890 Sries High Performance compact solenoid multi-valve \ 2/2 NC PNEUMATIC DIVISION MATRIX ^^^mmechatronics www.matrix. to.it sales@matrix. to.it

カタログの1ページ目を開く
MATRIX Pneumatic Division - 890 Series High Performance compact solenoid multi-valve - 2/2 NC x 9 - 2

MATRIX 890 Sries High Performance Solenoid Multi-Valve 2/2 - NC Developed to satisfy the increasing needs of size rduction and performances optimization for important and technologically evolved industrial sectors such as textile, sorting and packaging, the new 890 S驩ries offers high level technical characteristics and performances. Matrix's technology applied in the 890 Sries, in fact, grants extremely fast response times combined with minimum sizes, ideals for ail the applications where the dimension and the actuation speed are critical factors. Multi-shutters design modularity offers a...

カタログの2ページ目を開く
MATRIX Pneumatic Division - 890 Series High Performance compact solenoid multi-valve - 2/2 NC x 9 - 3

890 2/2 NC CONTROL GENERAL CHARACTERISTICS FLUID Non-lubricated dry air, neutral gases (-10 + 50°C) FILTRATION RATING Min 40 micron TEMPERATURE -10 + 50°C (Standard version) RESPONSE TIME IN OPENING 24 < 5 ms XX/KK< 1 ms RESPONSE TIME IN CLOSING 24 < 2 ms XX/KK< 1 ms MAXIMUM FREQUENCY 200 Hz 500 Hz WEIGHT 160g PRODUCT LIFE EXPECTANCY > 500 M/s cycles IP RATING IP62 IDENTIFICATION CODE SINGLE OUTLET FLOW RATE (at 6 bar) 100 N//min 140N//min (control tension !XX|[KK_) 180 N//min (control tension XX||KK CONTROL TENSION No. ELECTRICAL CONTROLS 24 24 VDC ±10% 2.9 Win XX Speed-up in current (48...

カタログの3ページ目を開く
MATRIX Pneumatic Division - 890 Series High Performance compact solenoid multi-valve - 2/2 NC x 9 - 4

890 2/2 NC 41,5 35,6 ACCESSORIES Rթfrence Quantity Description 1 1 Push-in fitting for D.12 tube Note: Inch size available CHARACTERISTICS OF THE ELECTRICAL CONTROL - MODELS KK CHARACTERISTICS OF THE ELECTRICAL CONTROL - MODELS XX -P100% H (VI) - P 100 % Pressure run Pressure run Tension run Current run N.B. KK MODELS ARE CONTROLLED IN TENSION N.B. XX MODELS ARE CONTROLLED IN CURRENT V1 = 24 VDC t 1 = 2 V 2 = 5 VDC I 1 = 0.5 A t 1 =1.5 ms 2 = 0.2 A V1 = 24 VDC t 1 = 2 ms V 2 = 5 VDC 11= 0.8 A t 1 =1.5 ms 1 2 = 0.2 A V1 = 24 VDC t 1 3 ms V 2 = 5 VDC I 1 1.0 A t 1 =1.5 ms I 2 = 0.3 A Q Ni/min...

カタログの4ページ目を開く
MATRIX Pneumatic Division - 890 Series High Performance compact solenoid multi-valve - 2/2 NC x 9 - 5

891 2/2 NC DIRECT i PFM PNM PWM CONTROL: N. 1 NC GENERAL CHARACTERISTICS FLUID Non-lubricated dry air, neutral gases (-10 + 50°C) FILTRATION RATIN6 Min 40 micron TEMPERATURE -10 + 50°C (Standard version) RESPONSE TIME IN OPENING 24 < 5 ms XX/KK< 1 ms RESPONSE TIME IN CLOSING 24 < 2 ms XX/KK < 1 ms MAXIMUM FREQUENCY 200 Hz 500 Hz WEIGHT 260 g PRODUCT LIFE EXPECTANCY > 500 M/s cycles IP RATING IP62 IDENTIFICATION CODE M X 8 1 0 0 24 ■I HRSnHI I BBMBHBBmmw OUTLETS FUNCTION 1 Outlet C NC MAXIMUM FLOW RATE (at 6 bar) M 900 N//min 1260 N//min (control tension [XXlfKKl) TYPE 1620 NI/min (control...

カタログの5ページ目を開く
MATRIX Pneumatic Division - 890 Series High Performance compact solenoid multi-valve - 2/2 NC x 9 - 6

ACCESSORIES Rfrence Quantity Description 1 1 Push-in fitting for D.12 tube 2 1 Push-in fitting for D.8 tube Note: Inch size available CHARACTERISTICS OF THE ELECTRICAL CONTROL - MODELS KK CHARACTERISTICS OF THE ELECTRICAL CONTROL - MODELS XX ■ P100% Vp I 1 (V1> Carrent run Pressure run Pressure rurt N.B. KK MODELS ARE CONTROLLED IN TENSION N.B. XX MODELS ARE CONTROLLED IN CURRENT V1 = 24 VDC t1 = 3 ms V2 5 VDC 11= 3.5 A t 1 =1.5 ms I 2 1 A V1 = 24 VDC t 1 V2 = 5 VDC I 1 4.0 A i 1 1.5 ms I 2 1 A FLOW RATE [wf ELECTRICAL PORT CONNECTION Qn = 540 M'/min C = 128 N;'/min bar b = 0.29 COLOUR 1...

