Economical Temperature Control Optimal temperature control of reactors Temperature Control in pharmaceutical and chemical laboratories as well as pilot plants and industrial processes requires of highly dynamic temperature control systems. When controlling reactors, endothermic and exothermic reactions must be compensated for with extreme speed and reliability. When specifying the most suitable temperature control system a variety of conditions and influences must be taken into consideration. This article provides criteria and advice for choosing the most effective and most efficient solution for your applications. Most temperature control applications involve reactors made of glass or steel. Steel reactors are more robust and durable. Glass reactors allow the chemist to view processes within the reactor. However, glass reactors require extenisve safety precautions for safe use. Reactors generally have an inner vessel containing the samples which require temperature control. The inner vessel is surrounded by a jacket which contains heat-transfer liquid. The temperature control system is connected to the reactor jacket. To control the temperature of a reactor, the temperature control system continuously pumps the heat-transfer liquid through the jacket of the reactor. Sudden changes in temperature within the reactor are dynamically balanced by rapid heat-up or cool-down. The liquid is heated or cooled within the temperature control system. A simplified temperature control system is shown on the right. Functional view of reactor temperature control Temperature control system control electronics Examples for applications of reactors • Mini plants, pilot plants (e.g. pharmaceutical, chemical industries) • Material stress tests (e.g. automotive and aircraft industries, space exploration) • Temperature simulation reactor jacket loop circuit heat transfer liquid heat exchanger Whitepaper „Optimale Temperierlosung
カタログの1ページ目を開く
When choosing a highly dynamic temperature control system, a variety of conditions and influential factors must be taken into consideration. The aim must be to find the most effective and efficent temperature control for the intended application while assuring optimum functionality. The following chart depicts the range of possible outcomes. We will now discuss each of these factor in detail. Process stability Materials and reactor design have a significant influence on the temperature control of highly dynamic reactor systems. Of course, a glass walled vessel will transfer heat differently...
カタログの2ページ目を開く
The temperature control system‘s integrated pump must be powerful enough to achieve the required flow rates at constant pressure. The pump should provide the required pressure quickly and with maximum control to avoid exceeding the pressure limit values mentioned before. Regulation of pump capacity should be made in steps or by presetting a limit value. Pressure specifications and operating conditions of the reactor must always be considered. Advanced temperature control systems feature pumps that automatically and dynamically balance changes of the viscosity of the heat transfer liquid to...
カタログの3ページ目を開く
properly evaluate the size of a temperature-control system, you must look beyond just the footprint. It is absolutely essential to consider how much space will be needed for connections and adequate airflow. A space-optimized temperature control system will have as many connections and ventilation openings on the front and rear sides as possible. Units designed in this way will save you valuable space by allowing you to place additional laboratory devices directly next to the temperature-control system. Poorly designed units will require you to reserve additional space that must be kept...
カタログの4ページ目を開く
It is common practice in laboratories to conduct a series of experiments under identical temperature conditions. Even failed experiments usually must be repeated precisely under the same control parameters. The temperature-control system should contain functions that enable precise reproducibility in these situations. These functions simultaneously lower the expense of generating documentation for an experiment. Although temperature-control systems are increasingly equipped with intuitive operating functions, it is still advisable to inquire about user training from the manufacturer of the...
カタログの5ページ目を開く
User-related aspects ■ Calculate the required cooling/heating capacity ^ Tip: Ask the manufacturer to calculate the correct cooling/heating capacity! ■ Compare the required working temperatures with the working temperature range of the temperature-control solution ^ Tip: Ask the manufacturer for assistance! ■ Observe the pressure values and operating conditions of the reactor ■ Ensure thorough mixing in the reactor Whitepaper „Optimale Temperierlosung
カタログの6ページ目を開く
User-related aspects ■ Preventative maintenance tasks ■ Regularly-scheduled cleaning ^ Tip: Check the manufacturer's service and support offerings! ■ Consider technical requirements and conditions needed at installation site, i.e. power connection Whitepaper „Optimale Temperierlosung
カタログの7ページ目を開く
User-related aspects ■ Operator must observe Machinery Directive ■ User must be trained and have the necessary skills and knowledge ^ Tip: Ask the manufacturer about user training! Whitepaper „Optimale Temperierlosung
カタログの8ページ目を開くJULABO GmbH/ユラボのすべてのカタログと技術パンフレット
-
DYNEO
34 ページ
-
MAGIO
28 ページ
-
CORIO Brochure English
50 ページ
-
JULABO Product Portfolio
32 ページ
-
PURA 10 Brochure en
12 ページ
-
PURA 4 Brochure en
12 ページ
-
PURA 30 Brochure en
12 ページ
-
PURA 14 Brochure en
12 ページ
-
DYNEO Brochure
34 ページ
-
PURA 22 Brochure en
12 ページ
-
CORIO Brochure English
50 ページ
-
JULABO Productportfolio
28 ページ
-
JULABO-TopTech
64 ページ
-
Booster pump
2 ページ
-
JULABO Booster Pump
2 ページ
-
JULABO WirelessTEMP
24 ページ
カタログアーカイブ
-
DYNEO Brochure english
18 ページ
-
DYNEO DD-BC4 Brochure en
16 ページ
-
DYNEO DD-BC6 Brochure en
16 ページ
-
FX30 Brochure en
4 ページ
-
DYNEO Brochure english
34 ページ
-
JULABO-DYNEO-Broschuere
20 ページ
-
DYNEO™
20 ページ
-
JULABO Brochure EN
178 ページ
-
JULABO PURA Water Baths
12 ページ