カタログの抜粋

Technical Sales (866) 531-6285 orders@ni.com Requirements and Compatibility | Ordering Information | Detailed Specifications | Pinouts/Front Panel Connections For user manuals and dimensional drawings, visit the product page resources tab on ni.com. 8 counter/timers with 26 channel-to-channel isolated inputs and 8 channel-to-channel isolated outputs 400 kHz maximum frequency with 48 VDC voltage range on inputs and outputs Short-circuit protection on outputs with automatic recovery Superior features for automotive test, industrial monitoring, and control applications NI-DAQmx software for highest productivity and performance Reverse and overvoltage protection (±60 V max continuous), and transient overvoltage input protection (±400 V peak) Requirements and Compatibility OS Information Driver Information Software Compatibility Windows Vista Measurement Studio SignalExpress Comparison Tables Product Counter/Timers Size Compatibility 5 V logic thresholds Application and Technology Overview NI PCI-6624 and PXI-6624 devices are industrial isolated timing interfaces for PCI and PXI/Compact PCI bus systems. You can use the eight 32-bit channel-to-channel optically isolated counter/timers of an NI 6624 device to perform a wide variety of buffered measurements or other counter/timer tasks, including position or quadrature encoder measurement, edge counting, period measurement, pulse-width measurement, frequency measurement, semiperiod measurement, two-edge separation measurement, pulse-width-modulation (PWM) generation, pulse, and pulse-train generation. NI 6624 devices offer superior features and high value for automotive test, industrial monitoring, and manufacturing test applications such as factory automation, embedded machine control, and production line verification. They incorporate the latest hardware technologies and provide innovative features for applications requiring ease of use, high reliability, and performance. NI 6624 devices take advantage of NI-DAQmx software (Version 7.2 or later), which speeds up application development with many helpful features such as the NI DAQ Assistant, automatic code generation, and high-performance multithreaded streaming technology. Connect Sensors Directly with Channel-to-Channel Isolation Isolation is a form of built-in signal conditioning that provides several advantages including an extended voltage range for direct connection to industrial sensors and actuators. It also improves signal quality and protects computer circuitry. NI 6624 devices offer channel-to-channel isolation, where every channel is physically and electrically separated from the others, which breaks ground loops, improves common-mode voltage and noise rejection, and permits the two parts of the circuit to be at different voltage levels. Many industrial applications require isolation to protect the electronics from transient voltage spikes and provide greater common-mode noise rejection in electrically noisy environments containing machinery and inductive loads. Counter/Timers Based on NI-TIO ASIC NI 6624 devices are equipped with the NI-TIO ASIC, a National Instruments counter and digital I/O ASIC for advanced timing and counting applications. Each NI 6624 features two NI-TIO ASICs to provide a total of eight counter/timers. Each counter has a gate, auxiliary, and source input, which you can control with external or internal signals. Each
カタログの1ページ目を開く
counter also has one output that you can route externally or to other counters on the device. 20 MHz and 100 kHz timebases are available on each device for use with each counter/timer. You can use a hardware trigger to start multiple counters simultaneously. Figure 1. NI 6624 Hardware Block Diagram Buffered Measurements NI 6624 devices use the National Instruments MITE bus interface controller to implement bus-master DMA transfers. As a result, you can perform high-speed, continuous operations such as buffered position encoder measurement and buffered period measurement. You can perform up...
カタログの2ページ目を開く
• Use the NI DAQ Assistant to guide you to fast, accurate measurements with no programming • Use automatic code generation to create your application in LabVIEW, ANSI C, Visual Basic .NET, or C# • Take advantage of multithreaded streaming technology for 1000X performance improvements • Use automatic timing, triggering, and synchronization technology to make advanced applications easy • Visit ni.com for more than 3,000 free software downloads to jump-start your project • Use NI-DAQmx functions for jumper-free software configuration of all counter/timer and digital I/O features without...
