カタログの抜粋

od-t Sichuan Odot Automation System Co., Ltd http: // www.odotautomation.com
カタログの1ページ目を開く
od-t Sichuan Odot Automation System Co., Ltd Prroduct Name: AI0B0X 10 Module Product Series: MimBOX Product Model AIOBOX-MT124F Power Supply: 9-36 VDC Operating Temperature -40-65 C Humidity: 5-95SRH(non-condensuig) LED Sratus PWR Power status DF device Fault RUN Modbus RUN ERR Communication Error IRN 10 RUN NC Not Used Sichuan Odot Automation system Co. Lli http://www odot cn Tel/QQ 400-1024-485 Copyright©2010 All rights reserved by Odot Automation http: // www.odotautomation.com
カタログの2ページ目を開く
od-t Sichuan Odot Automation System Co., Ltd Ownership information Without the consent of the copyright owner, part or whole of this document are not allowed to be republished in paper or electronic document. Disclaimer This document shall only be used to assist readers for the using of our products and the company shall not be responsible for any loss or error caused by the information in this document. The text and product described in this document is constantly developing and improving. Sichuan Odot Automation System Co., Ltd. has the right to modify this document without notifying...
カタログの3ページ目を開く
http:// www.odotautomation.com
カタログの4ページ目を開く
Od-t Sichuan Odot Automation System Co., Ltd 1 Product Overview 1.1 Product Introduction MiniBox series IO module: AIO-MT124F is an Ethernet based integrated IO module, with 16 input channels. This product supports the use of RS485 interface (Modbus-RTU) and Ethernet interface (Modbus-TCP) for communication, and supports the simultaneous access of 5 Modbus TCP clients. It is simple and convenient to use with stable transmission, full metal shell and strong anti-interference ability. The internal PCB adopts anti-corrosion technique including anti-corrosion, anti-oxidation and anti-salt mist....
カタログの5ページ目を開く
Firing Current http: // www.odotautomation.com
カタログの6ページ目を開く
ocf •t Sichuan Odot Automation System Co., Ltd Power wiring and RS485 Channel Gateway Indicator Wiring Terminal Product Name: AI080X10 Module Product Series: MimBOX Product Model: AIOBOX-MT124F Power Supply 9*36 VDC Operatng Temperature -aWIS'-C Hjnldity S*95WtH (norvconderang) jnal Indicator LED Status PWR Power status OF Device Fault RUN Modbus RUN ERR Communication Erw IRN IORUN NC No! Used Sdiuan Odol Automation System Co Ltd nap //wwwodder TeVGQ 400-102<-*85 Buckle 2.2 Indicator Description Symbol http: // www.odotautomation.com
カタログの7ページ目を開く
od-t Sichuan Odot Automation System Co., Ltd 2.3 System Power and Communication Interface A. System Power and Communication Ports Definition It supports standard Modbus-TCP and Modbus-RTU/ASCII protocol access. The Ethernet supports cascade function of dual Ethernet port switch, and the serial port supports RS485 bus connection mode. http: // www.odotautomation.com
カタログの8ページ目を開く
od-t Sichuan Odot Automation System Co., Ltd B. Terminal wiring diagram and definition Digital input module AIOBOX-MT124F has 16 digital input channels, and the module is simple for wiring and easy for operation. The specific wiring diagram is as follows. 1 DIO 2 Dll 3 DI2 4 DI3 5 DI4 6 DI5 7 DI6 8 DI7 9 COA 10 NC 11 DI8 12 DI9 13 DI10 14 Dill 15 DM2 16 DM3 17 DI14 18 DI15 19 COB 20 NC http: // www.odotautomation.com
カタログの9ページ目を開く
od-t Sichuan Odot Automation System Co., Ltd http: // www.odotautomation.com
カタログの10ページ目を開く
od-t Sichuan Odot Automation System Co., Ltd Dada description: MAC Address [0-5]: Device MAC address (read only) IP Address[0-3]: Device IP address (Default: 192.168.1.100) Net Mask[0-3]: Device subnet mask (Default: 255.255.255.0) Net Gateway[0-3]: Device subnet gateway (Default: 192.168.1.1) Modbus Port: Modbus Port no. (Default: 502) Effective range: 0-65535 Watchdog Enable: Modbus Watchdog enable (Default: 1) 0: Watchdog disabled 1 : Watchdog enabled Watchdog Time(s): Watchdog time (Default: 10) Effective range: 1-65535 Slave ID: Modbus slave station ID no. (Default: 1) Effective range:...
