High Accuracy Automated Temperature Calibration
1 / 5ページ

{{requestButtons}}

カタログの抜粋

High Accuracy Automated Temperature Calibration - 1

High Accuracy Automated Temperature Calibration CL543B U Calibrate Thermocouple Instruments to 0.1 and 0.01, °F and °C • ypes J, K, T, E, R, S, B, N, T G, C, D, L (J-DIN), U (T-DIN) and P (Platinel): -13.000 to 80.000 mV U alibrate RTD Instruments to C 0.1 and 0.01, °F and °C • t 10, 50, 100, 200, 500 and P 1000Ω (3850) • t 100Ω (alpha = 3902, P 3916, 3926) • Cu 10 and 50Ω and Ni 120Ω U alibrate with Confidence C • esolution to 0.01, °F and °C; R Accurate to 0.2° • old Junction Sensor C Accurate to 0.05°C • IST Traceable Cold Junction N Sensor in Isothermal Block U erform Heat Treating P Surveys and Accuracy Tests • eets or Exceeds the M Requirement of AMS 2750 as Both a Secondary Standard Instrument and as a Field Test Instrument U roubleshoot RTD Sensors T and Instruments • utomatic Detection of 2-, A 3- or 4-Wire Connections Indicates When Individual Wire Connections are Open • erify Proper Instrument V Operation by Measuring the Excitation Current U ast Easy Calibrations F • nstantly Select 3 Outputs I with the EZ-CHECK Switch • asily Find Trip Points with E 2 Speed EZ-DIAL Knob and Automatic Stepping U asily Change Thermocouple E Types and Scale • ouble Click to Select D Thermocouple Type, °F and °C Shop • ncludes Rubber Boot and mV I Test Leads • ow Profile Switches Resist L Accidental Damage • rass Screws for B Thermocouple Wires Plus Miniature Thermocouple Socket U Easy-to-Read Display • Backlight Ideal for Dark Areas U Simple “No Tool” Battery Changes • “AA” Batteries Included 4 U erify Resistance, Cold V Junction Temperature and Output • econdary Display of S Resistance for RTDs and Compensated millivolt Setting, and Cold Junction Temperature for Thermocouple U Secondary Display • hows millivolts and Cold S Junction Temperature While Displaying Thermocouple Temperature, and Shows Ohms while Displaying RTD Temperature U IST Cert (No Points) N CL543B shown smaller than actual size. THERMOCOUPLE CONNECTIONS Simulating or reading thermocouples requires the use of thermocouple or extension grade thermocouple wire. Plug thermocouple wires into the miniature thermocouple jack or place bare thermocouple wires onto the brass block under the screws. The CL543B has two banana jacks (1+ and 2-) mounted in the top end of the housing. These are not temperature compensated and are to be used only for millivolt signals. 1 Screw terminal for thermocouple wire plus miniature thermocouple

カタログの1ページ目を開く
High Accuracy Automated Temperature Calibration - 2

Specifications Operating Temperature Range: -20 to 60°C (-5 to 140°F) Storage Temperature Range: -30 to 60°C (-22 to 140°F) Temperature Effect: ≤±25 ppm/°C of range Cold Junction Sensor: ≤±0.01% °/° from ambient temperature (°C or °F) Relative Humidity Range: 10% ≤RH ≤90% (0 to 35°C), non-condensing 10% ≤RH ≤70% (35 to 60°C), non-condensing Normal Mode Rejection: 50/60 Hz, 50 dB Common Mode Rejection: 50/60 Hz, 120 dB Dimensions: 143 L x 76 W x 41 mm H (5.63 x 3 x 1.60") Weight: 0.34 kg (12.1 oz) with boot and batteries Batteries: Four “AA” alkaline 1.5V (LR6) (included), optional NiMh...

カタログの2ページ目を開く
High Accuracy Automated Temperature Calibration - 3

Thermocouples Ranges and Accuracies Table Based on Accuracy: ≤±(0.008% of reading + 0.006 mV) Note: Doesn’t include cold junction error of ±0.05°C Thermocouple Type +Chromel -Constantan +Copper -Constantan

カタログの3ページ目を開く
High Accuracy Automated Temperature Calibration - 4

Thermocouples Ranges and Accuracies Table Based on Accuracy: ≤±(0.008% of reading + 0.006 mV) Note: Doesn’t include cold junction error of ±0.05°C Thermocouple Type Thermocouple Material +Iron -Constantan +Copper -Constantan Table Based on 3 & 4 Wire RTD Accuracy: ≤±(0.015% of reading +0.05Ω) [read based on 1.0 mA of fixed excitation current] RTD Type