カタログの6ページ目を開く
MATRIX Pneumatic Division - 890 Series High Performance compact solenoid multi-valve - 2/2 NC x 9 - 7

893 2/2 NC PFM PNM PWM CONTROL: N. 3 NC GENERAL CHARACTERISTICS FLUID Non-lubricated dry air, neutral gases (-10 + 50°C) FILTRATION RATING Min 40 micron TEMPERATURE - 10 + 50DC (Standard version) RESPONSE TIME IN OPENING 24 < 5 ms XX/KK < 1 ms RESPONSE TIME IN CLOSING 24 < 2 ms XX/KK < 1 ms MAXIMUM FREQUENCY 200 Hz 500 Hz WEIGHT 250 g PRODUCT LIFE EXPECTANCY > 500 M/s cycles IP RATING IP62 IDENTIFICATION CODE M X OUTLETS 0 3 3 Outlets MAXIMUM FLOW RATE (at 6 bar) M 300 NZ/min 420 NZ/min (control tension [XX][KK\ 520 NZ/min (control tension | XX |[KKl) CONTROL TENSION 24 24 VDC ± 10% 2.9-...

カタログの7ページ目を開く
MATRIX Pneumatic Division - 890 Series High Performance compact solenoid multi-valve - 2/2 NC x 9 - 8

n.2 M5 depth 6mm. ACCESSORIES Rfrence Quantity Description 1 1 Push-in fitting for D.12 tube 1 Push-in fitting for D.6 tube Note: Inch size available CHARACTERISTICS OFTHE ELECTRICAL CONTROL - MODELS KK CHARACTERISTICS OF THE ELECTRICAL CONTROL - MODELS XX ftp + P100% Pressure run 驗 H <V1) n.B. kk models are controlled in tension N.B. XX MODELS ARE CONTROLLED IN CURRENT V1 = 24 VDC t 1 = 2 ms V2 = 5 VDC 1 1 t 1 1.5 ms 0.3 A 24 VDC t 1 2.5 ms V2 5 VDC 1 = 1.5 A t 1 1.5 ms I 2 = 0.3 A 24 VDC t 1 =3.5 ms V2 5 VDC 2.8 A t 1 1.5 ms I 2 = 0.3 A FLOW RATE [mJ ELECTRICAL PORT CONNECTION Cm = 190...

カタログの8ページ目を開く
MATRIX Pneumatic Division - 890 Series High Performance compact solenoid multi-valve - 2/2 NC x 9 - 9

899 2/2 NC CONTROL GENERAL CHARACTERISTICS FLUID Non-lubricated dry air, neutral gases (-10 + 50°C) FILTRATION RATING Min 40 micron TEMPERATURE - 10 + 50°C (Standard version) RESPONSE TIME IN OPENING 24 < 5 ms XX/KK < 1 ms RESPONSE TIME IN CLOSING 24 < 2 ms XX / KK < 1 ms MAXIMUM FREQUENCY 200 Hz 500 Hz WEIGHT 210g PRODUCT LIFE EXPECTANCY > 500 M/s cycles IP RATING IP62 IDENTIFICATION CODE RANGE MODELS 0 2-8 bar Ail

カタログの9ページ目を開く
MATRIX Pneumatic Division - 890 Series High Performance compact solenoid multi-valve - 2/2 NC x 9 - 10

INLET-INGRESSO ACCESSORIES Rfrence Quantity Description 1 1 Push-in fitting for D.12 tube CM 1 Push-in fitting for D.4 tube Note: Inch size available CHARACTERISTICS OF THE ELECTRICAL CONTROL - MODELS KK CHARACTERISTICS OF THE ELECTRICAL CONTROL - MODELS XX -P100% l/p + - P 100% M (V1) Current run N.B. KK MODELS ARE CONTROLLED IN TENSION N.B. XX MODELS ARE CONTROLLED IN CURRENT V1 = 24 VDC t 1 2 ms V2= 5 VDC I 1 0.5 A t 1 =1.5 ms I 2 = 0.2 A V1 = 24 VDC t1 = 2 ms V2 = 5 VDC 11= 0.8 A t 1 = 1.5 ms I 2 = 0.2 A V1 = 24 VDC 11 3 ms V2 = 5 VDC 1 1 1.0 A t 1 =1.5 ms I 2 = 0.3 A a N//min 120 FLOW...