カタログの3ページ目を開く
Repair While you may never need your hardware repaired, NI understands that unexpected events may lead to necessary repairs. NI offers repair services performed by highly trained technicians who quickly return your device with the guarantee that it will perform to factory specifications. For more information, visit ni.com/repair. Training and Certifications The NI training and certification program delivers the fastest, most certain route to increased proficiency and productivity using NI software and hardware. Training builds the skills to more efficiently develop robust, maintainable...
カタログの4ページ目を開く
Input channels to backplane (bus) Input channels to ground Input channel to channel Propagation Delays (for a 5 V Input Signal) Number of output channels Sinking (low-side switch) Output type Output power requirement Load voltage range Switching current Inrush current Maximum output frequency Minimum output pulse width Typical switching times (with a 5 V, 100 Ω load) Output low maximum voltage (with SH100-100-S2 cable) Output leakage current when OFF Protection Short circuit (on output pins) 0.6 A min, 1.1 A max (stays off after detecting a short circuit and retries to operate every 250 ms,...
カタログの5ページ目を開く
Star trigger 100-pin female, SCSI-II type Maximum Working Voltage Maximum working voltage refers to the signal voltage plus the common-mode voltage. Channel-to-earth Caution Do not use this module for connection to signals or for measurements within Categories II, III, or IV. Environment NI 6624 devices are intended for indoor use only. 2,000 meters (at 25 °C ambient temperature) Maximum altitude Pollution Degree Operating Environment Ambient temperature range 0 to 55 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) Relative humidity range 10 to 90%, noncondensing (Tested in...
カタログの6ページ目を開くNATIONAL INSTRUMENTS/ナショナルインスツルメンツのすべてのカタログと技術パンフレット
-
NI 9381
10 ページ
-
NI 9402
9 ページ
-
BNC-2121
3 ページ
-
Counter/Timer
10 ページ
-
NI PXIe-6612
12 ページ
-
ds-392
7 ページ
-
ETC_196
9 ページ
-
ds-293
13 ページ
-
ds-353
14 ページ
-
ds-361
5 ページ
-
NI WSN-3202
13 ページ
-
cat_ni31xx
5 ページ
-
PXI-4072 FlexDMM
5 ページ
-
GPIB-USB-HS
7 ページ
-
2005_6175_161_101
4 ページ
-
Digital I/O,
9 ページ
-
NI PCIe-6321
15 ページ
-
NI USB-6509
8 ページ
-
NI_PCI-6713.
5 ページ
-
NI_PCIe-6363
5 ページ
-
NI_GPIB-USB-HS
4 ページ
-
NI_EVS-1464
9 ページ
-
daqsc208-209_212-2
2 ページ
-
ds-153
18 ページ
-
ds-37
14 ページ
-
NI4065
6 ページ
-
4daqsc253
17 ページ
-
NI_1778_Smart_Camera
5 ページ
-
NI_PCI-5122
5 ページ
-
4daqsc253-265_194-196
17 ページ
-
NI-Datasheet-ds-293
13 ページ
-
NI_PXIe-8100_RT
3 ページ
-
NI_FPT-1015
3 ページ
-
NI_PXI-2501
5 ページ
-
2005_6174_161_101_d
5 ページ
-
cat_FET
3 ページ
-
cat_evs1464RT
9 ページ
-
4daqsc253-265
17 ページ
-
043918301101dlr
7 ページ
-
4daqsc208-209
2 ページ
-
usb-datasheet
14 ページ
-
NI_9478
4 ページ
-
NI_9239_Measurement_
4 ページ
-
_Measurement_System
4 ページ
-
Measurement_System
4 ページ
-
_Measurement_
4 ページ
-
NI_cDAQ-9171
3 ページ
-
NI_cDAQ-9174
5 ページ
-
NI_cDAQ-9178
5 ページ
-
NI_cDAQ-9181
4 ページ
-
NI_cDAQ-9188
5 ページ
-
Wireless_Chassis
1 ページ
-
NI_cDAQ-9139
4 ページ