Process Flow Meter Calibration System
1 / 24ページ

{{requestButtons}}

カタログの抜粋

Process Flow Meter Calibration System - 2

Calibration is a Comparison between the reading of a Device (Unit under Test) and that of a Standard. The process which establishes this relationship is a set of interrelated measurements and set of operations which provide the Comparison. After flow meters are manufactured / procured, they need to be calibrated before being sent out into the field. Most flow meter manufacturers have their own flow meter calibration facilities for performing this initial calibration. Calibration of flow meters enables us to optimize their utility, with the result that the Uncertainty between the actual...

カタログの2ページ目を開く
Process Flow Meter Calibration System - 3

PROCESS FLOW METER CALIBRATION SYSTEM FLOCAL SERIES Flow meter measures the rate of flow of fluid which passes through it. Flow meters are used in wide variety of applications where accurate flow measurements are critical in various sectors like Energy, Power, Refineries, Utilities, Water Management, Aerospace, Pharmaceutical Industry etc. In critical applications like these, it's important to Calibrate the Flow Meters to enable make reliable measurements. Regular Calibrations assure you that the Flow Meter's Measurements are as accurate as their specifications. Even the most rugged Flow...

カタログの3ページ目を開く
Process Flow Meter Calibration System - 4

3D VIEW OF FLOCAL SYSTEM COMPARISON METHOD

カタログの4ページ目を開く
Process Flow Meter Calibration System - 5

Specifications / Features 'PROCESS' FLOW METER CALIBRATION SYSTEM Nofe: Gravimetric Calibration can be performed up to 6,000 Liters volume on the basis of 1 minute (60 Seconds) campaign (i.e. Flow rate 6000 LPM). For volume higher than 6,000 Liters (for e.g. flow rates higher than 6,000 liters I minute) Gravimetric Calibration Campaign time will be varied according to the set flow rate.

カタログの5ページ目を開く
Process Flow Meter Calibration System - 6

3D VIEW OF FLOCAL SYSTEM AUTOMATIC SYSTEM

カタログの6ページ目を開く
Process Flow Meter Calibration System - 7

Specifications / Features 'PROCESS' FLOW METER CALIBRATION SYSTEM Nofe: Gravimetric Calibration can be performed up to 12,000 Liters volume on the basis of 1 minute (60 Seconds) campaign (i.e. Flow rate 12000 LPM). For volume higher than 12,000 Liters (for e.g. flow rates higher than 12,000 liters I minute) Gravimetric Calibration Campaign time will be varied according to the

カタログの7ページ目を開く
Process Flow Meter Calibration System - 8

WATER METER CALIBRATION TEST BENCH SYSTEM WATCAL SERIES It is every one's responsibility to save water, which is a precious commodity. After all, out of 100% of the Worlds' Water resource, only 3% of the water is usable, this imposes moral responsibility to precisely use this natural & scarce resource. Nag man Designed & introduced 'WATCAL' - Water Meter Calibration Systems, for Calibrating the Accuracy of: Domestic Water Meters, typically in sizes Industrial / Bulk Water Meters, typically in sizes In accordance with the Standard ISO4064/3, BIS 779 Domestic Water Meters and Bulk Water...

カタログの8ページ目を開く
Process Flow Meter Calibration System - 10

3D VIEW OF WATCAL SYSTEM COMPARISON METHOD

カタログの10ページ目を開く
Process Flow Meter Calibration System - 11

Specifications / Features WATER METER CALIBRATION TEST BENCH SYSTEM

カタログの11ページ目を開く
Process Flow Meter Calibration System - 13

Specifications / Features WATER METER CALIBRATION TEST BENCH SYSTEM

カタログの13ページ目を開く
Process Flow Meter Calibration System - 14

3D VIEW OF WATCAL SYSTEM VOLUMETRIC METHOD

カタログの14ページ目を開く
Process Flow Meter Calibration System - 15

Specifications / Features WATER METER CALIBRATION TEST BENCH SYSTEM

カタログの15ページ目を開く
Process Flow Meter Calibration System - 16

3D VIEW OF WATCAL SYSTEM

カタログの16ページ目を開く
Process Flow Meter Calibration System - 17

Specifications / Features WATER METER CALIBRATION TEST BENCH SYSTEM

カタログの17ページ目を開く
Process Flow Meter Calibration System - 18

WATER METER CALIBRATION TEST BENCH SYSTEM WATCAL 50300 SERIES (Contd.) Gravimetric Calibration can be performed up to 12,000 Liters volume on the basis of 1 minute (60 Seconds) campaign (i.e. Flow rate 12000 LPM). For volume higher than 12,000 Liters (for e.g. How rates higher than 12,000 liters/minute) Gravimetric Calibration Campaign time will be varied according to the set flow ** Volumetric Method: Measuring Capacity By using One Diverter System & 2 Nos. of Large Volumetric Tanks (2000 - 3000L) (Cascaded Double Decker). Once Maximum Level (5000 L) reaches in Tank 1, the PROXIMITY SWITCH...

