カタログの1ページ目を開くWe bring quality to light. Features at a glance Cost-effective and robust CCD spectrometer technology Standard USB interface Compatible with all Instrument Systems measuring adapters Different models for UV / VIS / NIR spectral range Optimized for spectroradiometry and spectrophotometry Easy operation using SpecWin Light software DLL and LabVIEW driver available for writing custom software MAS 40: A high-quality spectrometer worth the money Have you been looking for a value-for-money spectrometer that delivers quality and precision? Then the MAS 40 Mini-Array Spectrometer is just what you...
カタログの2ページ目を開くLED measurement Instrument Systems has developed a complete entry level model for the measurement of LEDs which is based on Light can also be operated by semi-skilled personnel, e.g. in quality assurance. LED Station - The complete solution for testing LEDs A variety of measurement adapters that can be mounted to the stable input port of the MAS 40, transform the MiniArray-Spectrometer into the LED Station. The LED station is a cost-effective spectrometer system for fast and easy measurements of all optical parameters of an LED: Luminous intensity [cd] and Luminous flux [lm] Color...
カタログの3ページ目を開くWe bring quality to light. Mesurement of luminous flux - the integrating sphere adapter ISP 75 The Mini-Goniophotometer is controlled by the software via an USB interface. The ISP75 integrating sphere adapter is available for measuring luminous flux and radiant power. The LED test fixture is used to push the LED into the opening of the sphere in such a way that the light radiation is captured by the integrating sphere. The interior of the integrating sphere has a highly reflective and diffusing white coating for this purpose. All LED test fixtures from Instrument Systems can be used with...
カタログの4ページ目を開くTechnical specifications for LED measurements: Spectrometer Model Spectral range Spectral resolution Stray light (for LEDs) *1 Sensitivity range*2 Luminous intensity (ILED-B) Measurement accuracy*3 Luminous intensity Luminous flux Dominant wavelength LED40-400 Mini-Goniophotometer Angular range in theta axis Angular resolution Angular accuracy LED-720 Current source Current range Measured at 100nm distance to the left of the peak wavelength, relative to the peak intensity of the unweighted spectral data Measured at 600 nm wavelength, a signal-to-noise ratio of 10:1, and without averaging...
カタログの5ページ目を開くWe bring quality to light. Technical specifications Model Spectral range Spectral resolution Stray light (broadband with standard illuminant A) *2 General Detector Integration time Spectroradiometry Sensitivity range for irradiance *3 Signal sensitivity at 1 s integration time *3 Spectrophotometry Baseline noise *5 Photometric transmission accuracy *6 Miscellaneous Interface Power consumption Ambient conditions Applies to penray lamp or laser Measured with 455 nm cut filter Measured with EOP120 and OFG424 fiber bundle at 500 nm wavelength, a signal-to-noise ratio of 10:1 and without...
カタログの6ページ目を開くOrdering information Order No. Spectral range Spectrometer Spectral resolution Data point interval Density 1 filter (reduces signal level nominally by a factor of 10) Density 2 filter (reduces signal level nominally by a factor of 100) UV density 1 filter (reduces signal level nominally by a factor of 10) SpecWin Light spectral software for Windows XP/Vista SpecWin Pro high-end spectral software for Windows XP/Vista Windows DLL for custom software development LabVIEW driver (requires SW-251 DLL) ILED-B Luminous intensity adapter; spectral range 320 nm – 950 nm ILED-B Luminous intensity...
カタログの7ページ目を開くWe bring quality to light. light measurement Instrument Systems GmbH Neumarkter Str. 83, 81673 Munich, Germany Tel.: +49 89 45 49 43 - 0 Fax: +49 89 45 49 43 - 11 E-mail: info@instrumentsystems.com www.instrumentsystems.com
カタログの8ページ目を開くKonica Minolta Sensing Americasのすべてのカタログと技術パンフレット
-
LumiTop Series
16 ページ
-
LumiSuite
8 ページ
-
CAS140D_IR
2 ページ
-
CAS140CT_IR
8 ページ
-
CAS125
4 ページ
-
LumiCam 4000B_2400B_V2
12 ページ
-
ISP Series
16 ページ
-
DTS 140D NVIS
5 ページ
-
ACS & ACU Series
12 ページ
-
LGS 650
8 ページ
-
LumiCam Series
16 ページ
-
CAS 120
8 ページ
-
CAS 140D
16 ページ
-
New GM series gloss
4 ページ
-
Chroma Meter CS-150
3 ページ
-
CHROMA METER CS-200
6 ページ
-
Chroma Meter CL-200A
4 ページ
-
GTI GLE-M
2 ページ
-
Rhopoint TAMS™
6 ページ
-
Rhopoint IQ FLEX 20
2 ページ
-
Uni Gloss 60A/S/CT
4 ページ
-
BC-10 Plus
4 ページ
-
CR-410PB
4 ページ
-
CR-400/410
5 ページ
-
CM-3700A
3 ページ
-
CM-700d/600d
3 ページ
-
cm-25cg
2 ページ
-
cm-m6
2 ページ
-
DTS140 NVIS
6 ページ
-
Rhopoint IQ-S
4 ページ
-
LumiCam 2400
4 ページ
-
CM-25cG
4 ページ
-
FD-9
6 ページ
-
CR-20
2 ページ
-
CR-10 Plus
2 ページ
-
LCS IV
1 ページ
-
ISP40
4 ページ
-
LGS 1000
4 ページ
-
LGS 350
8 ページ
-
ISP 500
4 ページ
-
ISP 2000
2 ページ
-
ISP 150L
2 ページ
-
ISP 1000
4 ページ
-
LED-81X/-850
4 ページ
-
ACS-530
4 ページ
-
LED 25
4 ページ
-
LSM 350
4 ページ
-
THE DTS 400 SYSTEM
2 ページ
-
LUMICAM 1300
8 ページ
-
CAS 140CTS
4 ページ
-
SPECTRO 320
12 ページ
-
CR-410C Coffee
2 ページ
-
MULTI GLOSS 268PLUS
2 ページ