グループ: 株式会社日本ピスコ

カタログの抜粋

Multi-stage nozzle High Vacuum Ejector at Low Air Pressure Supply Vacuum Generator Ensuring high vacuum pressure & high vacuum flow by low 50psi air supply High vacuum pressure & flow Supply Air Vacuum level Suction flow ● Three vacuum ports are available in one unit. Pneumatic symbol P
カタログの1ページ目を開く
Vacuum Generator Series Vacuum Generator VVV ■ Characteristic Long life cycle and easy maintenance. Vacuum ports direction can be changed. Instruction how to change the direction of vacuum ports is mentioned following page. ● Straight or elbow silencer is available depending upon the installing space. Straight exhaust Silencer ● Digital pressure gauge is available as an option
カタログの2ページ目を開く
Vacuum Generator Series Vacuum Generator VVV Suction transport ▶Best suitable for a large & heavy workpiece in industries such as packaging or automobile, or suitable for an air-permeable workpiece. Vacuum packing ▶Make a vacuum state in the bag, and then packing the products, including food. Defoaming/ deaeration ▶Removing air bubbles and air contained in adhesives, cosmetics (cream), distilled water, e
カタログの3ページ目を開く
■ Model Designation (Example) VVV VVV E Multi-stage nozzle Vacuum generator Nozzle dia. ① . Vacuum characteristic Code Type Vacuum characteristic Digital pressure gauge Exhaust port style Air supply port size Vacuum port size E High-vacuum at low air pressure supply type E type : High-vacuum at low air pressure supply type Suction flow Air consumption Vacuum level inHg(kPa) -26.8 inHg (-90) -27.8 inHg (-94) -27.8 inHg (-94) ③ . Vacuum port size Code 12 16 1/2 ø12 ø16 (5/8" O.D.) 1/2" O.D. (ø12.7) Size Port type Push-in straight fitting and plug Remarks PC1/2-04 (3 pc.) & PP1/2 (2 pc.) incl....
カタログの4ページ目を開く
■ Constructions Vacuum port (V) x 3 Air supply port (P) ⬅ Exhaust port (EX) Final Vacuum VVVE27 Vacuum characteristics Final Vacuum Final Vacuum-kPa NBR Aluminum Electroless nickel-plated SPCC Nickel-plated iron PBT PVF PBT Aluminum VVVE25 Vacuum characteristics Final Vacuum Flow characteristics Nozzle cover Bracket Fastening bolt Silencer unit Element Elbow adaptor block Nozzle 3 Part O-ring Final Vacuum-kPa Electroless nickel-plated brass Aluminum − NBR Aluminum Aluminum − Electroless nickel-plated brass Aluminum Vacuum level Final Vacuum-kPa Part Nozzle 1 Body Digital Pressure Gauge (Opt
カタログの5ページ目を開く
Detailed Safety Instructions Before using PISCO products, be sure to read “Safety Instructions” and “Safety Instruction Manual”, Instructions for Mechanical Vacuum Switch”. Warning 1. Maintenance of vacuum generator VVV shall be carried out by a person who has sufficient knowledge of vacuum equipment and understands structure. 1. Use of vacuum filter is recommended to prevent possible entering of foreign objects from vacuum port. 2. When selecting an exhaust piping or a use without silencer with dust existing in air or pipe, dust may enter from the exhaust port by back-flow at operation...
カタログの6ページ目を開く
Vacuum Generator Series Vacuum Generator VVV Dimentions of push-in fitting on vacuum port (V) Dimentions of push-in fitting on air supply port (P) Model code as Tube O.D. optional attachment C1 ※Weight of the plug for vacuum port push-in fitting Plug (PP1/2) for PC1/2-04 : 2.9g Model code as Tube O.D. optional attachment C2 5 3/8 1/2 08 10 12 Install push-in fittings on vacuum ports and supply port with a wrench. The following chart is the tightening torque. Port Supply Vacuum Rc thread is same as BSPT (female thread) 2. Connection and disconnection of Tubings ①. Tubing connection Push in a...
カタログの7ページ目を開く
■ Follow the below procedures for cleaning the nozzle and the diffuser. Please carry out a maintenance with su ficient attention not to get injured. ① Loosen fastening bolts of exhaust side, then remove the bracket and the exhaust head. ② Remove the nozzles and the diffuser from ejector body. By removing the exhaust head, the nozzles and the diffuser are released. However, the 1st stage nozzle may remain in the ejector. Loosen fastening bolts and remove the bracket and the air supply head and a fitting as well if equipped, then push out the 1st stage nozzle from the air supply port. Be...
