Ownership rights information Without the permission of the copyright owner, all or part of this document shall not be republished as a paper or electronic document. Disclaimer This document is only intended to assist the reader in using the products, and the company shall not be responsible for any loss or error caused by the use of the information in this document. The product and text described in this document are under constant development and refinement. Odot Automation System Co., Ltd. has the right to modify this document without notifying users. Software download Please log on the...
カタログの3ページ目を開く
od*t Odot Automation System Co., Ltd http:// www.odotautomation.com
カタログの4ページ目を開く
1 Product Overview Remote IO system consists of network adapter module and extended IO module. The network adapter module controls fieldbus communication and it realizes communication link with host station controller or host computer software. The extended IO module controls the connection with the input and output sensors in the field. At first the Input IO module collects the field signals and sends it to the network adapter through the internal bus. Secondly the controller reads and processing data from the adapter through the field bus, and it writes the output data into the network...
カタログの5ページ目を開く
od*t Odot Automation System Co., Ltd High speed backplane bus, the refresh cycle of 32 modules is 1ms. • The channels carry with Complete ODOT status indicator lights. self-design. Multiple input/output modules: DI/DO, AI/AO, special modules, extended power modules. Terminal Module 1.2 Module Layout The ODOT-C series is a remote I/O module. The adapter module lies on the far left, and on the right are extended I/O modules. http:// www.odotautomation.com
カタログの6ページ目を開く
1.3 LED Indicators The user can easily check the power state of adapter and I/O module, I/O module operating state, and the number of I/O channels though LED state. And the detailed indicator state should refer to the related adapter or IO modules. 1.4 Ground Protection There is one metal resilient sheet on the back of the module, which is used for effective grounding with the guide rail. The metal resilient sheet and the adapter PE (protective earthing) are connected internally.
カタログの7ページ目を開く
Use push-in method to connect single-wire or crimp terminal wires without any other tools. Users can save wiring time and ensure a safe operation regardless of wiring experience. The module equips with a wiring fixed end for cable harness, which is used to fix the cable when the IO module is wired with multiple cables. 1.6 Installation and Removal DIN-Rail Lock could be safely and reliably installed on 35 mm DIN-Rail. There is a manual closure buckle on the upper side of all modules for locking, and a manual buckle is on the left side of the adapter for locking the guide rail. http://...
カタログの8ページ目を開く
When the module is removed, it needs to manually unlock the guide rail on the upper side of the module. For the adapter module, you also need to unlock the left rail buckle counterclockwise.
カタログの9ページ目を開く
od*t Odot Automation System Co., Ltd Adapter size: 115*51.5*75mm I/O module size: 115*14*75mm 2 Extended IO module CT-2718: 8 channel relay output 2A/30VDC/60W 1 Module features ♦ 8-channel relay normally on output ♦ 8 LED channel indicators ♦ Low on resistance (<100mQ) ♦ 250VAC/220VDC the max. switch voltage is 250VAC/220VDC http:// www.odotautomation.com
カタログの10ページ目を開く
od*t Odot Automation System Co., Ltd http:// www.odotautomation.com
カタログの11ページ目を開く
© Module Type © State indicator © N/A © Wiring Terminal and identification © Internal Bus © Field Power © Buckle © Grounding Resilient Sheet @ Fixed Wiring Harness
カタログの12ページ目を開く
© Power LED indicator (red) © Module State LED indicator (red/green) © Output channel LED indicator (green) http:// www.odotautomation.com
カタログの13ページ目を開く
od*t Odot Automation System Co., Ltd http:// www.odotautomation.com
カタログの14ページ目を開く
od*t Odot Automation System Co., Ltd 4 Wiring http:// www.odotautomation.com
カタログの15ページ目を開く
Data description: Fault Action for Output Ch#(0-7): Fault output mode. When IO module detects that internal bus communication is failed and enters offline mode, the output data will be processed in this mode. (Default: 0) 0: Hold the last output state. 1: Output fault value Fault Value for Output Ch#(0-7): When the fault output mode is 1, this bit would set the fault output value, and when the internal bus of IO module is offline,
カタログの16ページ目を開く
od*t Odot Automation System Co., Ltd this setting value will be output.(Default: 0) 0: Output low level. 1: Output high level. http:// www.odotautomation.com
カタログの17ページ目を開く
______________________________________________________________ Odot Automation System Co., Ltd. Add: No.6 Hongsheng Road, Hi-Tech District, Mianyang, Sichuan, China. Tel: +86-0816-2538289 Zip Code: 621000 Email:sales@odotautomation.com Web: www.odotautomation.com http:// www.odotautomation.com
カタログの18ページ目を開くODOT Automationのすべてのカタログと技術パンフレット
-
C3351
8 ページ
-
BOXIO 64
4 ページ
-
ODOT remote IO catalogue
20 ページ
-
PLC
59 ページ
-
New small ODOT brochure
16 ページ
-
CN-8034
2 ページ
-
CN-8033
2 ページ
-
CN-8032
2 ページ
-
CN-8012
2 ページ
-
CN-8011
2 ページ
-
CN-8031
2 ページ
-
Remote I/O C Series
376 ページ
-
Remote I/O module
36 ページ
-
CT-7221
17 ページ
-
CT5800
15 ページ
-
CT4234
20 ページ
-
CT3804
21 ページ
-
CT-3713
19 ページ
-
CT3238
19 ページ
-
CT-3158
19 ページ
-
CT2228
18 ページ
-
CT623F
23 ページ
-
CT-222F
19 ページ
-
CT-121F
21 ページ
-
MG-IOT03 User Manual_V1
24 ページ
-
ODOT-IOT02
44 ページ
-
ODOT-S7PPIV2.0
31 ページ
-
ODOT-PNM02
31 ページ
-
ODOT-S4E2
56 ページ
-
ODOT-IOT01
79 ページ