カタログの抜粋

od*t Sichuan Odot Automation System Co., Ltd
カタログの1ページ目を開く
od*t Sichuan Odot Automation System Co., Ltd CANopen to Modbus TCP protocol converter ODOT Automation System Co., Ltd. 2015-5 Copyright ©2019 ODOT Automation all rights reserved
カタログの2ページ目を開く
od*t Sichuan Odot Automation System Co., Ltd Version information The following changes have been made to the document: Ownership rights information Without the permission of the copyright owner, all or part of this document shall not be republished as a paper or electronic document. Disclaimer This document is only intended to assist the reader in using the products, and the company shall not be responsible for any loss or error caused by the use of the information in this document. The product and text described in this document are under constant development and refinement. ODOT...
カタログの3ページ目を開く
od*t Sichuan Odot Automation System Co., Ltd Software download Please log on the official website: www.odotautomation.com and click on the corresponding product page to download.
カタログの4ページ目を開く
http:// www.odotautomation.com
カタログの5ページ目を開く
1. Product Overview 1.1 Product Functions MG-CANEX is a protocol converter from CANopen to Modbus TCP. The device plays as the master in the CANopen network and it could be connected to the standard CANopen slave devices. The data transmission http:// www.odotautomation.com
カタログの6ページ目を開く
OCM Sichuan Odot Automation System Co., Ltd supports PDO, SDO, and error control supports Heartbeat. It Supports synchronous and asynchronous message sending. As a TCP server in Modbus TCP network, the device could be accessed by 5 TCP clients at the same time, and it could be connected to PLC controller and various kinds of configuration software. It could also connect optical transceiver and to realize long-distance data transmission. 1.2 Functional characteristics ♦ The gateway comes with its own configuration software, and the parameter configuration information is downloaded to the...
カタログの7ページ目を開く
od*t Sichuan Odot Automation System Co., Ltd x05, 0 x06, 0 x0F, 0 x10. ♦ 6KB large data buffer, more data transfer volume. ♦ CAN interface supports CANopen working mode. ♦ CAN interface Baud rate: 10K~1Mbps. ♦ CANopen protocol conforms to DS301 V4.02 and supports NMT master, PDO, SDO and Heartbeat. ♦ It supports one-key reset function to restore factory Settings. ♦ 35mm DIN-rail installation. ♦ EMC meets EN 55022:2010 & EN55024:2010 international standards. 1.3 Technical parameters The technical parameters of this product are shown in Table 1. Please use this product within the parameters...
カタログの8ページ目を開く
od*t Sichuan Odot Automation System Co., Ltd Tablel. Technical parameters
カタログの9ページ目を開く
od*t Sichuan Odot Automation System Co., Ltd 2.2 Indicator light description The equipment has 6 LED status indicator lights, whose symbol definition and status description are shown in "Table 2". Table 2. Indicator light instructions
カタログの10ページ目を開く
od*t Sichuan Odot Automation System Co., Ltd
カタログの11ページ目を開く
od*t Sichuan Odot Automation System Co., Ltd Table 3. terminal definition 2.4 System reset The device has a system RESET button, which can be triggered when the user forgets the IP address and configured port No. of the device and could not connect to the gateway. System parameters will be restored to factory Settings, and configuration parameters can be downloaded again after reset. When the reset button is triggered, all LED lights will be on, and after the device reset is completed, the lights will be off (except PWR).
カタログの12ページ目を開く
CANopen to Maftj MG-CANEX S-COV 9-3$ VO led an* FYri? PowtflOtA STA run >A5<*o’CPCAf , ERR UoObwfrTC^CAVope"*
カタログの13ページ目を開く
4. Product usage 4.1 Operating principle of gateway Gateway protocol transformation belongs to address mapping mode, and the data of all devices in CANopen network are mapped to Modbus TCP data store. The TPDO of the CANopen slave equipment is mapped to the Modbus discrete quantity input and input register areas, and the RPDO is mapped to the Modbus coil and hold register areas. The SDO read command of the CANopen station device is mapped to the Modbus input register area (3XXXX), and the SDO write command is http:// www.odotautomation.com
カタログの14ページ目を開く
mapped to the Modbus hold register area (4XXXX). When the gateway receives the data from the slave, the data is stored in the Modbus buffer. When the data in the Modbus buffer changes, the gateway will send the data from the slave RPDO/SDO write commands to the CANopen network. The gateway data exchange principle is shown in the following figure. Modbus write Modbus Output buffer 3K Byte Modbus read Modbus Input buffer PDO adopts the producer/consumer mode to transmit data, with no response except request, and fast response, which is suitable for situations with high requirements on...
カタログの15ページ目を開く
od-t Sichuan Odot Automation System Co., Ltd PDO can be configured to transfer data. 4.2 Data objects are mapped in the Modbus cache 4.3 Network function 4.3.1 Network scanning The largest number of 127 nodes on the CANopen network, the gateway itself occupies one node address. The basic condition of the slave equipment on the CANopen network can be preliminarily scanned through the network scanning function.
カタログの16ページ目を開く
od«t Sichuan Odot Automation System Co., Ltd Network scan function is realized by adding network scan module. The corresponding relation of the data address of the network scanning module is as follows: Note: Green: read only; Blue: Feedback Control process: 1. Output trigger bit 0->1 rising edge, start the scan. 2. The scanning state is set to 1, and the number of nodes and module information are all reset. 3. Wait for the scan to complete, and the status bit in the scan is cleared to zero. 4. The number of nodes stores all nodes scanned by the current network, and the node ID and node...
カタログの17ページ目を開く
OCM Sichuan Odot Automation System Co., Ltd the device and is sent to other devices with the highest priority by the relevant application device. Suitable for interrupt type error warning signals. An emergency message consists of 8 bytes in the following format: sender ^receiver(s)
カタログの18ページ目を開くODOT Automationのすべてのカタログと技術パンフレット
-
C3351
8 ページ
-
BOXIO 64
4 ページ
-
ODOT remote IO catalogue
20 ページ
-
PLC
59 ページ
-
New small ODOT brochure
16 ページ
-
CN-8034
2 ページ
-
CN-8033
2 ページ
-
CN-8032
2 ページ
-
CN-8012
2 ページ
-
CN-8011
2 ページ
-
CN-8031
2 ページ
-
Remote I/O C Series
376 ページ
-
Remote I/O module
36 ページ
-
CT-7221
17 ページ
-
CT5800
15 ページ
-
CT4234
20 ページ
-
CT3804
21 ページ
-
CT-3713
19 ページ
-
CT3238
19 ページ
-
CT-3158
19 ページ
-
CT2718
18 ページ
-
CT2228
18 ページ
-
CT623F
23 ページ
-
CT-222F
19 ページ
-
CT-121F
21 ページ
-
MG-IOT03 User Manual_V1
24 ページ
-
ODOT-IOT02
44 ページ
-
ODOT-S7PPIV2.0
31 ページ
-
ODOT-PNM02
31 ページ
-
ODOT-S4E2
56 ページ
-
ODOT-IOT01
79 ページ