カタログの抜粋

Type Series Booklet 3400.5/6--10 50 Hz Submersible Borehole Pumps Applications -- Drinking and service water supply -- Irrigation and spray irrigation -- Lowering and maintaining ground water levels -- Pressure boosting -- Fountains -- Mining, offshore, tank farms -- Building services systems -- VDS sprinkler systems Operating Data Capacity Q up to 840 m3/h (233 l/s) Head H up to 480 m Temperature of fluid handled t up to +50 °C Speed n 2900 rpm Supply voltage U up to 10,000 V Design Single-- or multistage centrifugal pumps in pump shroud or in ring--section design. Radial or mixed flow hydraulic systems; reduced impeller diameters also available in some cases. The stage casings of radial pumps are connected by metal straps, those of mixed flow pumps by stud bolts. Suction casing fitted between pump and motor. Suction casing equipped with strainer to protect the pump from coarse particles in the fluid. Pumps with check valve or connection branch on option. Available with threaded or flanged end on option. Particularly suitable for vertical installation in narrowdeep wells. Pump Designation (Example) UPA 200 B -- 80 / 5 b Type series Minimum well diameter (mm) (for ex.: 200 mm = 8 inches) Design status Capacity Qopt (m3/h) -- (4 up to 10 inches) 1) (l/s) -- (12 inches and above) Number of stages Reduced impeller diameters 1) UPA 200 -11 + 14: Q in l/s. Motor Designation (Example) UMA 250 D 110 / 2 1 Type series Well diameter (mm) (for ex. 250 mm = 10 inches) Design status Rated power PN (kW) Number of poles Winding insulation Certification Quality management certified to ISO 9001 Submersible Borehole Pumps S 100D, UPA 100C, UPA 150C, UPA 200, UPA 200B, UPA 250C, UPA 300, UPA 350, BSX -- BSF, UPZ Available automation products: • Hyamaster (UPA 200 -- UPA 350) • hyatronic (UPA 200 -- UPA 350) • switch gear (S 100D -- UPA 350) Complete Range The complete submersible borehole pump range comprises pump models for flow rates up to Q = 2500 m3/h (695 l/s) and heads up to H = 1500 m. The submersiblemotor range covers sizes for power ratings up to P = 3500 kW and voltages up to U = 10,000 V for 50 and 60 Hz. In addition, a special range is available which features submersible motors with a higher number of poles.
カタログの1ページ目を開く
50 Hz Submersible Borehole Pumps 2 Contents Page The Submersible Borehole Pump Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operation with Soft Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Operation with Frequency Inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Typical Installation Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Submersible Borehole Pump Selection for Deep Wells . . . ....
カタログの2ページ目を開く
50 Hz Submersible Borehole Pumps 3 What can you expect from the “Submersible Borehole Pumps Booklet”? The information provided can help you make a -- quick -- first rough selection -- on your own to find a suitable KSB submersible borehole pump for your application.We have kept the volume of the catalogue down to what we think is the absolute minimum. For the 4 to 14 inch range, you will find the following information on the pump selected: -- pump series, size and number of stages, -- motor series, size, power, amperage, and allowable temperature, -- starting method, supply voltage and type...
カタログの3ページ目を開く
50 Hz Submersible Borehole Pumps 4 The Submersible Borehole Pump Range " S 100D (4 inch) p. 11 -- 22 " UPA 100C (4 inch) p. 23 -- 32 " UPA 150C (6 inch) p. 33 -- 56 UPA 200 " (8/10 inch) p. 57 -- 65 " UPA 200B (8/10 inch) p. 65 -- 69 UPV 150S (6 inch) on request " UPZ BSX - BSF ( 16 inch) p. 91 -- 98 on request " UPA 300, 350 (12/14 inch) p. 77 -- 90 " UPA 250C (8/10 inch) p. 70 -- 76 " UPV 200 (8 inch) on request
カタログの4ページ目を開く
Voltage [%] Time [s] Run--up Operation Run--down 4s 4s 120 100 80 60 40 20 0 50 Hz Submersible Borehole Pumps 5 Operation of KSB submersible motor pumps with soft starters Soft starter electronically reduce the incoming line voltage and, hence, the initial starting torque and starting current of electric motors. During run--up they gently ramp up the applied voltage to the motor. In the case of submersible motors, the extremely slim design and consequential small moments of inertia result in special characteristics, which differ strongly from normal asynchronous motors. Effects on...
カタログの5ページ目を開く
50 Hz Submersible Borehole Pumps 6 Pump Operation with Frequency Inverter In principle, the motors of submersible borehole pumps can also be run on a frequency inverter. As submersible motors differ from conventional standardized motors in terms of bearings, moment of inertia, insulation, temperature increase, loss distribution and heat distribution, the following parameters must be observed: -- Maximum allowable acceleration time (start ramp) -- Maximum allowable deceleration time (stop ramp) -- Minimum frequency -- Maximum operating frequency -- Maximum permissible voltage increase...
カタログの6ページ目を開く
50 Hz Submersible Borehole Pumps 7 Typical Installation Positions a) Vertical Installation (deep well, pump sump, etc.) CAUTION: The construction of the well head must meet the relevant regulations of the competent authorities! The unitmust never be installed with its suction strainer exactly at the level of the well screen / filter! Before installing the unit in narrow deep wells we recommend to check narrow boreholes for dimensional accuracy over their entire length, e.g. by inserting a pipe of the length and biggest outside diameter of the pump unit. Sharp bends or bottlenecks can make...
