AFC 030 Converter
1 / 32ページ

{{requestButtons}}

カタログの抜粋

AFC 030 Converter - 1

Technical Datasheet Electromagnetic flow converter • Designed and tested for industrial nuclear applications • Free of programmable electronic components • LED bar flow indication The documentation is only complete when used in combination with the relevant documentation for the .

カタログの1ページ目を開く
AFC 030 Converter - 3

PRODUCT FEATURESD 1.1 Solution for nuclear environments The AFC 030 electromagnetic flow converter is designed to measure flow velocity of electrically conductive liquids in radiation areas, for both safety as non-safety applications. The AFC 030 can be combined with two types of measuring sensors: POWERFLUX 4000 and POWERFLUX 5000. For maximum reliability and durability the AFC 030 does not contain any programmable electronic components (PEC). It features an adjustable flow range. The flow is indicated as a percentage of the maximum flow with the LED bar or with a 4 - 20 mA output. Figure...

カタログの3ページ目を開く
AFC 030 Converter - 4

nPRODUCT FEATURES Highlights • Free of programmable electronic components • Flow indication as percentage of maximum flow - LED bar on the front - 4 - 20 mA output • Adjustable flow range Industries • Nuclear Applications • Cooling water • Transport water • Borated water • Spent resin

カタログの4ページ目を開く
AFC 030 Converter - 5

PRODUCT FEATURESD 1.2 Options and variants The AFC 030 is available in wall mount version only. It can be combined with two types of flow sensors: POWERFLUX 4000 and POWERFLUX 5000. 1.2.1 Signal converter/flow sensor combination possibilities Flow sensor

カタログの5ページ目を開く
AFC 030 Converter - 6

1.3 Measuring principle An electrically conductive fluid flows inside an electrically insulated pipe through a magnetic field. This magnetic field is generated by a current, flowing through a pair of field coils. Inside of the fluid, a voltage U is generated: U=v*k*B*D in which: v = mean flow velocity k = factor correcting for geometry B = magnetic field strength D = inner diameter of flowmeter The signal voltage U is picked off by electrodes and is proportional to the mean flow velocity v and thus the flow rate Q. A signal converter is used to amplify the signal voltage, filter it and...

カタログの6ページ目を開く
AFC 030 Converter - 7

TECHNICAL DATA 2 2.1 Technical data • The following data is provided for general applications. If you require data that is more relevant to your specific application, please contact us or your local sates office. • Additional information [certificates, special tools, software,...) and complete product documentation can be downloaded free of charge from the website (Downtoadcenter). Measuring system

カタログの7ページ目を開く
AFC 030 Converter - 8

2 TECHNICAL DATA Operating conditions

カタログの8ページ目を開く
AFC 030 Converter - 9

TECHNICAL DATA 2Electrical connection General AH outputs are electrically isolated from each other and from all other circuits.

カタログの9ページ目を開く
AFC 030 Converter - 10

2 TECHNICAL DATA2.2 Dimensions and weightsWall version housing weight approximately ; 2.4 kg / 5.3 lb

カタログの10ページ目を開く
AFC 030 Converter - 11

TECHNICAL DATA 22.3 Flow tablesFlow rate in m/s and m3/h

カタログの11ページ目を開く
AFC 030 Converter - 12

2 TECHNICAL DATAFlow rate in ft/s and US gallons/min

カタログの12ページ目を開く
AFC 030 Converter - 13

2.4 Measurement accuracy Every electromagnetic flowmeter is calibrated by direct volume comparison. The wet calibration validates the performance of the flowmeter under reference conditions against accuracy limits. The accuracy limits of electromagnetic flowmeters are typically the result of the combined effect of linearity, zero point stability and calibration uncertainty. Reference conditions Medium: water Temperature: +5...+35°C / +41...+95°F Operating pressure: 0.1...5 barg / 1.5...72.5 psig Inlet section: ≥ 5 DN Outlet section: ≥ 2 DN Figure 2-1: X [m/s] : flow velocity Y [%]:...

カタログの13ページ目を開く
AFC 030 Converter - 14

3.1 Intended use Responsibility for the use of the measuring devices with regard to suitability, intended use and corrosion resistance of the used materials against the measured fluid lies solely with the operator. The manufacturer is not liable for any damage resulting from improper use or use for other than the intended purpose. The electromagnetic flowmeter is designed exclusively to measure the flow of electrically conductive, liquid media. 3.2 Installation specifications The following precautions must be taken to ensure reliable installation. • Make sure that there is adequate space to...

