Handheld Data Logging Meter with SD Card
1 / 1ページ

カタログの抜粋

Handheld Data Logging Meter with SD Card - 1

Handheld Data Logging Meter with SD Card For Measuring Conductivity, TDS, Salt Concentration, pH, ORP and DO HHWT-SD1 Conductivity/ TDS/salt probe (included). U issolved Oxygen Measurements can D be Compensated for Salt, Altitude and Temperature U easures Oxygen Content of a Volume of Air M U Optional ATC for pH Compensation U Records Maximum and Minimum Readings U erforms Real-Time Automatic Data Logging P U Sampling Time Settable from 1 Sec to 9 Hrs U Large Easy-to-Read Green Backlit LCD U Auto Power-Off Function The HHWT-SD1 is a general purpose handheld instrument capable of measuring the pH, Oxidation-Reduction Potential (ORP) or conductivity of a solution, as well as its TDS (Total Dissolved Solids), DO (Dissolved Oxygen) or salt content. Using the included conductivity/TDS/salt probe, an optional DO probe, and optional ORP or pH electrodes the meter can measure pH from 0 to 14, ORP from -1999 mV to 1999 mV, conductivity up to 200 mS (milliSiemens), TDS up to 132,000 ppm, DO up to 20 mg/L, and salt content up to 12% by weight. The HHWT-SD1 is designed for water conditioning, wastewater monitoring, beverage production, aquaculture (fish farming), aquariums, pulp and paper processing, electroplating, and photography applications. A front-panel pushbutton enables rapid switching among the meter’s four measurement modes. Because it is microprocessor-based, the HHWT-SD1 is portable, reliable and has the large storage capacities that SD memory cards offer. Measurements can be made automatically at any sampling rate between one second and nine hours. After time-stamping and storing the measurements on an SD card plugged into the meter, the user can remove the card and plug it into to a computer either directly or via a USB card reader. The values are stored on the card as files with the .xls extension, which can be opened by Microsoft’s Excel® application. Display Size: 52 x 38 mm (2.05 x 1.5") Measurement Range: pH: 0 to 14 (probe sold separately) ORP: -1999 to 1999 mV (probe sold separately) Conductivity: Up to 200 mS (microSiemens) TDS: Up to 132,000 ppm DO: Up to 20 mg/L (probe sold separately) Salt: Up to 12% by weight Measurement Accuracy: pH: ±(0.02 pH units + 2 digits) (probe sold separately) ORP: ±(0.5% of reading + 2 digits) (probe sold separately) Conductivity: ±2% of full-scale reading + 1 digit TDS: ±2% of full-scale reading + 1 digit Temperature: ±0.8°C/±1.5°F 2 GB SD memory card included. DO: ±0.4 mg/L in solution (probe sold separately) Oxygen: 0.1% for oxygen in air (probe sold separately) Salt: ±0.5% of value Temperature Compensation: Automatic between 0 and 65°C (32 and 150°F) with optional ATC temperature probe. Manually settable between 0 and 100°C (32 and 212°F) without ATC probe Settable Parameters: Date, time, auto power off, beep sound, sampling time, decimal point or comma decimal division, temperature unit, compensation temperature. Also salt and altitude compensation (DO mode only) Operating Temperature: 0 to 50°C (32 to 122°F) Meter Dimensions: 135 H x 60 W x 33 mm D (5.31 x 2.36 x 1.30") Weight: 35 oz (2.19 lb) Handheld SD data logging water test meter Optional AC adaptor Optional ATC temperature probe Optional DO laboratory electrode Optional ORP laboratory electrode Optional pH laboratory electrode pH 4 buffer solution pH 7 buffer solution pH 10 buffer solution 1413 microSiemen conductivity solution Comes complete with meter, combination conductivity/TDS/salt probe, hard carrying case, 2 GB SD memory card and operaror’s manual (solutions sold separately). Ordering Example: HHWT-SD1, data logging water test meter with PHE-1311, pH electrode and PHA-4, pH 4 b

カタログの1ページ目を開く

OMEGA/オメガのすべてのカタログと技術パンフレット

  1. WTS Series

    4 ページ

  2. DPG280

    2 ページ

  3. OMPBD7 series

    6 ページ

  4. BEAKER HEATERS

    1 ページ

  5. OM-CP-SHOCK-SERIES

    2 ページ

  6. EZ-VIEW FLOWMETERS

    1 ページ

  7. Model H

    1 ページ

  8. MICRO-FLOW METER

    1 ページ

  9. HHAQ-104

    1 ページ

  10. DOTX441

    1 ページ

  11. DOCN600 Series

    2 ページ

  12. TXDIN1600s

    2 ページ

  13. M12

    1 ページ

  14. AHPF Series

    1 ページ

  15. RFH Series

    2 ページ

  16. HHM10

    6 ページ

  17. OMEGA RTD BROCHURE

    32 ページ

  18. iDRN/iDRX Series

    9 ページ

  19. RDXL8

    2 ページ

  20. HHWT-12 Series

    2 ページ

  21. FD-400 Series

    4 ページ

  22. OM-DAQPRO-5300

    4 ページ

  23. M12-TC-SL Series

    1 ページ

  24. OS-MINIHUB

    4 ページ

  25. RHCM-40-PL-P

    2 ページ

  26. OS-MINIUSB-SN21

    2 ページ

  27. OSAT-151-C-LT-5

    2 ページ

  28. CSMSTRSX, CSMSTRGT

    3 ページ

  29. CSMSTRLE

    3 ページ

  30. AU-PTV Series

    3 ページ

  31. ADAM-5000

    7 ページ

  32. KE Series

    1 ページ

  33. SRM Series

    3 ページ

  34. SRL Series

    3 ページ

  35. PHH-SD1

    2 ページ

  36. CDH-5020 Series

    1 ページ

  37. PHH222

    1 ページ

  38. PHH224

    1 ページ

  39. PHH720

    1 ページ

  40. PHH830

    2 ページ

  41. PHH-126

    1 ページ

  42. PHH-127

    1 ページ

  43. PHH-128

    1 ページ

  44. PHH-37

    1 ページ

  45. PHH-715

    2 ページ

  46. PHH103B

    1 ページ

  47. BB-5

    2 ページ

  48. BB-2A

    2 ページ

  49. CA 150

    5 ページ

  50. CL 110

    2 ページ

  51. CL 1600

    2 ページ

  52. CL 1201

    2 ページ

  53. CL 355A

    2 ページ

  54. FL 500

    2 ページ

  55. FL 500WW

    2 ページ

  56. FL-X

    2 ページ

  57. FPR 100

    3 ページ

  58. FL6100SS-7900SS

    2 ページ

  59. FSW500

    2 ページ

  60. FSW 420- 430

    2 ページ

  61. CL 1500 Series

    3 ページ

  62. CDTX90

    6 ページ

  63. FSW 6000-7000

    3 ページ

  64. DRP 8500

    3 ページ

  65. DP 3300

    2 ページ

  66. DP119

    1 ページ

  67. HE-X Series

    3 ページ

  68. HE359 Series

    3 ページ

  69. RD4

    2 ページ

  70. DPi

    3 ページ

  71. HH311

    2 ページ

  72. MP1

    1 ページ

  73. HFS

    2 ページ

  74. CO

    2 ページ

  75. WT

    2 ページ

カタログアーカイブ

  1. Thermowells FTW

    1 ページ

  2. 6M Series

    2 ページ