Multifunction Input and Output Devices
1 / 24ページ

{{requestButtons}}

カタログの抜粋

Multifunction Input and Output Devices - 1

Multifunction Input and Output Devices PRODUCT FLYER CONTENTS Multifunction I/O Device PXI Multifunction I/O Module Platform-Based Approach to Test and Measurement Hardware Services

カタログの1ページ目を開く
Multifunction Input and Output Devices - 2

■ Software: Includes DAQExpress™ interactive measurement software as well as API support for LabVIEW and text-based languages, shipping examples, and detailed help files ■ Analog, Digital and Counter/Timer I/O in one device ■ USB or PCI/PCIe bus connectivity ■ Voltage measurements up to 10 MS/s per channel ■ Multiplexed or simultaneous analog architectures ■ Software-selectable input ranges and input channel isolation available ■ Up to four analog output channels and four counters Built for Accuracy and Reliability NI Multifunction I/O Devices provide a combination of analog I/O, digital...

カタログの2ページ目を開く
Multifunction Input and Output Devices - 3

Table 1. NI USB multifunction I/O devices provide a simple plug-in interface with many specification options. Page 3 | ni.com | Multifunction I/O

カタログの3ページ目を開く
Multifunction Input and Output Devices - 4

*ST=Screw Terminals | MT=Mass Termination | BNC=BNC Terminals **Has only dedicated digital input and/or digital output lines Table 2. NI PCI(e) multifunction I/O devices add high quality I/O to a desktop PC. ST Page 4 | ni.com | Multifunction I/O

カタログの4ページ目を開く
Multifunction Input and Output Devices - 5

Page 5 | ni.com | Multifunction I/O

カタログの5ページ目を開く
Multifunction Input and Output Devices - 6

Page 6 | ni.com | Multifunction I/O

カタログの6ページ目を開く
Multifunction Input and Output Devices - 7

*Simultaneous - sample rate is per output channel Page 7 | ni.com | Multifunction I/O

カタログの7ページ目を開く
Multifunction Input and Output Devices - 8

Mass termination for cabled connectivity *Screw terminal and BNC terminal variants also available Page 8 | ni.com | Multifunction I/O

カタログの8ページ目を開く
Multifunction Input and Output Devices - 9

Mass termination for cable connectivity Stream data through PCI Express Page 9 | ni.com | Multifunction I/O

カタログの9ページ目を開く
Multifunction Input and Output Devices - 10

High Resolution, High Accuracy Analog Measurements NI Multifunction I/O Devices have analog signal paths that have been meticulously designed, tested, and calibrated to ensure the highest possible accuracy is achieved across all input channels. Because of this thorough design-and-test philosophy, NI is able to provide thoroughly documented accuracy specifications to allow a complete understanding of device performance under a range of possible operating conditions. The specifications documentation for each device provides a section dedicated to understanding the calculation of AI absolute...

カタログの10ページ目を開く
Multifunction Input and Output Devices - 11

Independent Timing Engines for Analog and Digital I/O Advanced timing and triggering functionality on data acquisition devices has often relied on onboard counters and complex signal routing to achieve specialized hardware-timed performance. NI’s multifunction I/O technology offers completely independent sample clocks and triggers for each different group of I/O on a multifunction device. Retriggerable acquisitions, for example, involve waiting for a trigger condition to be met, taking a finite number of samples, and then immediately rearming the trigger for the next acquisition. Using...

カタログの11ページ目を開く
Multifunction Input and Output Devices - 12

NI-DAQmx Application Programming Interface (API) The NI-DAQmx driver includes a best-in-class API that works directly with a variety of development options including LabVIEW, DAQExpress, C, C#, Python, and others. The native integration provides exceptional performance and a seamless experience without the need for manual wrapping of functions. To ensure long-term interoperability of DAQ devices, the NI-DAQmx driver API is the same API used for all NI DAQ products - meaning re-development efforts can be minimized regardless of hardware changes or upgrades. Additionally, the driver provides...

カタログの12ページ目を開く
Multifunction Input and Output Devices - 13

■ Software: Includes API support for LabVIEW and text-based languages, complete with shipping examples and detailed help files. ■ Voltage measurements up to 10 MS/s per channel ■ Analog, Digital and Counter/Timer I/O in one device ■ Multiplexed or simultaneous analog architectures ■ Software-selectable input ranges and input channel isolation available ■ Up to four analog output channels and four counters/timers ■ PXI and PXI Express platform compatibility Page 13 | ni.com | Multifunction I/O

カタログの13ページ目を開く
Multifunction Input and Output Devices - 14

Built for Accuracy and Reliability NI PXI Multifunction I/O Modules provide a combination of analog I/O, digital I/O, and counter/timer functionality in a single device for PXI-based systems. PXI Multifunction I/O Modules offer a mix of I/O with varying channel counts, sample rates, output rates, and other features to meet many common measurement requirements. These devices are ideal for a wide variety of industry applications such as laboratory automation, research, and design verification. The included NI-DAQmx driver enables complete customization of measurement and automation...

