HQ Series VANE PUMPS
カタログの1ページ目を開く
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS “HQ” SERIES The design of the HQ series vane pumps makes them particularly suitable for application on trucks, especially garbage compactors. All the components subject to wear are contained in a cartridge unit that can be easily removed for inspection and/or replacement without disconnecting the pump from the circuit, drastically reducing expensive machine downtime. The special design of the inner flexible plates of the cartridge enables any thermal expansion in the rotor to be compensated for and to adequately cope with any sudden change in...
カタログの2ページ目を開く
General description Fixed displacement vane pump, hydraulically balanced, with capacity determined by the type of cartridge used and the speed of rotation. The pump is available in five different displacements from 39 to 66 l/min (from 10 to 17 gpm) at 1000 rpm and 7 bar. Technical characteristics Cartridge model Geometric displacement Maximum pressure Hydraulic fluids: mineral oils, phosphate ester based fluids. Viscosity range (with mineral oil): from 13 to 860 cSt. (13 to 54 cSt. recommended). Filtration: for the inlet - 149 micron abs., for the return line - 25 micron abs. or better...
カタログの4ページ目を開く
Main operating data max pressure / hydraulic fluid Antiwear industrial Syntetic fire resistant fluid peak pres. (0,5 sec.max) max Speed / hydraulic fluid (with 0 barm the intake pipe) Antiwear industrial Syntetic fire resistant fluid If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to apply to the maximum speed. max speed / intake pipe pressure Intake pipe pressure (BAR)
カタログの5ページ目を開く
single pump HQ02 Cartridge A02-12 power / pressure input torque / pressure Oil viscosity: 25 c.St. (10W) Temperature: 45°C Inlet pressure: 0 BAR Cartridge A02-14 flow / pressure 725 power / pressure input torque / pressure Oil viscosity: 25 c.St. (10W) Temperature: 45°C Inlet pressure: 0 BAR
カタログの6ページ目を開く
single pump HQ02 Cartridge A02-17 flow / pressure 725 power / pressure input torque / pressure Oil viscosity: 25 c.St. (10W) Temperature: 45°C Inlet pressure: 0 BAR Cartridge A02-19 flow / pressure 725 power / pressure input torque / pressure Oil viscosity: 25 c.St. (10W) Temperature: 45°C Inlet pressure: 0 BAR
カタログの7ページ目を開く
flow / pressure power / pressure input torque / pressure Installation dimensions mm (inches) DPTIDNAL OUTLET
カタログの8ページ目を開く
single pump HQ02 Model code breakdown HQ Pump series Design Seals Pump type (omit with standard seals and shaft-seals in NBR) V = seals and shaft-seals in FPM (Viton®) Outlet port positions (outlet viewed from cover end) A = Outlet opposite end B = Outlet 90° CCW from inlet C = Outlet inline with inlet D = Outlet 90° CW from inlet (viewed from shaft end) L = left hand rotation CCW (omit if CW) Outlet port connection Shaft end 50 = Splined shaft with ISO 14 four holes flange (omit if GAS threaded ) S = SAE port with 4 holes connection PORT ORIENTATIONS
カタログの9ページ目を開く
Shaft seal Parts seals + 2 shaft seals seals + 2 shaft seals Id. codes of pump components
カタログの10ページ目を開く
General description Fixed displacement vane pump, hydraulically balanced, with capacity determined by the type of cartridge used and the speed of rotation. The pump is available in two different displacements from 75 to 88 l/min (from 20 to 23 gpm) at 1000 rpm and 7 bar. Technical characteristics Cartridge model Geometric displacement Maximum pressure Hydraulic fluids: mineral oils, phosphate ester based fluids. Viscosity range (with mineral oil): from 13 to 860 cSt. (13 to 54 cSt. recommended). Filtration: for the inlet - 149 micron abs., for the return line - 25 micron abs. or better...
カタログの11ページ目を開く
single pump HQ03 Main operating data max pressure / hydraulic fluid max speed / hydraulic fluid 3625 2900 (with 0 bar in the intake pipe) Antiwear industrial hydraulic oil Syntetic fire resistant fluid Antiwear industrial hydraulic oil Syntetic fire resistant fluid peak pres. (0,5 sec.max) If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to apply to the maximum speed. max speed / intake pipe pressure % connection factor for the max speed Intake pipe pressure (BAR) power / pressure input torque / pressure Oil viscosity: 25 c.St. (10W)...
