カタログの抜粋

LSK LSK D.C. motors 2 to 750 kW Use the complete motor designation when placing your order, see page 160. Simply go through the complete designation step by step. Optional : IP 55 - IC 416 Range identification Frame size IEC 72 No. of poles Stator type and construction code Armature voltage Rated speed Field voltage This document has been translated from the French version which should be used for reference. LEROY-SOMER reserves the right to modify the design, technical specifications and dimensions of the products shown in this catalogue. The descriptions cannot in any way be considered...
カタログの2ページ目を開く
This catalogue gives full information about LEROY-SOMER LSK D.C. motors, 2 to 750 kW. Designed to the latest European standards, this laminated frame motor satisfies most industrial requirements, and sets the standard for the whole of the LEROY-SOMER range of D.C. motors. LEROY-SOMER also produces nonstandard motors and others, providing a range of power from 0.06 kW right up to 18.5 kW. The selection chart can be used to find exactly the right motor for your application. FORCED VENTILATION SELF COOLED PERMANENT MAGNETS WOUND POLES
カタログの3ページ目を開く
LSK D.C. motors Contents PAGES - GENERAL INFORMATION Copyright 2004 : MOTEURS LEROY-SOMER
カタログの4ページ目を開く
LSK D.C. motors Contents PAGES - ELECTRICAL CHARACTERISTICS
カタログの5ページ目を開く
LSK D.C. motors Index PAGES
カタログの6ページ目を開く
LSK D.C. motors Index PAGES
カタログの7ページ目を開く
Enclosed and drip-proof D.C. motors 0.06 to 750 kW Enclosed permanent magnet motor Drip-proof wound motor Enclosed wound motor Drip-proof, force-cooled wound motor
カタログの8ページ目を開く
DELIVERY WITH GUARANTEED AVAILABILITY LEROY-SOMER offer their clients the opportunity to fix their own delivery dates, without prior consultation. Information regarding products & availability can be found in CATALOGUE ref: 3641 or CD Rom ref: 3709 UE es ALOG Y CAT le speed driv ER IV Variab otors ic m Electr GUARA NTEED Availability Guaranteed delivery dates thanks to unique, high performance logistics. Electr DELIVE R ic m otors Y CATA L -Vari able OGUE spee d dri
カタログの9ページ目を開く
LSK D.C. motors General information A1 - Quality commitment LEROY-SOMER's quality management system is based on : - indicators used to monitor procedure performance. - control of procedures right from the initial sales offering until delivery to the customer, including design, manufacturing start-up and production. - corrective actions and advancements with tools such as FMECA, QFD, MAVP, MSP/MSQ and Hoshin type improvement workshops on flows, process re-engineering, plus Lean Manufacturing and Lean Office. - a total quality policy based on making continuous progress in improving...
カタログの10ページ目を開く
A2 - Standards and approvals ORGANIZATION OF STANDARDS AUTHORITIES International bodies: Worldwide General standardization ISO International Standards Organisation Electronics and Electrotechnical Certification IEC International Electrotechnical Commission Europe ECS/CEN European Committee for Standardization ECISS European Committee for Iron and Steel Standards CENELEC European Committee for Electrotechnical Standardization AUSTRALIA BELGIUM CIS (ex-USSR) DENMARK FINLAND FRANCE GERMANY GREAT BRITAIN ITALY JAPAN NETHERLANDS NORWAY SAUDI ARABIA SPAIN SWEDEN SWITZERLAND UNITED STATES DIN/VDE...
カタログの11ページ目を開く
Approvals: Certain countries recommend or insist on approval from national organizations. Approved products must carry the recognized mark on their identification plates. Country Initials Organization USA UL or RJ Underwriters Laboratories CANADA CSA Canadian Standards Association NFEN 60034-5 DIN/EN 60034-5 BS EN 60034-5 UNEL B 1781 International reference standards
カタログの12ページ目を開く
| A2 - Standards and approvalsList of standards quoted in this catalogue JSSS- in International Standards Electrical rotating machines: ratings and operating characteristics. Electrical rotating machines: classification of degrees of protection provided by casings. Electrical rotating machines (except traction): cooling methods. Electrical rotating machines (except traction): symbols for structural shapes and assembly layout. Electrical rotating machines: terminal markings and direction of rotation. Electrical rotating machines: noise limits. Electrical rotating machines: mechanical...
