RTX Rotary Index Tables
1 / 20ページ

{{requestButtons}}

カタログの抜粋

RTX Rotary Index Tables - 2

* Dimensions depend on the used drive

カタログの2ページ目を開く
RTX Rotary Index Tables - 3

Fitting position Load on output flange Load on central column Torque on output flange [Nm] 10 Axial runout on the output flange 0 [mm] * Increased indexing accuracy accessible through selected components From division 16, the division error due to multi-point locks on the drive cam is larger by a factor of 1.5“ Combined loads and possible process forces must be confirmed by Motion Index Drives. Standard drive Motor size

カタログの3ページ目を開く
RTX Rotary Index Tables - 4

Load table RTX350 n = Number of stops / 360° revolution of output flange t = Step time in [s] JMax = Mass moment of inertia (base plate + fixtures and parts) in [Kgm2] Without motor and lifetime JL = Mass moment of inertia by life time (base plate + fixtures and parts) in [Kgm2] J = Mass moment of inertia with motor (base plate + fixtures and parts) in [Kgm2] From n=16 The output flange steps 2 times per cam revolution From n=36 The output flange steps 3 times per cam revolution

カタログの4ページ目を開く
RTX Rotary Index Tables - 5

* Dimensions depend on the used drive

カタログの5ページ目を開く
RTX Rotary Index Tables - 6

Fitting position Load on output flange Radial force F,a [N] 17.5 Axial force F3a [kN] 20 Torque on output flange [Nm] 322 Load on central column Precision Axial runout on the output flange 0 [mm] * Increased indexing accuracy accessible through selected components From division 16, the division error due to multi-point locks on the drive cam is larger by a factor of 1.5“ Axial force FaM [kN] 18 Torque on output flange [Nm] 77 Combined loads and possible process forces must be confirmed by Motion Index Drives. Standard drive Output flange 0 Motor size

カタログの6ページ目を開く
RTX Rotary Index Tables - 7

Load table RTX450 n = Number of stops / 360° revolution of output flange t = Step time in [s] JMax = Mass moment of inertia (base plate + fixtures and parts) in [Kgm2] Without motor and lifetime JL = Mass moment of inertia by life time (base plate + fixtures and parts) in [Kgm2] J = Mass moment of inertia with motor (base plate + fixtures and parts) in [Kgm2] From n=16 The output flange steps 2 times per cam revolution From n=36 The output flange steps 3 times per cam revolution

カタログの7ページ目を開く
RTX Rotary Index Tables - 8

Position of the hole pattern in the output flange Stop number Further stop numbers you can find in the RTF/RTX550 dimension sheet at our website. * Dimensions depend on the used drive

カタログの8ページ目を開く
RTX Rotary Index Tables - 9

Fitting position Load on output flange Radial force FrA [kN] 23 Axial force FaA [N] 18.4 Torque on output Precision Axial runout on the output flange 0 [mm] * Increased indexing accuracy accessible through selected components From division 16, the division error due to multi-point locks on the drive cam is larger by a factor of 1.5“ Axial force FaM [kN] 18 Torque on output flange [Nm] 77 Combined loads and possible process forces must be confirmed by Motion Index Drives. Standard drive Output flange 0 Motor size

カタログの9ページ目を開く
RTX Rotary Index Tables - 10

Load table RTX550 n = Number of stops / 360° revolution of output flange t = Step time in [s] JMax = Mass moment of inertia (base plate + fixtures and parts) in [Kgm2] Without motor and lifetime JL = Mass moment of inertia by life time (base plate + fixtures and parts) in [Kgm2] J = Mass moment of inertia with motor (base plate + fixtures and parts) in [Kgm2] From n=16 The output flange steps 2 times per cam revolution From n=36 The output flange steps 3 times per cam revolution

カタログの10ページ目を開く
RTX Rotary Index Tables - 12

Fitting position Load on output flange Radial force FrA [kN] 20 Axial force FaA [kN] 22.5 Torque on Precision Axial runout on the output flange 0 [mm] * Increased indexing accuracy accessible through selected components From division 16, the division error due to multi-point locks on the drive cam is larger by a factor of 1.5“ Axial force FaM [kN] 14 Torque on output flange [Nm] 170 Combined loads and possible process forces must be confirmed by Motion Index Drives. Standard drive Output flange 0 Motor size

カタログの12ページ目を開く
RTX Rotary Index Tables - 13

Load table n = Number of stops / 360° revolution of output flange t = Step time in [s] JMax = Mass moment of inertia (base plate + fixtures and parts) in [Kgm2] Without motor and lifetime JL = Mass moment of inertia by life time (base plate + fixtures and parts) in [Kgm2] J = Mass moment of inertia with motor (base plate + fixtures and parts) in [Kgm2] From n=16 The output flange steps 2 times per cam revolution From n=36 The output flange steps 3 times per cam revolution

カタログの13ページ目を開く
RTX Rotary Index Tables - 14

* Dimensions depend on the used drive

カタログの14ページ目を開く
RTX Rotary Index Tables - 15

Fitting position Load on output flange Load on central column Axial runout on the output flange 0 [mm] Radial force FrM [kN] 3.8 Axial force FaM [kN] 15 Torque on output * Increased indexing accuracy accessible through selected components From division 16, the division error due to multi-point locks on the drive cam is larger by a factor of 1.5" Standard drive Motor size

カタログの15ページ目を開く
RTX Rotary Index Tables - 16

Load table RTX750 n = Number of stops / 360° revolution of output flange t = Step time in [s] JMax = Mass moment of inertia (base plate + fixtures and parts) in [Kgm2] Without motor and lifetime JL = Mass moment of inertia by life time (base plate + fixtures and parts) in [Kgm2] J = Mass moment of inertia with motor (base plate + fixtures and parts) in [Kgm2] From n=16 The output flange steps 2 times per cam revolution From n=36 The output flange steps 3 times per cam revolution

カタログの16ページ目を開く
RTX Rotary Index Tables - 17

* Dimensions depend on the used drive

カタログの17ページ目を開く
RTX Rotary Index Tables - 18

Fitting position Load on output flange Load on central column Axial runout on the output flange 0 [mm] * Increased indexing accuracy accessible through selected components From division 16, the division error due to multi-point locks on the drive cam is larger by a factor of 1.5“ Axial force FaM [kN] 25 Torque on output flange [Nm] 450 Combined loads and possible process forces must be confirmed by Motion Index Drives. Standard drive Output flange 0 Motor size

カタログの18ページ目を開く
RTX Rotary Index Tables - 19

Load table RTX900 n = Number of stops / 360° revolution of output flange t = Step time in [s] JMax = Mass moment of inertia (base plate + fixtures and parts) in [Kgm2] Without motor and lifetime JL = Mass moment of inertia by life time (base plate + fixtures and parts) in [Kgm2] J = Mass moment of inertia with motor (base plate + fixtures and parts) in [Kgm2] From n=16 The output flange steps 2 times per cam revolution From n=36 The output flange steps 3 times per cam revolution

カタログの19ページ目を開く