■■ Level and volume measurement ■■ Level measurement of conductive and non-conductive materials ■■ Level measurement of liquids ■■ For high pressure and high temperature mediums Max. 20 m (65.5 ft) measurement range Vertical mounting Rod or cable probe versions -30…+200°C (-22...+392 °F) medium temperature Max. 40 bar g (580 psi g) medium pressure 32-point linearization table Indirect assignment of 0% and 100% 4-20 mA + HART output Ex version IP67 protection G ENERAL D E S CR IP T IO N NIVOCAP 2-wire capacitive level transmitters provide an ideal solution for level measurement of conductive...
カタログの2ページ目を開く
Protection type Ex marking Intrinsically safe data Ex approved power supply and limit data Temperature classification ATEX X II 1G EEx ia IIB T6 Ci < 15 nF; Li < 200 juH; Ui < 30 V; Ii < 140 mA; Pi < 1 W Uo < 30 V; Io < 140 mA; Po < 1 W Temperature class: T6; Tambient : 70 °C (158 °F); Tmedium : 80 °C (176 °F)
カタログの3ページ目を開く
DIMENSIONS PROBE SELECTION Consequences of the capacitive operation principle: Relative dielectric constant of the medium should be taken into consideration. Measurement will be accurate only in case of suitable probe and reference probe selection.
カタログの4ページ目を開く
DISPLAY Basic functions can be configured by the programming buttons. With the help of the SAP-202 plug-in display a simplified programming can be accomplished which covers full parameter programming. Loop current measuring connector U- U+ 1 2 Display module connector 4-20 mA current output and power supply (HART) I- I+ 2 3 NI V O C A P TRA NS MI TTE RS I N H A RT MUL TI D RO P L O O P The MultiCONT processes and displays measurement data supplied by NIVELCO’s HART equipped transmitters connected to a Multidrop loop. Up to 15 transmitters (also mixed models) can be connected and remote...
カタログの5ページ目を開く
ORDER CODES (not all combinations available) NIVOCAP capacitive level transmitters NIVOCAP C (i) Type Code Transmitter Transmitter+display High temperature transmitter (2) High temperature transmitter+display (2) The order code of an Ex version should end in „Ex" (2) Not available in Ex version (3) Special process connections are available on request, e.g.: TRICLAMP, sanitary Code Probe length Code Nivelco reserves the right to change technical data without notice! ACCESSORIESNIVOCAP reference probes for capacitive rod probes NIVOCAP C -1 Code Probe length Code Process connection Code Probe...
カタログの6ページ目を開くNIVELCO Process Control Co.のすべてのカタログと技術パンフレット
-
NIVELCO Magazine 2019/1
36 ページ
-
NIVELCO Magazine 2018/2
40 ページ
-
NIVELCO Magazine 2018/1
36 ページ
-
NIVELCO Magazine 2017/1
36 ページ
-
NIVELCO Magazine 2016/2
36 ページ
カタログアーカイブ
-
NIVELCO Magazine 2016/1
36 ページ
-
NIVELCO Magazine 2015/2
36 ページ
-
NIVELCO Magazine 2015/1
36 ページ
-
NIVELCO Magazine 2014/2
36 ページ
-
NIVELCO Magazine 2014/1
36 ページ
-
NIVELCO Magazine 2013/2
36 ページ
-
NIVELCO Magazine 2013/1
36 ページ
-
NIVELCO Magazine 2012/2
36 ページ
-
NIVELCO Magazine 2012/1
36 ページ
-
NIVELCO Magazine 2011/2
36 ページ
-
NIVELCO Magazine 2011/1
36 ページ
-
NIVELCO Magazine 2010/2
36 ページ