OHM(Chongqing)Electronics Technology CO.,LTD. Quality Assurance OHM (Chongqing) Electronics Technology CO., LTD. (hereinafter referred to as OHM) warrants that the product completely conforms to various technical parameters listed in the instructions at delivery and that it can be able to normally function as long as it is correctly installed and operated as required. Warranty Commitment This product has a one -year warranty period from the date of delivery. The company promises to make repairs when any damage or fault that is not caused by human factors occurs during the warranty period....
カタログの2ページ目を開く
OHM(Chongqing)Electronics Technology CO.,LTD. Pictographs Danger due to electrical voltage. Touching live parts inside the unit can be fatal or cause serious injuries. Instructions for occupational health and safety. Not following these instructions can cause accidents, which can cause damage, serious injuries or even death. Important information about the operation of the radio syst
カタログの3ページ目を開く
OHM(Chongqing)Electronics Technology CO.,LTD. Read through these operating instructions carefully before working with the radio control system. As an integral part of the radio control system, the operating instructions shall be always kept by specially-assigned personnel. The term “machine” used in the operating instructions refers to various equipment controlled by the radio control system in general; The radio control system is used to control machines and for data transfer. Observe the job safety and accident prevention regulations applicable to each application. The use also includes...
カタログの4ページ目を開く
OHM(Chongqing)Electronics Technology CO.,LTD. Do not leave the radio remote control transmitter system switched on unattended. Always switch the radio transmitter off when it is not required. This applies in particular if you change location, when working without radio control, during breaks and at the end of work. Always safeguard the radio transmitter against use by unauthorized persons, for example by locking it away. In the event of an emergency or a fault of the crane or machine, make sure to immediately press the emergency stop switch on the transmitter. Only operate the radio...
カタログの5ページ目を開く
OHM(Chongqing)Electronics Technology CO.,LTD. Always check the housing and push-buttons of the transmitter. In case of damage is found, immediately replace it. Always pay attention to and check voltage of the transmitter; in case of no power or insufficient the voltage, immediately replace the battery. In case of any abnormal condition, immediately press the emergency stop switch. In case of temporary disuse or end of the operation, press the emergency stop switch. Do not use 2 (or more) transmitters to operate the same equipment at the same time. Do not use the same frequency within the...
カタログの6ページ目を開く
OHM(Chongqing)Electronics Technology CO.,LTD. Mounting holes 3. System Settings 3.1 Frequency and Address Code Settings The frequency and address codes are stored in the system's ADCON and need to be set by professionals using special tools. 3.2 Bus Communication Settings The DIP switch in the left image below shows the address setting switch, while the switch in the right image displays the baud rate setting switch. For details, refer to the bus information table.
カタログの7ページ目を開く
OHM(Chongqing)Electronics Technology CO.,LTD. 4. Receiver Operation 4.1 Receiver Installation 4.1.1 Precautions Ensure that no other remote controllers are operating at the same frequency within a 300-meter radius. Verify the proper functioning of the controlled equipment. Ensure that the voltage at the installation site matches that of the receiver before turning off the main power. Determine the wiring method according to the provided diagrams. If cable glands are used, plug any unused ones securely. Select a suitable location for installation: Choose a position that allows the...
カタログの8ページ目を開く
OHM(Chongqing)Electronics Technology CO.,LTD. 4.2 Receiver Status Indicator Lights Through the receiver's status indicator light window, the working status of the receiver can be observed. ON: Power Indicator SQ: RF Signal Indicator SI: Signal Indicator OK: Status Indicator Power Indicator Light (ON): A steady green LED light indicates that the receiver is powered on and functioning correctly. RF Signal Indicator Light (SQ): A steady red LED light indicates that the transmitter is not connected to the receiver, while the off state of the red light indicates a successful connection. Signal...
カタログの9ページ目を開く
OHM (Chongqing) Electronics Technology CO., LTD. version: 2023.08 TCT-A12 operating manual page 7/9
カタログの10ページ目を開く
OHM(Chongqing)Electronics Technology CO.,LTD. Regularly check the function of the emergency stop switch to ensure that the emergency stop switch is kept in normal working status. Keep the battery contacts clean. When a rechargeable battery is used, ensure the battery is fully charged for the first use; the battery not used for a long time shall be stored under normal temperature and shall be charged regularly, to prevent battery damages caused by self-discharge (it is recommended that the battery is charged once per 6 months) If the radio control system is not used for a long time, take its...