カタログの7ページ目を開く
50 Hz Submersible Borehole Pumps 8 Submersible Borehole Pump Selection for Deep Wells Pump Selection The following data are required for a first rough selection of a submersible borehole pump: -- Capacity Q in m3/h (l/s) -- Pressure at well head HA in m -- Well diameter in inches or mm -- Temperature of fluid handled tA in °C -- Pump head HP in m While Q, HA, Dand tA are usually specified by the customer, the head HP to be developed by the pump needs to be calculated. There are two typical applications to be considered (see the drawing on the right): 1. Pumping into an open overhead tank HP...
カタログの8ページ目を開くKSBのすべてのカタログと技術パンフレット
-
RPH
2 ページ
-
HERA-BD
2 ページ
-
SISTO-10
24 ページ
-
BOA-CVE H
2 ページ
-
UPA
104 ページ
-
HPK-L
2 ページ
-
KWP
2 ページ
-
Etachrom L
2 ページ
-
Amarex N
2 ページ
-
Etaline-R
2 ページ
-
BOA-R
16 ページ
-
TRIODIS 150
2 ページ
-
Cervomatic EDP.2
10 ページ
-
Etabloc SYT
2 ページ
-
Type Series Booklet
22 ページ
-
Type Series Booklet
14 ページ
-
ACTELEC 31 to 1600
18 ページ
-
Amaclean
12 ページ
-
Amacan S
2 ページ
-
Amacan P
2 ページ
-
Amacan K
2 ページ
-
Ama-Drainer-Box Mini
2 ページ
-
Ama-Drainer-Box
2 ページ
-
Ama-Drainer® N –
2 ページ
-
Ama-Drainer 80/100
20 ページ
-
LevelControl Basic 2
36 ページ
-
Amar-Drainer 4../5
16 ページ
-
UGS
12 ページ
-
ACTELEC EZ SQ
20 ページ
-
ACTELEC SQ AUMA
14 ページ
-
ACTELEC 31 to 800
12 ページ
-
ACTAIR 1.5 to 1600
20 ページ
-
PumpMeter
12 ページ
-
KSB Sonolyzer
5 ページ
-
Etachrom L
40 ページ
-
Etanorm/Etabloc
70 ページ
-
AKG-A/AKGS-A
12 ページ
-
Amamix
2 ページ
-
Amaprop
2 ページ
-
HQ
2 ページ
-
BOAX-CBV13
3 ページ
-
Ama-Porter F, S
2 ページ
-
Magnochem
2 ページ
-
Secochem Ex
2 ページ
-
Hya-Solo D
44 ページ
-
HGB, HGC
4 ページ
-
GZ 9
2 ページ
-
Etaseco
2 ページ
-
Etanorm
2 ページ
-
Etaline
2 ページ
-
CTN / -H
2 ページ
-
CINCP / CINCN
2 ページ
-
CHTC
2 ページ
-
Calio S
2 ページ
-
AMADS
2 ページ
-
Ama-Drainer Box
2 ページ
-
YNK
2 ページ
-
RHR/RVR
2 ページ
-
RHM
2 ページ
-
HGC
2 ページ
-
CHTD
2 ページ
-
Danais 150/300
2 ページ
-
RPHb
2 ページ
-
MegaCPK
2 ページ
-
RPH-V
2 ページ
-
RDLO
2 ページ
-
Multitec
2 ページ
-
INVCP
2 ページ
-
SuPremE
2 ページ
-
The New Calio. Expertise
16 ページ
-
SALINO® Pressure Center
12 ページ
-
The Range of Valves
74 ページ
-
Pumps and Automation
66 ページ
カタログアーカイブ
-
Handle S series
8 ページ
-
MR 25 to 1600
16 ページ
-
MN
4 ページ
-
MA
4 ページ
-
ENNACTO 200 to 12500
20 ページ
-
DYNACTO 12 to 400
16 ページ
-
ACTO 25 to 12500
16 ページ
-
ACTAIR 1,5 to 1600
20 ページ
-
MAT-P
4 ページ
-
BOA-CVE
16 ページ
-
SICCA GTF 800-2500
8 ページ
-
VTS
4 ページ
-
BOA-RVK
4 ページ
-
BOA-Control IMS
8 ページ
-
HERA BD
6 ページ
-
ZJSVA/ ZXSVA
6 ページ
-
BOACHEM
4 ページ
-
BOA-H
2 ページ
-
BOA-SuperCompact
8 ページ
-
LSA-S
4 ページ
-
HGM
4 ページ
-
Trialine
12 ページ
-
Trialine Z
12 ページ
-
Riovar/Riovar Z
16 ページ
-
Rio-Eco/Z
24 ページ
-
Riotherm
4 ページ
-
Rio/Rio Z
32 ページ
-
PHZ
15 ページ
-
Ixo
4 ページ
-
CTN
4 ページ
-
Ama-Porter
24 ページ
-
Ama-Porter ICS
16 ページ
-
Brochure HPK / HPK-L
4 ページ
-
SPY-2-Page Product
2 ページ
-
Amaprop
4 ページ
-
Omega / Omega V
56 ページ
-
Type series booklet CPKN
16 ページ