グループ: METZ CONNECT Holding
カタログの抜粋

BMT-AOP2 – Analog BACnet MS/TP output module for building automation
カタログの1ページ目を開く
METZ CONNECT – BACnet MS/TP - Analog I/O output module BMT-AOP2 The BMT-(F)-AOP2 BACnet MS/TP module with 2 analog voltage outputs has been developed for local switching tasks in automation for BACnet environments. It is suitable as a variable encoder for, e.g. electric ventilation and mixing flaps, valve actuation, frequency inverters or electronic ballasts (EB) for lighting systems. The outputs about standard objects can be issued via a BACnet-Client. Via 2 potentiometers on the front, each output can be changed from automatic to manual mode independently of each other. There are two...
カタログの2ページ目を開く
Details Analog output module with screw terminal connection BMT-AOP2 Operating modes for OUT 1 and OUT 2. Enter the “present value” 1 for 10 V mode or 2 for 12 V mode via the BACnet object “multistate value”. See software manual at www.metz-connect.com Rotary switches X1 and X10 for setting the device address or bitrate (factory setting: 9600 Bit/s) OUT 1 Analog output 0-10 V DC / 0-12 V DC (150 mA) e.g. EVG for LED lighting Connection via mini terminal or jumper/bridging plug Connection for jumper/bridging plug RS485 BACnet MS/TP RS485 BACnet MS/TP OUT 2 Analog output 0-10 V DC / 0-12 V DC...
カタログの3ページ目を開く
METZ CONNECT – BACnet MS/TP – Analog I/O output module Analog output module with spring terminal connection (Push-In) NG-F-4, BMT-F-RTR and BMT-F-AOP2 Jumper/bridging plug for transmitting the operating voltage 24 V DC/700 mA Support terminals e.g. RS485 BACnet MS/TP OUT 24 V DC/700 mA Power supply unit NG4 Jumper/bridging plug for transmitting the 24 V DC operating voltage and RS485 BACnet MS/ TP Bus BACnet Router BMT-RTR RJ45 connection for connecting to BACnet/IP network Analog output module BMT-AOP2 (For details, see image on left) RS485 BACnet MS/TP Connection of BACnet MS/TP end...
カタログの4ページ目を開く
System image Visualization Programming Parametrization Monitoring BACnet-Router, BMT-F-RTR Control BACnet MS/TP BACnet MS/TP Ventilation flap BCS = Building Control System
カタログの5ページ目を開く
METZ CONNECT GmbH Im Tal 2 78176 Blumberg Germany Phone +49 7702 533- 0 Fax +49 77 2 533-189 0 info@metz-connect.com www.metz-connect.com METZ CONNECT Zhongshan Ltd. 200 Tornillo Way Tinton Falls, NJ 07712 USA Phone + 1-732-389-1300 Fax + 1-732-389-9066 Ping Chang Road Ping Pu Industrial Park Sanxiang Town Zhongshan City, 528 463 Guangdong Province China Phone + 6 760 86365 055 8 Fax + 6 760 86365 050 8 28, Rue Schweighaeuser 67000 Strasbourg France Phone + 33 38 86 170 73 Fax + 33 38 86 194 73 METZ CONNECT AUSTRIA GmbH c/o German chamber of commerce in Austria Schwarzenbergplatz 5, Top...
カタログの6ページ目を開く