カタログの11ページ目を開く
od-t Sichuan Odot Automation System Co., Ltd 0: No parity 1: Odd 2: Even Stop Bits: stop bit (Default: 1) 1: 1 stop bit 2: 2 stop bit Serial Mode: serial mode (Default: 0) 0: RTU mode 1: ASCII mode Char Pitch: inter-frame space (Default: 2) 0: 1.5t 1: 3.5t 2: 5t 3: 10t 4: 20t 5: 50t 6: 100t 7: 200t Respond Delay: Slave station replying delay time (Default: 0) Effective range: 0-65535
カタログの12ページ目を開く
od-t Sichuan Odot Automation System Co., Ltd Data description: Input Filtering Time(ms): channel input filtering time, unit ms (Default: 10) Counter Value Data Format: The byte transfer sequence of channel count value (Default: 0) 0: A-B-C-D 1: B-A-D-C 2: C-D-A-B 3: D-C-B-A Input Holding Time(ms): input holding time, unit ms (Default: disable) Storage Enable: storage enabled (Default: disable) Count Mode Ch#(0-15): input channel count mode (Default: 0) 0: Rising edge count 1 : Falling edge count 2: Double edge count Count Direction Ch#(0-15): input channel count direction (Default: 0) 0:...
カタログの13ページ目を開く
Od*t Sichuan Odot Automation System Co., Ltd Prroduct Name: AI0B0X10 Module Product Series: MiniBOX Product Model: AIOBOX-MT124F Power Supply: 9-36 VDC Operating Temperature: -40-85“ C Humidity: 5'95%RH(non-condensing) LED Sratus PWR Power status OF device Fault RUN Modbus RUN ERR Communication Error IRN 10 RUN NC Not Used Sichuan Odot Automation system Co-Ltd pttp:Wwww.odoUn Tel/QQ 400-1024-485
カタログの14ページ目を開く
od-t Sichuan Odot Automation System Co., Ltd 3 Configuration Software Usage 1. Double-clicking on my computer, open the network and sharing center under the control panel, and set the COMPUTER IP and module IP in the same network segment. If the default IP of module is 192.168.1.100, then the IP of computer should be 192.168.1. X (1<X<254,X^100) 2 .After installing AIO-Box config software, opening the configuration software, clicking File ^ Project ^ New Project in the menu bar, or right clicking Project ^ New Project in the project directory bar, and entering the project name manually....
カタログの15ページ目を開く
3. In the project directory bar, right-clicking the Project Name → Upload IO module, and selecting scan module in the pop-up dialog box, selecting local network card, and clicking Search Device to scan AIO-MT124F module. http:// www.odotautomation.com
カタログの16ページ目を開くODOT Automationのすべてのカタログと技術パンフレット
-
C3351
8 ページ
-
BOXIO 64
4 ページ
-
ODOT remote IO catalogue
20 ページ
-
PLC
59 ページ
-
New small ODOT brochure
16 ページ
-
CN-8034
2 ページ
-
CN-8033
2 ページ
-
CN-8032
2 ページ
-
CN-8012
2 ページ
-
CN-8011
2 ページ
-
CN-8031
2 ページ
-
Remote I/O C Series
376 ページ
-
Remote I/O module
36 ページ
-
CT-7221
17 ページ
-
CT5800
15 ページ
-
CT4234
20 ページ
-
CT3804
21 ページ
-
CT-3713
19 ページ
-
CT3238
19 ページ
-
CT-3158
19 ページ
-
CT2718
18 ページ
-
CT2228
18 ページ
-
CT623F
23 ページ
-
CT-222F
19 ページ
-
CT-121F
21 ページ
-
MG-IOT03 User Manual_V1
24 ページ
-
ODOT-IOT02
44 ページ
-
ODOT-S7PPIV2.0
31 ページ
-
ODOT-PNM02
31 ページ
-
ODOT-S4E2
56 ページ
-
ODOT-IOT01
79 ページ