カタログの14ページ目を開く
AFC 030 Converter - 15

3.3 Mounting the wall-housing, remote version Assembly materials and tools are not part of the delivery. Use the assembly materials and tools in compliance with the applicable occupational health and safety directives. Figure 3-1: Pipe mounting of the wall-mounted housing 1 Fasten the mounting plate to the pipe with standard U-bolts, washers and fastening nuts. 2 Screw the signal converter to the mounting plate with the nuts and washers. Figure 3-2: Wall mounting of the wall-mounted housing 1 Prepare the holes with the aid of the mounting plate. For further information refer to Mounting...

カタログの15ページ目を開く
AFC 030 Converter - 16

Mounting multiple devices next to each other 3.3.3 Mounting plate of wall-mounted housing

カタログの16ページ目を開く
AFC 030 Converter - 17

Cover for terminal compartments Terminal compartment for measuring sensor Terminal compartment for outputs Terminal compartment for power supply with safety cover (shock-hazard protection) Cable entry for electrode cable Cable entry for field current cable Cable entry for output Cable entry with blanking plug Cable entry for power supply 1 Turn lock to the right and open the cover. 2 Open safety cover (lid) to enter terminal connections of measuring sensor 3 Open safety cover (lid) to enter terminal connections of mains power supply Be aware that the cable, type L45551 has a minimal bending...

カタログの17ページ目を開く
AFC 030 Converter - 18

4.1 Safety instructions All work on the electrical connections may only be carried out with the power disconnected. Take note of the voltage data on the nameplate! Observe the national regulations for electrical installations! Observe without fail the local occupational health and safety regulations. Any work done on the electrical components of the measuring device may only be carried out by properly trained specialists. Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. 4.2 Important...

カタログの18ページ目を開く
AFC 030 Converter - 19

ELECTRICAL CONNECTIONS 4 4.3 Electrical cables for remote device versions 4.3.1 Notes on signal and field current cables Observe the following notes: • Place the signal cable with fastening elements. • It is permissible to lay the signal cable in water or in the ground. • Cable specifications have to comply to CST 74C068 standard • The connection of the inner shield is carried out via the stranded drain wire. Requirements for signal cables provided by the customer If the signal cable was not ondened, it is to be pnovided by the customer. The following requirements regarding the electrical...

カタログの19ページ目を開く

KROHNE Messtechnik GmbHのすべてのカタログと技術パンフレット

  1. TIDALFLUX 2300 F

    24 ページ

  2. OPTISONIC 8300

    40 ページ

  3. OPTIBAR LC 1010

    20 ページ

  4. DWM1000/DWM2000

    20 ページ

  5. DW 181

    28 ページ

  6. Flow measurement

    72 ページ

  7. HYG.Accessories

    24 ページ

  8. IFC 050 Handbook

    84 ページ

  9. IFC 050

    32 ページ

  10. BATCHFLUX 5500 C

    28 ページ

  11. Optimass 2000

    2 ページ

  12. C95 CI

    4 ページ

  13. Product Overview

    64 ページ

  14. BM 500

    16 ページ

  15. H250 M40

    48 ページ

  16. OPTIFLUX 1000

    24 ページ

  17. IFC 100

    36 ページ

  18. H250 M40

    20 ページ

  19. SMARTPAT Overview

    16 ページ

  20. WATERFLUX 3070

    24 ページ

  21. Temperature Catalogue

    148 ページ

  22. Water & Wastewater

    44 ページ

  23. Food Applications

    100 ページ

  24. OPTITEMP TT 51

    2 ページ

  25. OPTIWAVE 5200

    2 ページ

  26. OPTIWAVE 6300

    2 ページ

  27. Energy (Oil & Gas)

    44 ページ

  28. VISCOLINE

    2 ページ

  29. OPTISONIC 7300

    2 ページ

  30. OPTIFLEX 2200

    2 ページ

  31. BM 26

    2 ページ

  32. OPTISONIC 3400

    16 ページ

  33. OPTIMASS 6400

    16 ページ

  34. MICRO-SET

    12 ページ

  35. IFC 100 | IFC 300

    9 ページ

  36. ALTOSONIC V12

    18 ページ

  37. OPTITEMP TR | TC 100

    28 ページ

  38. IFC 300 Converter

    56 ページ

  39. DW 18 SERIES

    28 ページ

  40. Brochure Bioenergy

    12 ページ

カタログアーカイブ

  1. CARGOMASTER

    16 ページ

  2. DWM 1000 | 2000

    20 ページ

  3. UFM 3030

    16 ページ

  4. TR TC

    28 ページ