カタログの4ページ目を開く
High Accuracy Automated Temperature Calibration - 5

Table Based on 3 & 4 Wire RTD Accuracy: ≤±(0.015% of reading +0.05Ω) [read based on 1.0 mA of fixed excitation current] RTD Type Thermocouple and RTD temperature calibrator Comes complete with 4 “AA” alkaline batteries, NIST Cert (no points), rubber boot, deluxe hands free carrying case, mA/V test leads, 1 red and 1 black lead with banana plugs and alligator clips, RTD wire kit, 2 red and 2 black leads with banana plugs and spade lugs, and operator’s manual. Ordering Example: CL543B, thermocouple and RTD temperature calibrator with calibration certificate. Extended Warranty Program...

カタログの5ページ目を開く

OMEGA/オメガのすべてのカタログと技術パンフレット

  1. WTS Series

    4 ページ

  2. DPG280

    2 ページ

  3. OMPBD7 series

    6 ページ

  4. BEAKER HEATERS

    1 ページ

  5. OM-CP-SHOCK-SERIES

    2 ページ

  6. EZ-VIEW FLOWMETERS

    1 ページ

  7. Model H

    1 ページ

  8. MICRO-FLOW METER

    1 ページ

  9. HHAQ-104

    1 ページ

  10. DOTX441

    1 ページ

  11. DOCN600 Series

    2 ページ

  12. TXDIN1600s

    2 ページ

  13. M12

    1 ページ

  14. AHPF Series

    1 ページ

  15. RFH Series

    2 ページ

  16. HHM10

    6 ページ

  17. OMEGA RTD BROCHURE

    32 ページ

  18. iDRN/iDRX Series

    9 ページ

  19. RDXL8

    2 ページ

  20. HHWT-12 Series

    2 ページ

  21. FD-400 Series

    4 ページ

  22. OM-DAQPRO-5300

    4 ページ

  23. M12-TC-SL Series

    1 ページ

  24. OS-MINIHUB

    4 ページ

  25. RHCM-40-PL-P

    2 ページ

  26. OS-MINIUSB-SN21

    2 ページ

  27. OSAT-151-C-LT-5

    2 ページ

  28. CSMSTRSX, CSMSTRGT

    3 ページ

  29. CSMSTRLE

    3 ページ

  30. AU-PTV Series

    3 ページ

  31. ADAM-5000

    7 ページ

  32. KE Series

    1 ページ

  33. SRM Series

    3 ページ

  34. SRL Series

    3 ページ

  35. PHH-SD1

    2 ページ

  36. CDH-5020 Series

    1 ページ

  37. PHH222

    1 ページ

  38. PHH224

    1 ページ

  39. PHH720

    1 ページ

  40. PHH830

    2 ページ

  41. PHH-126

    1 ページ

  42. PHH-127

    1 ページ

  43. PHH-128

    1 ページ

  44. PHH-37

    1 ページ

  45. PHH-715

    2 ページ

  46. PHH103B

    1 ページ

  47. BB-5

    2 ページ

  48. BB-2A

    2 ページ

  49. CA 150

    5 ページ

  50. CL 110

    2 ページ

  51. CL 1600

    2 ページ

  52. CL 1201

    2 ページ

  53. CL 355A

    2 ページ

  54. FL 500

    2 ページ

  55. FL 500WW

    2 ページ

  56. FL-X

    2 ページ

  57. FPR 100

    3 ページ

  58. FL6100SS-7900SS

    2 ページ

  59. FSW500

    2 ページ

  60. FSW 420- 430

    2 ページ

  61. CL 1500 Series

    3 ページ

  62. CDTX90

    6 ページ

  63. FSW 6000-7000

    3 ページ

  64. DRP 8500

    3 ページ

  65. DP 3300

    2 ページ

  66. DP119

    1 ページ

  67. HE-X Series

    3 ページ

  68. HE359 Series

    3 ページ

  69. RD4

    2 ページ

  70. DPi

    3 ページ

  71. HH311

    2 ページ

  72. MP1

    1 ページ

  73. HFS

    2 ページ

  74. CO

    2 ページ

  75. WT

    2 ページ

カタログアーカイブ

  1. Thermowells FTW

    1 ページ

  2. 6M Series

    2 ページ