environmental Immunity Chemicalresistant, Oil-resistant Area Detection 1...
カタログの4ページ目を開く
Fiber Unit Index Cylindrical Models Flat Models Sleeve Models (Close-range Detection) Ideal for installation in narrow spaces. The Fiber Unit is secured with a set screw. Mount directly in limited spaces without using special mounting brackets. Suitable for close-range detection. Ideal for detecting minute objects in areas with limited space. Beam Improvements Small-Spot, Reflective (Minute Object Detection) High-power Beam (Long-distance Installation, Dust-resistant) Narrow View Detection without Background Interference (Detection Across Clearance) Flat Sleeved Saving Space Standard...
カタログの5ページ目を開く
Standard Installation Threaded Models Through-beam → This Page Threaded Models Installation Information → 59 ,60 Page Through-beam Fiber Units (Set of 2) 07-A E32-T11N 2M (Free Cutting) 8.4 dia. Model display tube Selection Guide Selection Guide • Standard configuration. These Fiber Units are mounted into a hole drilled in a bracket and secured with nuts. • The Right-angle Model prevents snagging on the cable because the cable runs along the mounting surface. 07 Fiber Sensor Features Standard Installation Fiber Sensor Features Bending radius of cable E3X-HD GIGA HS Other modes High Power...
カタログの6ページ目を開く
Standard Installation Threaded Models Through-beam → This Page Threaded Models Installation Information → 59 ,60 Page Through-beam Fiber Units (Set of 2) 07-A E32-T11N 2M (Free Cutting) 8.4 dia. Model display tube Selection Guide Selection Guide • Standard configuration. These Fiber Units are mounted into a hole drilled in a bracket and secured with nuts. • The Right-angle Model prevents snagging on the cable because the cable runs along the mounting surface. 07 Fiber Sensor Features Standard Installation Fiber Sensor Features Bending radius of cable E3X-HD GIGA HS Other modes High Power...
カタログの7ページ目を開く
Standard Installation Threaded Models Fiber Sensor Features Saving Space Standard Installation Fiber Units Selection Guide • Standard configuration. These Fiber Units are mounted into a hole drilled in a bracket and secured with nuts. • The Right-angle Model prevents snagging on the cable because the cable runs along the mounting surface. Beam Improvements Top-view Type Threaded Right-angle Type Flat Sleeved Small Spot High Power Reflective Fiber Units Sensing direction (Aperture angle) Sensing distance (mm) Size Bending radius of cable Chemicalresistant, Oil-resistant Area Detection...
カタログの8ページ目を開く
Standard Installation Threaded Models Reflective → This Page Installation Information → 58 ,59 Page Reflective Fiber Units 09-E E32-C31M 1M (Free Cutting) Opposite side 5.5, thickness 1.8 (Nickel-plated brass) Washer (Nickel-plated brass) 1 dia. emission fibers Note: There is a white line on the emitter fiber. M3 nuts (Nickel-plated brass) Washer (Nickel-plated brass) provided (2 of each) Model display tube Sixteen, 0.265 dia. receiver fibers Chemicalresistant, Oil-resistant Note: There is a white line on the emitter fiber. Note: There is a white line on the emitter fiber. E32-LD11 2M (Free...
カタログの9ページ目を開く
Standard Installation Cylindrical Models Fiber Sensor Features Through-beam → This Page • Inserted where space is limited. (Secured using a set screw.) • Ultramate space-saving by micro-fiber head. (1 dia. × 10 mm) Selection Guide secured with a set screw Saving Space Standard Installation Fiber Units Threaded Cylindrical Flat Sleeved Through-beam Fiber Units Beam Improvements High Power Narrow view Sensing distance (mm) Size Sensing direction Transparent Objects Bending Heatresistant Area Detection Liquid-level Vacuum FPD, Semi, Solar Fiber Amplifiers, Technical Communications Model Index...
カタログの10ページ目を開く
Cylindrical Models Dimensions Installation Information → 60 Page Through-beam Fiber Units (Set of 2) 1 dia. (Stainless steel) Fiber Units 11-B E32-T22B 2M (Free Cutting) Sensing surface 0.5 dia. Cylindrical 11-C E32-T12R 2M (Free Cutting) Sensing surface 1 dia. Standard Installation Saving Space Selection Guide 11 Fiber Sensor Features Standard Installation High Power Heat-shrinkable tube Narrow view Retroreflective Limitedreflective Chemicalresistant, Oil-resistant Bending Heatresistant Transparent Objects Environmental Immunity Beam Improvements Small Spot Liquid-level Vacuum Area...