カタログの12ページ目を開く
single pump HQ03 Cartridge A03-28 power / pressure input torque / pressure Oil viscosity: 25 c.St. (10W) Temperature: 45°C Inlet pressure: 0 BAR Installation dimensions mm (inches)
カタログの13ページ目を開く
single pump HQ03 Model code breakdown HQ Pump series Design Seals Pump type (omit with standard seals and shaft-seals in NBR) V = seals and shaft-seals in FPM (Viton®) Outlet port positions (outlet viewed from cover end) A = Outlet opposite end B = Outlet 90° CCW from inlet C = Outlet inline with inlet D = Outlet 90° CW from inlet (viewed from shaft end) L = left hand rotation CCW (omit if CW) Outlet port connection Shaft end 50 = Splined shaft with ISO 14 four holes flange (omit if GAS threaded ) S = SAE port with 4 holes connection PORT ORIENTATIONS
カタログの14ページ目を開く
PART NO. PUMP ROTAT. A0324030 right hand A0328070 A0324040 left hand A0328080 Shaft seal Parts seals + 2 shaft seals seals + 2 shaft seals Id. codes of pump components
カタログの15ページ目を開く
General description Fixed displacement vane pump, hydraulically balanced, with capacity determined by the type of cartridge used and the speed of rotation. The pump is available in several versions with rated capacities from 46 to 111 l/min (from 12 to 29 gpm) at 1000 rpm and 7 bar. Technical characteristics Cartridge model Geometric displacement Maximum pressure Hydraulic fluids: mineral oils, phosphate ester based fluids. Viscosity range (with mineral oil): from 13 to 860 cSt. (13 to 54 cSt. recommended). Filtration: for the inlet - 149 micron abs., for the return line - 25 micron abs. or...
カタログの16ページ目を開く
double pump HQ21 Main operating data max pressure / hydraulic fluid max speed / hydraulic fluid 2500 (with 0 bar in the intake pipe) Antiwear industrial hydraulic oil Antiwear industrial hydraulic oil Syntetic fire resistant fluid Syntetic fire resistant fluid cart 12, 14 peak pres. (0,5 sec.max) If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to apply to the maximum speed. max speed / intake pipe pressure % connection factor for the max speed Intake pipe pressure (BAR) power / pressure input torque / pressure Oil viscosity: 25 c.St....
カタログの17ページ目を開くJbj Techniques Limitedのすべてのカタログと技術パンフレット
-
PUMP DRIVE COMPONENTS
61 ページ
-
Shaft locking devices
92 ページ
-
S-Flex Couplings
32 ページ
-
Hydraulic Gear Motors
56 ページ
-
Planetary Gearboxes
48 ページ
-
This is what we do
1 ページ
-
HQ series vane pumps
48 ページ
-
Pneumatic Starters
6 ページ
-
Gear pump summary
12 ページ
-
FLUID POWER ACCESSORIES
66 ページ
-
F15 Ferra Series
20 ページ
-
KT Pressure Switch
8 ページ
-
W Series
8 ページ
-
GPA Series
18 ページ
-
jbj Coolers Summary
2 ページ
-
PIPE FLANGES PORT FLANGES
102 ページ
-
TANKS / RESERVOIRS
22 ページ
-
PRESSURE INTENSIFIERS
22 ページ
-
SCREW PUMPS
50 ページ
-
SCREW PUMP RELIEF VALVES
14 ページ
-
BV Series VANE PUMPS
94 ページ
-
BQ Series VANE PUMPS
108 ページ
-
All steel gear couplings
26 ページ
-
This is jbj Techniques!
28 ページ
-
Vane pumps
10 ページ
-
Fluid power accessories
54 ページ
-
Fluid reservoirs
22 ページ
-
pressure intensifiers
22 ページ
-
screw pumps
50 ページ
-
Torsional couplings
48 ページ
-
jbj PRODUCT SUMMARY
6 ページ
-
PDC
58 ページ