カタログの8ページ目を開く
Vacuum Generator Series Vacuum Generator VVV ■ Method to change the vacuum port direction ■Follow the below procedures for changing vacuum port direction. ① Loosen fastening bolts of both port sides, then rotate the body to change the direction of vacuum ports. ② When changing the direction, be sure to align the Double-D seams of the heads and brackets when rotating the ejector body. ③ Fix the heads and brackets by tightening the fastening bolt with the tightening torque of 2.4 to 2.66Nm. Exhaust head ( D-cut face) ●Air supply port side Exhaust port Fastening bolt Exhaust head ( D-cut face)
カタログの9ページ目を開く
Common Safety Instructions for Vacuum Series Before selecting or using PISCO products, read the following instructions. Read the detailed instructions for individual series. 1. There is always a risk work pieces falling off during the vacuum operation. Please be sure to take into consideration safety measures against the falling of them or possible damage(s) caused by falling components. 2. Avoid supplying more than 14.5psi (0.1MPa) pressure constantly in a vacuum circuit. Since vacuum generators are not explosive-proof, there is a risk of damaging the products. 3. Pay attention to the...
カタログの10ページ目を開く
8. The material of plastic filter cover for VQ and VFU series is PA. Avoid the adherence of chemicals below to the products, and do not use them under those chemical environments. ● Table Chemical Name Chemical Name Chromic acid(10% 70℃) Chromic acid(25% 70℃) Chlorosulfonic acid Chlorotoluene Chlorobenzene Chemical Name Aniline Ethylene chlorohydrin Epichlorohydrin Ethyl chloride(Chloroethane) Thionyl chloride Benzyl chloride Methyl chloride Hydrochloric acid(20% 80℃) Hydrochloric acid(37% 20℃) Nitrohydrochloric acid Ozone Sodium peroxide Caustic soda(30% 70℃) Potassium permanganate Formic...
カタログの11ページ目を開くNIHON PISCO CO.のすべてのカタログと技術パンフレット
-
CTB series
1 ページ
-
FUS8 series
3 ページ
-
31 & 32 Series
20 ページ
-
Vacuum Pad Soft Series
86 ページ
-
VP series
106 ページ
-
CHA series
8 ページ
-
Gripper Series
15 ページ
-
SVB Series
50 ページ
-
SVA series
13 ページ
-
SVR series
31 ページ
-
NSB series
8 ページ
-
BV series
8 ページ
-
HV series
5 ページ
-
Plarailchain SC
15 ページ
-
Plarailchain SPO
12 ページ
-
Plarailchain SP
14 ページ
-
HPO
12 ページ
-
HPU
12 ページ
-
PJN series
15 ページ
-
KJNC series
15 ページ
-
SSJS series
6 ページ
-
Stainless SUS316
13 ページ
-
UE series
12 ページ
-
FB series
1 ページ
-
CTA series
1 ページ
-
SFTN series
2 ページ
-
SET series
1 ページ
-
SFT series
14 ページ
-
ULF series
12 ページ
-
UCQ series
2 ページ
-
UQ series
12 ページ
-
NB series
12 ページ
-
NA series
12 ページ
-
UD series
12 ページ
-
UBS series
12 ページ
-
UBT series
12 ページ
-
UC series
1 ページ
-
UB series
12 ページ
-
AK/AS series
26 ページ
-
NK series
18 ページ
-
Brass Series
30 ページ
-
V-0 series
27 ページ
-
EG Series
27 ページ
-
PP Fitting series
12 ページ
-
PP Series
26 ページ
-
AP series
18 ページ
-
SL series
16 ページ
-
P-SUS series
33 ページ
-
NS series
24 ページ
-
SSP series
8 ページ
-
ATS series
6 ページ
-
Air Filter
20 ページ
-
Combination Unit Series
25 ページ
-
SFU series
9 ページ
-