カタログの11ページ目を開くOMRON/オムロンのすべてのカタログと技術パンフレット
-
D4F
8 ページ
-
D4GS-N
11 ページ
-
E4E2
5 ページ
-
Fiber Unit E32-LT/LD
4 ページ
-
G9SE Series
20 ページ
-
NX-SL/SI/SO
20 ページ
-
G9SP
28 ページ
-
G9SX-SM
24 ページ
-
G9SX-SM/LM
9 ページ
-
G9SX/G9SX-GS
49 ページ
-
G9SX-LM
28 ページ
-
G9SB
10 ページ
-
G9SA
16 ページ
-
DST1 Series
5 ページ
-
WS02-CFSC1-E
3 ページ
-
G9SA-300-SC
9 ページ
-
K8AK-AS
12 ページ
-
K8AK-AW
16 ページ
-
K8AK-VS
12 ページ
-
K8AK-VW
12 ページ
-
K8AK-PH
12 ページ
-
K8DS-PH
12 ページ
-
K8AK-PM
16 ページ
-
K8DS-PM
12 ページ
-
K8AK-PA
12 ページ
-
K8DS-PA
12 ページ
-
K8AK-PW
12 ページ
-
K8DS-PU
12 ページ
-
K8DS-PZ
12 ページ
-
K8AK-TS/PT
12 ページ
-
K8AK-LS
12 ページ
-
K8AK-TH
12 ページ
-
K2CM
16 ページ
-
SE
15 ページ
-
SAO
13 ページ
-
APR-S
6 ページ
-
XS5
25 ページ
-
XS2
29 ページ
-
F92A
4 ページ
-
GLS
3 ページ
-
TL-L
5 ページ
-
V680 series
68 ページ
-
V680S Series
68 ページ
-
MY
35 ページ
-
E3NC-L/-S
16 ページ
-
61F-GPN-BT / -BC
5 ページ
-
NE1A-SCPU Series
8 ページ
-
NE1A-SCPU0[]-EIP
8 ページ
-
NE0A-SCPU01
6 ページ
-
LY
14 ページ
-
G2R-[]-S
11 ページ
-
G7T
7 ページ
-
G2A
9 ページ
-
G2A-434
7 ページ
-
G2AK
7 ページ
-
MK-S
9 ページ
-
MK-S(X)
12 ページ
-
MM
17 ページ
-
MMK
14 ページ
-
G4Q
6 ページ
-
G7Z
9 ページ
-
G7J
10 ページ
-
E4B
12 ページ
-
E4A-3K
9 ページ
-
E4C-UDA
5 ページ
-
E6H-C
5 ページ
-
E6F-C
5 ページ
-
E6D-C
5 ページ
-
E6B2-C
5 ページ
-
E6A2-C
5 ページ
-
NL
8 ページ
-
VB
5 ページ
-
SC
5 ページ
-
D5F
5 ページ
-
D5A
8 ページ
-
E3S-GS3E4
3 ページ
-
E3S-R
11 ページ
-
E3S-A
21 ページ
-
E3S-CL
9 ページ
-
E3ZM-C
14 ページ
-
E3T Data Sheet
26 ページ
-
E3T Series
6 ページ
-
G5 Series
59 ページ
-
Sysmac Catalog
410 ページ
-
VT-X700
6 ページ
-
E5AC-T
8 ページ
-
CP1
12 ページ
-
CP1E
12 ページ
-
MS4800
40 ページ
-
VC-DL100
6 ページ
-
FZ4 Series
42 ページ
-
ZG2
16 ページ
-
ZS Series
32 ページ
-
ZW Series
24 ページ
-
E9NC-T
2 ページ
-
Vision System FH series
54 ページ
-
CompoNet
28 ページ
-
Code Reader/OCR
24 ページ
-
NT series
18 ページ
-
Safety Controller G9SP
28 ページ
-
Data Logger ZR-RX Series
12 ページ
-
DeviceNet Safety System
30 ページ
-
Switching Power Supplies
16 ページ
-
Photomicro Sensors
7 ページ
-
Displacement Sensors
4 ページ
-
H8PS Cam Positioner
32 ページ
-
FQ Vision Sensor
17 ページ
-
E2EF
8 ページ
-
FQ2 Smart camera
24 ページ
カタログアーカイブ
-
SMART REMOTE I/O
12 ページ
-
Sensor Accessories
38 ページ
-
REGULATION SOLUTIONS
24 ページ
-
Vision Systems
20 ページ