カタログの13ページ目を開く
Tolerances for electromechanical characteristics IEC 60034-1 specifies standard tolerances for electromechanical characteristics. Parameters Tolerances f machines P < 50 kW Efficiency -l machines P > 50 kW Tolerances and adjustments The standard tolerances shown below are applicable to the drawing dimensions given in our catalogues. They fully comply with IEC standard 60072-1. Characteristics Tolerances © Excentricity of shaft in flanged motors Frame size: H < 250 H > 280 Diameter 0 of shaft extension: -11 to 28 mm - 32 to 48 mm - 55 mm and over Diameter N of flange spigot: Key width:...
カタログの14ページ目を開く
A4.1 - ELECTRICITY AND ELECTROMAGNETISM Quantity
カタログの15ページ目を開く
QuantityName French name UnitsSymbol Definition SI Units and expressions not recommended Non SI, but accepted Conversion
カタログの17ページ目を開く
LSK D.C. motors General information A5 - Unit conversions Units Length Mass Torque Force Moment of inertia Power Pressure Magnetic flux Magnetic losses MKSA (international system) 1 m = 3.2808 ft
カタログの18ページ目を開く
LSK D.C. motors General information A6 - Standard formulae used in electrical engineering A6.1 - MECHANICAL FORMULAE Title Definitions / Notes A force F is the product of a mass m multiplied by an acceleration γ Torque (moment) The torque (moment) M of a force in relation to an axis is the product of that force multiplied by the distance r of the point of application of F in relation to the axis. Power P is the quantity of work yielded per unit of time Acceleration time ω = 2π N/60 where N is the speed of rotation in min–1 (rpm) J is the moment of inertia of the system Ma is the moment of...
カタログの19ページ目を開く
A6.2 - MOTOR FORMULAE Title Formula Units Definitions / Notes
カタログの20ページ目を開く
B1 - Definition of "Index of protection" (IP) Indices of protection of electrical equipment enclosures in accordance with IEC 60034-5 - EN 60034-5 (IP) - EN 50102 (IK) First number: protection against solid objects Protection against solid objects of over 50 mm (e.g. accidental hand contact) Protected against vertically dripping water (condensation) Protected against solid objects of over 12 mm 2 Protected against solid objects 3 Protected against water dripping up to 60" from the vertical Protected against solid objects of over 1 mm (e.g. : thin wire) Protected against dust (no...
カタログの21ページ目を開くLEROY-SOMERのすべてのカタログと技術パンフレット
-
FFB brake motors
52 ページ
-
Brake motors range
16 ページ
-
POULIBLOC
8 ページ
-
DYNABLOC
100 ページ
-
MULTIBLOC - IMfinity
88 ページ
-
Cb, Ot, Mub, Mb, FFB
84 ページ
-
LS FFB - LSES FFB
52 ページ
-
asynchrones triphasés
176 ページ
-
INDUCTION MOTORS
60 ページ
-
Industrial Refrigeration
16 ページ
-
Proxidrive
2 ページ
-
Digistart D3
8 ページ
-
Multibloc
2 ページ
-
Training Courses 2018
52 ページ
-
Environmental Policy
2 ページ
-
Port Logistics
20 ページ
-
Hydroelectricity
2 ページ
-
Nuclear Applications
16 ページ
-
Marine Applications
20 ページ
-
Minerals Industry
12 ページ
-
Unimotor
2 ページ
-
LC liquid cooled motors
92 ページ
-
3-phase induction motors
176 ページ
-
Geared motors 3000 Range
16 ページ
-
FFB brake motors
24 ページ