JP series
15 ページ
-
ET series
11 ページ
-
EQ series
19 ページ
-
CVLU series
21 ページ
-
CV series
24 ページ
-
JN series
25 ページ
-
JSD series
10 ページ
-
JS Low-Flow series
17 ページ
-
JSC series
13 ページ
-
JS series
30 ページ
-
MA series
16 ページ
-
RH series
16 ページ
-
R series
16 ページ
-
PS series
16 ページ
-
L series
41 ページ
-
FUS20
7 ページ
-
GP series
13 ページ
-
VUS12 series
2 ページ
-
VUS21 series
14 ページ
-
VUS8-S series
22 ページ
-
JSD series
10 ページ
-
JK series
10 ページ
-
RVFUP series
6 ページ
-
VLF series
16 ページ
-
VFL series
8 ページ
-
VF series
22 ページ
-
ECV series
8 ページ
-
VPLFC, VPLFD series
17 ページ
-
VPKE series
4 ページ
-
RPV06 Series
8 ページ
-
VZ Series
34 ページ
-
VX Series
42 ページ
-
VQ Series
4 ページ
-
VN Series
40 ページ
-
VK series
53 ページ
-
VJ Series
34 ページ
-
VG series
21 ページ
-
VRL series
17 ページ
-
VLS series
4 ページ
-
VM | VC series
28 ページ
-
VY series
24 ページ
-
VB series
11 ページ
-
VH | VS series
28 ページ
-
VPHMP series
12 ページ
-
VYR series
5 ページ
-
HS series
13 ページ
-
HML series
14 ページ
-
VRG series
18 ページ
-
Dry Unit Series
33 ページ
-
Fiber Membrane Air Dryer
12 ページ
-
VLM series
12 ページ
-
VSPE series
5 ページ
-
VT series
21 ページ
-
PB series
13 ページ
-
JSG series
17 ページ
-
pararel
3 ページ
-
fitting
4 ページ
-
BJSU series
4 ページ
-
SC
15 ページ
-
SPO
12 ページ
-
SP
13 ページ
-
RPV pump
8 ページ
-
Pre-set
6 ページ
-
Flange
13 ページ
-
HML
14 ページ
-
VYR
5 ページ
-
EOAT VRG | VMG series
18 ページ
-
VPLFC
17 ページ
-
SVB
172 ページ
-
SVR
39 ページ
-
8mm Sensor
22 ページ
-
Vacuum Filter
28 ページ
-
Fall Prevention
18 ページ
-
Vacuum Pen
21 ページ
-
Push-Rod Release
4 ページ
-
cylinder
22 ページ
-
FDAbellows
6 ページ
-
Oval
80 ページ
-
sponge
50 ページ
-
mark-free
34 ページ
-
flat
42 ページ
-
Ultrathin
34 ページ
-
packaging bag
13 ページ
-
multi-bellow
46 ページ
-
bellows pad
74 ページ
-
Skid proof pad
42 ページ
-
soft bellow pad
60 ページ
-
soft pad
66 ページ
-
VRL
17 ページ
-
VH VS VC VUM VU VY VB
336 ページ
-
VZ
34 ページ
-
VX
42 ページ
-
VVV
11 ページ
-
VQ
42 ページ
-
VN
40 ページ
-
VLS
4 ページ
-
VLM
12 ページ
-
VK
53 ページ
-
VJ
34 ページ
-
VG
21 ページ
-
Vacuum Tube
12 ページ
-
Twin Coiling
12 ページ
-
Tube Cutter
12 ページ
-
Polyurethane Tube
12 ページ
-
Nylon Tube Series
12 ページ
-
Multi-core Planar Tube
12 ページ
-
Insert Ring
12 ページ
-
Fluororesin (PFA) Tube
14 ページ
-
UL series
12 ページ
-
Anti-spatter Tube
12 ページ
-
Tube Fitting PP Series
26 ページ
-
Tube Fitting Mini Series
41 ページ
-
K series
30 ページ
-
Stop Fitting Series
16 ページ
-
Rotary Joint Series
16 ページ
-
Minimal Fitting Series
20 ページ
-
Main Block Series
24 ページ
-
Light Coupling Series
24 ページ
-
High Rotary Joint Series
16 ページ
-
Connector Series
16 ページ
-
Color Cap
12 ページ
-
Vacuum EOAT Kit HML
14 ページ
-
Vacduum gripper
18 ページ
-
SSNC series
13 ページ
-
SJSC series
24 ページ
-
Speed Controller Series
32 ページ
-
KJSC series
17 ページ
-
Silencer Series
13 ページ
-
Pressure Gauge Series
13 ページ
-
Miniture quick-exhaust
17 ページ
-
Check Valve
4 ページ
-
Parallel Gripper
6 ページ
-
JSG
17 ページ
-
GENERAL
106 ページ
-
Mechanical Valve Series
19 ページ
-
Ball Valve Series
19 ページ
-
Hand Valve Series
15 ページ
-
Change Valve
11 ページ
-
SVA21 Series
21 ページ
-
P Series
71 ページ
-
SVA20 Series
43 ページ
-
RegulatorPL031821m
12 ページ
-
BJSU series
6 ページ
-
NP68-01e
17 ページ