Consensus with ISO 13849-1
1 / 6ページ

カタログの抜粋

Consensus with ISO 13849-1 - 1

MAYSER* Consensus with ISO 13849-1 F0 en Mayser GmbH & Co. KG Orlinger StraBe 1-3 89073 Ulm GERMANY Phone: +49 731 2061-0 Fax: +49 731 2061-222 E-mail: info.ulm@mayser.com Internet: www.mayser.com

カタログの1ページ目を開く
Consensus with ISO 13849-1 - 2

Safety according to ISO 13849-1:2015 Performance Level Category MTTFd level MTTFD DCavg level DC avg B10D [* 106] Reaction time 11 assumed parameters : dop = 365 d/a, hop = 24 h/d, tcycle = 600 s (nop = 52560/a) 2) Suitable for installation of Category 3 systems up to PL d. 3) MTTFd level and value are dependent on the particular application (see page 4) 4) dependent on profile 2/6 Consensus with ISO 13849-1

カタログの2ページ目を開く
Consensus with ISO 13849-1 - 3

Miniature safety edges EKS assumed parameters : dop = 365 d/a, hop = 24 h/d, tcycle = 600 s (nop = 52560/a) Suitable for installation of Category 3 systems up to PL d. 3) MTTFD level and value are dependent on the particular application (see page 4). 4)

カタログの3ページ目を開く
Consensus with ISO 13849-1 - 4

Determining the PLr For each selected safety function it is first necessary to determine the required performance level (PLr) and to compare it with the performance level (PL) achieved by the Mayser sensor. The PLr of the safety function must correspond at least to the PL. Example 1: Safety mat in front of processing centre with 30-second cycle in 3-shift operation, 250 days per year. nop= 120 actuations/h x 24 h/day x 250 days = 720,000 actuations per year MTTFd = B10D/ (0.1 x nop) = 6,000,000 / (0.1 x 720,000) = 83.3 years => MTTFd high Example 2: NC safety edge on sliding gate with 2...

カタログの4ページ目を開く
Consensus with ISO 13849-1 - 5

The same example with exclusion of error according to ISO 13849-2 Table D.8: Non-closing of contacts in the case of pressure-sensitive equipment according to ISO 13856. In this case the MTTFD value of the sensor is no longer taken into account for the overall system. Example 4: As in example 3; Safety mat SM connected to SG-EFS 1X4 ZK2/1. MTTFd SG = 313 years -1- -1- MTTFd 313 years MTTFd = 313 years => MTTFD high In this case, the maximum performance level of the overall system can reach PL d. DCavg table Designation DCavg

カタログの5ページ目を開く
Consensus with ISO 13849-1 - 6

Determining the PL If the categories, DCavgand MTTFDare known, the performance level (PL) can be determined based on the table. The table shows a simplified procedure for assessment and is used in the first step for estimating the PL. => DC low avg => MTTFd high => PL d Example 5: SG-EFS 104/2W Category 3 DCavg = 60 % MTTFd = 257 years Result:

カタログの6ページ目を開く

Mayserのすべてのカタログと技術パンフレット

  1. Public transport

    9 ページ

  2. Industry Brochure

    16 ページ

  3. Product catalog

    268 ページ

  4. Safety shoe

    4 ページ

  5. Automotive Brochure

    11 ページ

カタログアーカイブ

  1. Aviation brochure

    9 ページ

  2. DIY Sensor Profiles

    13 ページ

  3. Control Units

    3 ページ

  4. Safety Mat SM11

    13 ページ

  5. Safety Mats SM

    20 ページ

  6. Safety Bumper

    10 ページ

  7. Safety Edges

    34 ページ

  8. Safety Bumpers

    10 ページ