カタログの14ページ目を開く
Multifunction Input and Output Devices - 15

Page 15 | ni.com | Multifunction I/O Flyer

カタログの15ページ目を開く
Multifunction Input and Output Devices - 16

Page 16 | ni.com | Multifunction I/O Flyer

カタログの16ページ目を開く
Multifunction Input and Output Devices - 17

*Simultaneous - sample rate is per output channel Mass termination connectivity -cabled to terminal block Page 17 | ni.com | Multifunction I/O Flyer

カタログの17ページ目を開く
Multifunction Input and Output Devices - 18

Key Features High Resolution, High Accuracy Analog Measurements NI PXI Multifunction I/O Modules have analog signal paths that have been meticulously designed, tested, and calibrated to ensure the highest possible accuracy is achieved across all input channels. Because of this thorough design-and-test philosophy, NI is able to provide thoroughly documented accuracy specifications to allow a complete understanding of device performance under a range of possible operating conditions. The specifications documentation for each Device provides a section dedicated to understanding the calculation...

カタログの18ページ目を開く
Multifunction Input and Output Devices - 19

group of I/O on a multifunction device. Retriggerable acquisitions, for example, involve waiting for a trigger condition to be met, taking a finite number of samples, and then immediately rearming the trigger for the next acquisition. Using driver software function calls to rearm the trigger risks missing the next trigger due to software latency; therefore, the best possible performance requires a hardware-timed approach. In the past, counters were the only way to implement hardware-timed retriggering, and so counters would be used to generate a retriggerable pulse train, which was then...

カタログの19ページ目を開く
Multifunction Input and Output Devices - 20

Synchronization and Integration PXI Multifunction I/O Modules use the inherent timing and synchronization capabilities of the PXI platform to synchronize measurements between multiple modules, which is ideal for high-channel-count applications. PXI builds on its CompactPCI architecture base by adding integrated timing and synchronization that is used to route synchronization clocks and triggers internally. A PXI chassis incorporates a dedicated 10 MHz system reference clock, PXI trigger bus, star trigger bus, and slot-toslot local bus, while a PXI Express chassis adds a 100 MHz differential...

カタログの20ページ目を開く

NATIONAL INSTRUMENTS/ナショナルインスツルメンツのすべてのカタログと技術パンフレット

  1. NI 9381

    10 ページ

  2. NI 9402

    9 ページ

  3. BNC-2121

    3 ページ

  4. Counter/Timer

    10 ページ

  5. NI PXIe-6612

    12 ページ

  6. ds-392

    7 ページ

  7. ETC_196

    9 ページ

  8. ds-293

    13 ページ

  9. ds-353

    14 ページ

  10. ds-361

    5 ページ

  11. NI WSN-3202

    13 ページ

  12. cat_ni31xx

    5 ページ

  13. PXI-4072 FlexDMM

    5 ページ

  14. GPIB-USB-HS

    7 ページ

  15. 2005_6175_161_101

    4 ページ

  16. Digital I/O,

    9 ページ

  17. NI PCIe-6321

    15 ページ

  18. NI USB-6509

    8 ページ

  19. NI_PCI-6713.

    5 ページ

  20. NI_PCIe-6363

    5 ページ

  21. NI_GPIB-USB-HS

    4 ページ

  22. NI_EVS-1464

    9 ページ

  23. daqsc208-209_212-2

    2 ページ

  24. ds-153

    18 ページ

  25. ds-37

    14 ページ

  26. NI4065

    6 ページ

  27. 4daqsc253

    17 ページ

  28. NI_PCI-5122

    5 ページ

  29. NI-Datasheet-ds-293

    13 ページ

  30. NI_PXIe-8100_RT

    3 ページ

  31. NI_FPT-1015

    3 ページ

  32. NI_PXI-2501

    5 ページ

  33. cat_FET

    3 ページ

  34. cat_evs1464RT

    9 ページ

  35. 4daqsc253-265

    17 ページ

  36. 043918301101dlr

    7 ページ

  37. 4daqsc208-209

    2 ページ

  38. usb-datasheet

    14 ページ

  39. NI_9478

    4 ページ

  40. Measurement_System

    4 ページ

  41. _Measurement_

    4 ページ

  42. NI_cDAQ-9171

    3 ページ

  43. NI_cDAQ-9174

    5 ページ

  44. NI_cDAQ-9178

    5 ページ

  45. NI_cDAQ-9181

    4 ページ

  46. NI_cDAQ-9188

    5 ページ

  47. Wireless_Chassis

    1 ページ

  48. NI_cDAQ-9139

    4 ページ

カタログアーカイブ