カタログの抜粋

Technical Sales (866) 531-6285 orders@ni.com Requirements and Compatibility | Ordering Information | Detailed Specifications | Pinouts/Front Panel Connections For user manuals and dimensional drawings, visit the product page resources tab on ni.com. Low-Cost Industrial Digital I/O – 5 V TTL/CMOS Overview NI 6509 industrial digital I/O interfaces are ideal for general-purpose data acquisition applications as well as industrial control and automated manufacturing test. With high-current drive, you can connect the digital I/O interface directly to a wide array of 5 V electronic devices, sensors, and actuators. These interfaces offer superior features and high value for industrial control and manufacturing test applications such as factory automation, embedded machine control, and production line verification. They are designed to incorporate the latest hardware technologies and provide innovative features for applications requiring ease of use, high reliability, and performance. NI 6509 interfaces take advantage of NI-DAQmx measurement services software to speed up application development with many helpful features including the DAQ Assistant, automatic code generation, and high-performance multithreaded streaming technology. Back to Top Requirements and Compatibility OS Information Driver Information Software Compatibility ANSI C/C++ LabVIEW LabWindows/CVI Measurement Studio SignalExpress Visual Basic Visual C# Visual Studio .NET Comparison Tables Product Input Lines Application and Technology Hardware High-Reliability Industrial Feature Set
カタログの1ページ目を開く
NI 6509 devices offer a set of high-reliability features designed to automate even the most demanding applications: Programmable power-up states provide safe operation when connected to pumps, valves, motors, and relays Digital I/O watchdogs detect computer or application errors and ensure safe recovery Change detection triggers your application and returns I/O data after a digital event with minimal processor usage Programmable input filters eliminate glitches/spikes and remove noise Glitch-Free Startup with Programmable Power-Up States With programmable power-up states, you can configure...
カタログの2ページ目を開く
Figure 3. NI PCIe-6509 Digital I/O Circuitry Detect and Recover with Digital I/O Watchdogs NI digital I/O watchdogs provide protection against a wide variety of fault conditions: Computer crash – total OS crash Application crash – software application ceases to respond Driver crash – device driver ceases to respond PCI bus failure – communications cease to respond With watchdogs, the digital outputs go to a safe state when a fault condition is detected and the watchdog timer expires for safe recovery. Watchdogs are important whenever the device is connected to actuators such as pumps,...
カタログの3ページ目を開く
Ordering Information For a complete list of accessories, visit the product page on ni.com. Part Number Recommended Accessories Part Number NI PCI-6509 NI PCI-6509 Requires: 1 Cables , 1 Connector Blocks ; Cables: Shielded - SH100-100-F Cable (2m) **Also Available: [Unshielded] Connector Blocks: Spring-Screw_Terminals - SCB-100 Cable: Shielded - SH100-100-F Cable (2m) **Also Available: [Unshielded] Connector Block: Spring-Screw_Terminals - SCB-100 NI PXIe-6548- 1 Mb/ch NI PXI-6509 Requires: 1 Cable , 1 Connector Block ; Software Recommendations LabVIEW Professional Development System for...
カタログの4ページ目を開く
NI measurement hardware is calibrated to ensure measurement accuracy and verify that the device meets its published specifications. To ensure the ongoing accuracy of your measurement hardware, NI offers basic or detailed recalibration service that provides ongoing ISO 9001 audit compliance and confidence in your measurements. To learn more about NI calibration services or to locate a qualified service center near you, contact your local sales office or visit ni.com/calibration. Technical Support Get answers to your technical questions using the following National Instruments resources....
カタログの5ページ目を開く
Input high-Z (default), output 1 or 0 Input pulled up or down (software-selectable), output 1 or 0 Data transfers 100-pin female 0.050 series SCSI I/O connector Pull resistor (NI PCIe-6509 only) Pull-up resistor Pull-down resistor Input voltage protection (NI PCIe-6509 only) Digital Logic Levels (NI PCI/PXI-6509) Input Signals The maximum input logic high and output logic high voltages assume a Vcc supply voltage of 5.0 V. Given a Vcc supply voltage of 5.0 V, the absolute maximum voltage rating for each I/O line is –0.5 V to 5.5 V with respect to GND. Level Input logic high voltage (VIH) 2...
