Interbus Interface
1 / 22ページ

{{requestButtons}}

カタログの抜粋

Interbus Interface - 1

microSYST Systemelectronic GmbH, Zur Centralwerkstätte 10, D-92637 Weiden, Germany Tel. +49 961 39166-0, Fax +49 961 391 66-10, info@microsyst.de, www.microsyst.de migan FI Large Format Numeric LED Display with InterBus Interface User’s Manual

カタログの1ページ目を開く
Interbus Interface - 2

migan FI Large Format Numeric LED Display with InterBus Interface Page 2 microSYST Systemelectronic GmbH, Zur Centralwerkstätte 10, D-92637 Weiden, Germany Tel. +49 961 39166-0, Fax +49 961 39166-10, info@microsyst.de, www.microsyst.de Index 1 GENERAL 3 1.1 Display Functions 3 2 SYSTEM OVERVIEW 4 3 TECHNICAL DATA 5 3.1 Device Configuration 6 3.2 Device or System Start-Up 7 3.3 Control via the InterBus Interface 8 3.3.1 User Data – IB Output 8 3.3.2 User Data – IB Input 8 3.4 Standard Transmission Frame (IB-Output) 9 3.4.1 Example 9 3.5 Alternative Transmission Frame (IB-Output) 10 3.5.1...

カタログの2ページ目を開く
Interbus Interface - 3

migan FI Large Format Numeric LED Display with InterBus Interface Page 3 microSYST Systemelectronic GmbH, Zur Centralwerkstätte 10, D-92637 Weiden, Germany Tel. +49 961 39166-0, Fax +49 961 39166-10, info@microsyst.de, www.microsyst.de 1 General The large display numeric LED can be used universally for displaying production data, or as an information board. The modular design allows for cost-effective models of various sizes, and with different character heights and numbers of digits. Thus integration into existing equipment or systems is easy and simple. 1.1 Display Functions · Data...

カタログの3ページ目を開く
Interbus Interface - 4

migan FI Large Format Numeric LED Display with InterBus Interface Page 4 microSYST Systemelectronic GmbH, Zur Centralwerkstätte 10, D-92637 Weiden, Germany Tel. +49 961 39166-0, Fax +49 961 39166-10, info@microsyst.de, www.microsyst.de 2 System Overview Schematic diagram of the display unit at the interface. InterBus Large Format Numeric LED Display RS 485 InterBus-Interface Large Format Numeric LED Display with InterBus-Interface I/O-Modul I/O-Modul IB-Master

カタログの4ページ目を開く
Interbus Interface - 5

migan FI Large Format Numeric LED Display with InterBus Interface Page 5 microSYST Systemelectronic GmbH, Zur Centralwerkstätte 10, D-92637 Weiden, Germany Tel. +49 961 39166-0, Fax +49 961 39166-10, info@microsyst.de, www.microsyst.de 3 Technical Data Overall Specifications Display type: 7 segment LED Character height: 60 mm, 100 mm, 150 mm, 200 mm, 250 mm Display colour: red, green, yellow Displayable Characters: 0…9, -, H, E, L, P, Blank View: single or double sided Interface: InterBus Operating voltage: 230 V / 50 Hz, 110 V / 60 Hz or 24 VDC Power Consumption: 60 mm approx. 1.5 W per...

カタログの5ページ目を開く
Interbus Interface - 6

migan FI Large Format Numeric LED Display with InterBus Interface Page 6 microSYST Systemelectronic GmbH, Zur Centralwerkstätte 10, D-92637 Weiden, Germany Tel. +49 961 39166-0, Fax +49 961 39166-10, info@microsyst.de, www.microsyst.de 3.1 Device Configuration Character Height: 60 mm 100 mm 150 mm 200 mm 250 mm Number of Lines: ________ Number of digits per Line: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Display colour: red green yellow Dimensional display: Line 1: __________ Line 5: __________ Line 2: __________ Line 6: __________ Line 3: __________ Line 7: __________ Line 4: __________ Line 8:...