カタログの18ページ目を開く
Process Flow Meter Calibration System - 19

FLUID FLOW CALIBRATION LABORATORY Nagman's Centre for Calibration is the first Calibration Laboratory in India to be Accredited as per ISO/IEC 17025:2005 being managed by dedicated, highly qualified, trained & Competent Experts in the field of Calibration to take care of all types of Customer's specific requirements & provide solution. Centre for Calibration is a unit of Nagman Instruments & Electronics Private Ltd., Chennai. This Calibration Lab is Accredited by NABL India to provide Calibration Services as per ISO/IEC 17025:2005 Standards. The Team consists of Qualified & NABL Empaneled...

カタログの19ページ目を開く
Process Flow Meter Calibration System - 20

DOMESTIC GAS METER CALIBRATION SYSTEM BELL PROVER METHOD GASCAL SERIES Calibration method for any particular flow meter is governed by the meter type, the ranges of flow and flow conditions, pressure, temperature and the accuracy of calibration required. In general all the methods have analogies with the liquid methods. The main difference between the calibration of a gas flow meter and a liquid device is the compressibility of the fluid. When calibrating a gas flow meter the temperature, pressure and hence volume of gas measured by the standard will be different from that at the device...

カタログの20ページ目を開く
Process Flow Meter Calibration System - 21

GASCAL SYSTEM BELL PROVER

カタログの21ページ目を開く
Process Flow Meter Calibration System - 22

DOMESTIC GAS METER CALIBRATION SYSTEM BELL PROVER METHOD The 'Calibration Standard' of the Test system is "Bell Prover", which is considered a Primary (Calibration) Standard to Test & Calibrate Domestic Gas Meters. The device is ideal for OEMs, Calibration Laboratories & Calibration Service Providers. The Test System with Bell Prover of Capacity (100L) will effectively cover Vey Low (Q min - 0.016 mVhr.) to Maximum (Q max - 4 mVhr.) Flow Rates. Accuracy: 0.5% F.S. It can test Q-max, 0.2Q-max, and Q- min separately as per different gas meters. Bell Prover has built-in Pump to deliver the Air...

カタログの22ページ目を開く
Process Flow Meter Calibration System - 23

DOMESTIC GAS METER CALIBRATION SYSTEM BELL PROVER METHOD The 'Calibration Standard' of the Test system is "Bell Prover", which is considered a Primary (Calibration) Standard to Test & Calibrate Domestic Gas Meters. The device is ideal for OEMs, Calibration Laboratories & Calibration Service Providers. The Test System with Bell Prover of Capacity (200L) will effectively cover Vey Low (Q min - 0.016 m7hr.) to Maximum (Q max - 4 mVhr.) Flow Rates. Accuracy: 0.5% F.S. It can test Q-max, 0.2Q-max, and Q- min separately as per different gas meters. Bell Prover has built-in Pump to deliver the Air...

カタログの23ページ目を開く

Nagman Instruments & Electronics (P) Ltd.のすべてのカタログと技術パンフレット

  1. MTC 650

    2 ページ

  2. ETC 600/ETC 600-2

    1 ページ

  3. MTC 1200

    2 ページ

  4. Level Transmitters

    4 ページ

  5. Flow Meters

    8 ページ

  6. Test Bench

    24 ページ

  7. Product Flier

    4 ページ

  8. GCL & GCH Series

    2 ページ

  9. HHP Series

    2 ページ

  10. PHP2 Series

    2 ページ

  11. Model BBS-VH

    2 ページ

  12. Model BBSD

    2 ページ

  13. BBSL, BBSM & BBSH

    2 ページ

  14. Model 1500HN

    2 ページ

  15. Model 1200HN

    2 ページ

  16. Model MTC650

    2 ページ

  17. Model MP650

    2 ページ

  18. Model 650H

    2 ページ

  19. Model 350H

    2 ページ

  20. Model MP40R

    2 ページ