カタログの6ページ目を開く
Output Signals Level High-level output current (IOH) Low-level output current (IOL) Output voltage (Vout) Output high voltage (VOH), at –24 mA 3.4 V — Output low voltage (VOL), at 24 mA The total current sinking/sourcing from one port cannot exceed 100 mA. Without the disk drive power connector installed, the +5 V supply and the DIO lines share the same power source. In this case, use the following equation to determine the current available at the +5 V terminal. In the equation, I DIO is the total current sourced on all DIO lines. I+5V = 1.2 A − IDIO With the disk drive power connector...
カタログの7ページ目を開く
Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: ■ EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity ■ EN 55011 (CISPR 11): Group 1, Class A emissions ■ AS/NZS CISPR 11: Group 1, Class A emissions ■ FCC 47 CFR Part 15B: Class A emissions Note For EMC declarations and certifications, refer to the Online Product Certification section. ^J, Note For EMC...
カタログの8ページ目を開く
Pinouts/Front Panel Connections
カタログの9ページ目を開く
©2010 National Instruments. All rights reserved. CompactRIO, CVI, FieldPoint, LabVIEW, Measurement Studio, MITE, National Instruments, National Instruments Alliance Partner, Nl, ni.com, NI-DAQ, and SignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent...
カタログの10ページ目を開くNATIONAL INSTRUMENTS/ナショナルインスツルメンツのすべてのカタログと技術パンフレット
-
NI 9381
10 ページ
-
NI 9402
9 ページ
-
BNC-2121
3 ページ
-
Counter/Timer
10 ページ
-
NI PXIe-6612
12 ページ
-
ds-392
7 ページ
-
ETC_196
9 ページ
-
ds-293
13 ページ
-
ds-353
14 ページ
-
ds-361
5 ページ
-
NI WSN-3202
13 ページ
-
cat_ni31xx
5 ページ
-
PXI-4072 FlexDMM
5 ページ
-
GPIB-USB-HS
7 ページ
-
2005_6175_161_101
4 ページ
-
Digital I/O,
9 ページ
-
NI PCIe-6321
15 ページ
-
NI USB-6509
8 ページ
-
NI_PCI-6713.
5 ページ
-
NI_PCIe-6363
5 ページ
-
NI_GPIB-USB-HS
4 ページ
-
NI_EVS-1464
9 ページ
-
daqsc208-209_212-2
2 ページ
-
ds-153
18 ページ
-
ds-37
14 ページ
-
NI4065
6 ページ
-
4daqsc253
17 ページ
-
NI_1778_Smart_Camera
5 ページ
-
NI_PCI-5122
5 ページ
-
4daqsc253-265_194-196
17 ページ
-
NI-Datasheet-ds-293
13 ページ
-
NI_PXIe-8100_RT
3 ページ
-
NI_FPT-1015
3 ページ
-
NI_PXI-2501
5 ページ
-
2005_6174_161_101_d
5 ページ
-
cat_FET
3 ページ
-
cat_evs1464RT
9 ページ
-
4daqsc253-265
17 ページ
-
043918301101dlr
7 ページ
-
4daqsc208-209
2 ページ
-
usb-datasheet
14 ページ
-
NI_9478
4 ページ
-
NI_9239_Measurement_
4 ページ
-
_Measurement_System
4 ページ
-
Measurement_System
4 ページ
-
_Measurement_
4 ページ
-
NI_cDAQ-9171
3 ページ
-
NI_cDAQ-9174
5 ページ
-
NI_cDAQ-9178
5 ページ
-
NI_cDAQ-9181
4 ページ
-
NI_cDAQ-9188
5 ページ
-
Wireless_Chassis
1 ページ
-
NI_cDAQ-9139
4 ページ