カタログの6ページ目を開く
Interbus Interface - 7

migan FI Large Format Numeric LED Display with InterBus Interface Page 7 microSYST Systemelectronic GmbH, Zur Centralwerkstätte 10, D-92637 Weiden, Germany Tel. +49 961 39166-0, Fax +49 961 39166-10, info@microsyst.de, www.microsyst.de 3.2 Device or System Start-Up The large format numeric LED display performs internal memory and function tests while powering up. The following data appear at the large format display: · Baud rate · Parity · Data bits · Stop bits · - 1 2 3 4 5 ... · Address. The displayed values are of no significance for the InterBus user. This setting influences control via...

カタログの7ページ目を開く
Interbus Interface - 8

migan FI Large Format Numeric LED Display with InterBus Interface Page 8 microSYST Systemelectronic GmbH, Zur Centralwerkstätte 10, D-92637 Weiden, Germany Tel. +49 961 39166-0, Fax +49 961 39166-10, info@microsyst.de, www.microsyst.de 3.3 Control via the InterBus Interface Data received by the InterBus („out“ words) are stored to intermediate memory, processed and transmitted to the large format display. After the frame has been transmitted, the frame data are mirrored via the InterBus as a response („in“ words). 4 IB In Words SUPI 3 Interbus Interface 4 IB Out Words Intermediate Memory 4...

カタログの8ページ目を開く
Interbus Interface - 9

migan FI Large Format Numeric LED Display with InterBus Interface Page 9 microSYST Systemelectronic GmbH, Zur Centralwerkstätte 10, D-92637 Weiden, Germany Tel. +49 961 39166-0, Fax +49 961 39166-10, info@microsyst.de, www.microsyst.de 3.4 Standard Transmission Frame (IB-Output) For activation of this frame type see chapter 4.1. Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Char Digit 1/2 Char Digit 3/4 Char Digit 5/6 Char Digit 7/8 Char Digit 9/10 Char Digit 11/12 Option 1 Option 2 HIGH-Nibble / LOW-Nibble (see coding char) see coding option 1 see coding option 2 Coding Char Char...

カタログの9ページ目を開く
Interbus Interface - 10

migan FI Large Format Numeric LED Display with InterBus Interface Page 10 microSYST Systemelectronic GmbH, Zur Centralwerkstätte 10, D-92637 Weiden, Germany Tel. +49 961 39166-0, Fax +49 961 39166-10, info@microsyst.de, www.microsyst.de 3.5 Alternative Transmission Frame (IB-Output) For activation of this frame type see chapter 4.1. Data byte 1 Data byte 2 Data byte 3 Data byte 4 Data byte 5 Data byte 6 Data byte 7 … n Data byte n+1 STX ADRH ADRL PB1 PB2 PB3 1…15 chars (depending on number of digits) ETX 3C H 30 H 31 H see coding of point bytes ASCII code of the char, which shall be...

カタログの10ページ目を開く
Interbus Interface - 11

migan FI Large Format Numeric LED Display with InterBus Interface Page 11 microSYST Systemelectronic GmbH, Zur Centralwerkstätte 10, D-92637 Weiden, Germany Tel. +49 961 39166-0, Fax +49 961 39166-10, info@microsyst.de, www.microsyst.de 3.5.1 Interbus Frame for controlling the Display Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Toggle byte Data byte 1 Data byte 2 Data byte 3 Data byte 4 Data byte 5 Data byte 6 Data byte 7 Toggle byte The interface at the large format display is driven with the first byte of output data (toggle byte TB). The toggle byte is saved to intermediate...

カタログの11ページ目を開く

MicroSYST Systemelectronicのすべてのカタログと技術パンフレット

  1. Display systems

    32 ページ

カタログアーカイブ

  1. catalogue

    92 ページ

  2. miline FTL10

    1 ページ

  3. migra

    2 ページ

  4. Stopwatch Function

    11 ページ

  5. CANopen Interface

    29 ページ

  6. Product overview

    22 ページ

  7. Product catalog

    101 ページ

  8. info brochure

    2 ページ

  9. mison

    2 ページ

  10. migra-migan

    2 ページ

  11. mipick

    2 ページ