カタログの抜粋

MAXIFLEX Remote I/O Link Module Model M1593A Remote I/O Conet Link Network Interface Module Expand I/O to Maxiflex Systems to 1000 I/O Connect Remote I/O to Maxiflex CPU’s up to 10km away Implement Dual Redundant Control Systems Connect up to 3 additional Remote Slave I/O Bases The M1593A Remote I/O Conet Link (RIOc) Module allows up to three Maxiflex remote I/O Bases to be connected to a Maxiflex Master Base. The Remote I/O Bases can be located in the same panel, or up to 10km away. The M1593A RIOc module fits into any I/O slot of a Maxiflex Master Base, and connects to up to 3 Maxiflex M1248A R2c Remote I/O Processors. Each Remote I/O Processor can scan up to 15 I/O modules. This Maxiflex RIOc Module is designed to operate in conjunction with a Maxiflex T3 or P3 Maxiflex CPU module in the Master System. The RIOc module scans the I/O from the remote bases and transfers the I/O data into the T3 or P3 CPU’s Data Interchange Table for program or SCADA access. The data link to the Maxiflex R2c modules operates on the Conet data highway, providing an event-driven token-passing ruggedised industrial network capable of running up to 10km. This allows remote I/O Bases to be placed in the same panel as the Master Controller, or distributed across the site. Create Maxiflex Systems larger than 15 I/O modules using remote I/O Processors. Up to three additional Maxiflex Bases can be integrated as Remote I/O into a Master Maxiflex System allowing systems up to 2000 I/O to be created. Construct dual redundant CPU applications with shared I/O. By combining this Maxiflex RIOc module with the Maxiflex P3-R or T3-R redundant CPU’s, dual redundant CPU configurations can be constructed with shared I/O. Copyright Omniflex ♦ Subject to change without notice
カタログの1ページ目を開く
MAXIFLEX Remote I/O Link Module Model M1593A Remote I/O Conet Link Network Interface Module Specifications Conet Communications Port On = data is being transmitted Conet Network Interface On = Data is being received Baud Rate 62,500 baud (Normal) or 7,800 baud (Slow) Environmental Operating Temperature Maximum cable length Up to 10km depending upon cable type and baud rate. Storage Temperature Electronics conformal coated Cable Type Can operate over most conventional cables (twisted or not), but optimum distance of 10km is achieved with RS485 grade twisted pair cable. Logic Power...
カタログの2ページ目を開く
MAXIFLEX Remote I/O Link Module Model M1593A Remote I/O Conet Link Network Interface Module Typical Remote I/O Configuration Copyright Omniflex ♦ Subject to change without notice
カタログの3ページ目を開く
MAXIFLEX Remote I/O Link Module Model M1593A Remote I/O Conet Link Network Interface Module Typical Redundant System Configuration Ethernet SCADA Network Secondary Controller Primary Controller Controller Link Copyright Omniflex ♦ Subject to change without notice
カタログの4ページ目を開くOmniflexのすべてのカタログと技術パンフレット
-
MAXIFLEX Bases
3 ページ
-
Model M1265A CPU A3e
8 ページ
-
Model M1711A HSC
2 ページ
-
Model M1322A 16DI-24
2 ページ
-
Model M1323A 16DI-48
2 ページ
-
Model M1326A 32DI-24
2 ページ
-
Model M1327A 64DI-24
2 ページ
-
Model M1341B 16DO
2 ページ
-
Model M1330A 8DI8RO
2 ページ
-
Model M1342A 32DO
2 ページ
-
Model M1372A 8RO
2 ページ
-
Maxilarm
15 ページ
-
Model C2330B-11-0
6 ページ
-
Model C2330B-12-0
6 ページ
-
Model M1403A 16AI
2 ページ
-
Model M1412A 8AO
2 ページ
-
C2404B
4 ページ
-
C118xB series
4 ページ
-
Model M1240B CPU T2
6 ページ
-
Model M1022B BASE
3 ページ
-
Model M1102A PSU
2 ページ
-
Model M1023B BASE
3 ページ
-
Model M1021B BASE
3 ページ
-
Model C2462A OT LPD
12 ページ