MultiCONT MULTICHANNEL PROCESS CONTROLLER
カタログの1ページ目を開く
MAIN FEATURES ■ As a Universal Process Controller provides for a flexible solution for commissioning a process control system consisting of any HART®-based intelligent (level, temperature or pressure) transmitters ■ Galvanically isolated 4 - 20 mA outputs for transmitters ■ Depending on the type of the transmitters 1 to 15 (standard) or 1 to 4 (Ex ia) channels ■ Highly informative 128 x 64 pixel large LCD / OLED display Intrinsically safe version Simple 6-button programming Trend logging into internal memory or SD memory card USB connector for downloading data from internal FLASH memory...
カタログの2ページ目を開く
DIMENSIONS Without lockable cover With lockable, transparent cover A Pg9 / M16 B Pg11 / M20 Arrangement of mounting holes WIRING4-relay version MAINS Only for UNICONT modules. **Only for non-Ex versions. After loosening and removing screws fastening the cover the cables can be connected. The same cable should not be used for AC and DC as well as for SELV and mains voltage. For wiring of the transmitters shielded, twisted cable pair (STP) should be used with the l ength depending on the number of connected units and the electrical properties of cable. RS485 interface: A: TRD+
カタログの3ページ目を開く
TRANSMITTERS OPERATING WITH MultiCONT ■ EchoTREK / EasyTREK - 2- or 4-wire ultrasonic level transmitters ■ MicroTREK - 2 -wire guided microwave level transmitters (max. 8 pcs. standard or max. 2 pcs. Ex ia version unit can be connected into one loop) ■ NIVOTRACK - 2 -wire magnetostrictive level transmitters ■ NIVOPRESS - 2-wire hydrostatic level transmitters ■ AnaCONT - 2-wire liquid analytical transmitters ■ THERMOCONT - 2-wire temperature transmitters ■ NIVOCAP - 2-wire capacitive level transmitters ■ THERMOPOINT - 2-wire multipoint temp. transmitters ■ PiloTREK - Non-contact microwave...
カタログの4ページ目を開く
COMMUNICATION BET WEEN MultiCONT AND TR ANSMIT TERS Point-To-Point connection With using a master (MultiCONT) and one slave (transmitter) in a system, a point-to-point connection is established. Multipoint connection (Multidrop). Multiple slaves connected in parallel Using this type of connection, the current outputs of the transmitters are automatically set to 4 mA (multidrop mode, with address differing from zero). PROGR A MMING OF MultiCONT During programming the following operations can be performed: ■■ utomatic detection of devices (transmitters) connected to A the MultiCONT. ■■...
カタログの5ページ目を開く
SYS T E M S E T- U P There is a Master-Slave relation between MultiCONT and the connected transmitters. MultiCONT queries the transmitters for their measured values and programs the transmitters remotely. In HART® multidrop mode when there are several transmitters connected to MultiCONT the transmitters have to be set to different polling addresses that differ from zero. This setting should be done one by one prior to the final wiring. In systems involving several MultiCONTs chained to one RS485 line all units have to have different polling addresses too. Wiring of 4-wire transmitters...
カタログの6ページ目を開くNIVELCO Process Control Co.のすべてのカタログと技術パンフレット
-
NIVELCO Magazine 2019/1
36 ページ
-
NIVELCO Magazine 2018/2
40 ページ
-
NIVELCO Magazine 2018/1
36 ページ
-
NIVELCO Magazine 2017/1
36 ページ
-
NIVELCO Magazine 2016/2
36 ページ
カタログアーカイブ
-
NIVELCO Magazine 2016/1
36 ページ
-
NIVELCO Magazine 2015/2
36 ページ
-
NIVELCO Magazine 2015/1
36 ページ
-
NIVELCO Magazine 2014/2
36 ページ
-
NIVELCO Magazine 2014/1
36 ページ
-
NIVELCO Magazine 2013/2
36 ページ
-
NIVELCO Magazine 2013/1
36 ページ
-
NIVELCO Magazine 2012/2
36 ページ
-
NIVELCO Magazine 2012/1
36 ページ
-
NIVELCO Magazine 2011/2
36 ページ
-
NIVELCO Magazine 2011/1
36 ページ
-
NIVELCO Magazine 2010/2
36 ページ