RF - Guide
1 / 159ページ

{{requestButtons}}

カタログの抜粋

RF - Guide - 1

WAIVER It is exclusively in written agreements that we provide our customers with warrants and representations as to the technical specifications and/or the fitness for any particular purpose. The facts and figures contained herein are carefully compiled to the best of our knowledge, but they are intended for general informational purposes only. HUBER+SUHNER is certified according to ISO 9001, ISO 14001, ISO/TS 16949 and IRIS.

カタログの1ページ目を開く
RF - Guide - 2

HUBER+SUHNER® RF CONNECTOR GUIDE Understanding connector technology Published by HUBER+SUHNER (www.hubersuhner.com)

カタログの2ページ目を開く
RF - Guide - 3

HUBER+SUHNER RF CONNECTOR GUIDE 4th edition, 2007 HUBER+SUHNER® is a registered trademark of HUBER+SUHNER AG Copyright© HUBER+SUHNER AG, 1996 Published in Switzerland by HUBER+SUHNER AG, Switzerland All rights reserved. In particular no part of this publication may be reproduced, stored, or translated, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise without the prior written permission of HUBER+SUHNER AG. Request of reproduction must be addressed to HUBER+SUHNER AG, CEO. Document no. 648116 Printed in Switzerland

カタログの3ページ目を開く
RF - Guide - 4

PREFACE After having been in the RF Interconnection Market for more than fifty years, we felt the need to provide our business associates around the world with a booklet containing key information on coaxial connectors. Today, key concepts behind RF technology have not changed much - and this is what this booklet, the HUBER+SUHNER RF CONNECTOR GUIDE, is all about. It contains HUBER+SUHNER know how and experience in the field of connectors. Primarily, we aim this booklet at non-technically and technically skilled people who are daily confronted with purchasing, distributing or maybe...

カタログの4ページ目を開く
RF - Guide - 5

The company portrait is also included in this booklet if further information about our company is desired. Finally, a separate formula booklet is enclosed in the pocket at the back cover of this booklet. It contains all equations described in the GUIDE. Among other things, it includes conversion tables to convert reflection quantities into, say, return loss. I hope you will find the HUBER+SUHNER RF CONNECTOR GUIDE as useful as we wanted it to be. HUBER+SUHNER AG July 2007 HUBER+SUHNER CONNECTOR GUIDE

カタログの5ページ目を開く
RF - Guide - 6

CHAPTER 1: INTRODUCTION TO BASIC RF THEORY . . . . . . . . . . . 9 CHAPTER 2: MATERIALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 CHAPTER 3: RF CONNECTOR DESIGN . . . . . . . . . . . . . . . . . . . . 59 CHAPTER 4: TESTS AND MEASUREMENTS . . . . . . . . . . . . . . . . 109 CHAPTER 5: APPENDICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 CHAPTER 6: REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 CHAPTER 7: INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 CHAPTER 8: NOTES . . . . . . . . ....

カタログの6ページ目を開く
RF - Guide - 7

INTRODUCTION TO BASIC RF THEORY DEFINITION AND GRADUATION OF HIGH FREQUENCY . . . . . . . . . . . . 9 1.1.1 CONSTRUCTION AND FUNCTION OF RF LINES . . . . . . . . . . . . . . . . . . 11 1.2.1 Electromagnetic Field along a RF Line . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Resistances and Reactances in a RF Line . . . . . . . . . . . . . . . . . . . . . . . . . 15 Characteristic Impedance of a low-loss Line at High Frequencies . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Relationship between Frequency and Wavelength . . . . . . . . 20 Influence of Dielectric Material...

カタログの7ページ目を開く
RF - Guide - 8

INTRODUCTION TO BASIC RF THEORY ATTENUATION LOSS OF RF LINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 1.4.1 Determination of the Attenuation Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Attenuation Loss Components of Conductor and Dielectric . . . . . . . . . . . 32 HUBER+SUHNER CONNECTOR GUIDE

カタログの8ページ目を開く
RF - Guide - 9

INTRODUCTION TO BASIC RF THEORY DEFINITION AND GRADUATION OF HIGH FREQUENCY In this first chapter, the main emphasis is laid on explanations to typical parameters in the theory of RF transmission lines, containing coaxial connectors and cables. It should give an impression of how and why transmission lines perform as they do. At the same time, it should provide the reader with fundamental knowledge of common RF techniques including equations, thought as a help or base for the following chapters. In the first section of this chapter, we try to define what high frequency is compared to low...

カタログの9ページ目を開く
RF - Guide - 10

INTRODUCTION TO BASIC RF THEORY High frequency begins where currents and voltages become frequency dependent or where the wavelength becomes important [X — length of component) Abbreviations used: VHF very high frequency UHF ultra high frequency SHF super high frequency EHF extremely high frequency Table 1 Band Designations according to "VO Funk" (Radio Transmission Association) according * Coaxial connectors with operating frequencies within these ranges will be dealt with here. HUBER+SUHNER CONNECTOR GUIDE

カタログの10ページ目を開く
RF - Guide - 11

INTRODUCTION TO BASIC RF THEORY CONSTRUCTION AND FUNCTION OF RF LINES Coaxial lines represent the most efficient method of transmitting signals from a source (Figure 3) via a RF line to a termination. The most commonly used method is that of cable assemblies, where the distance between the source and the termination is the assembly length. Direction of Propagation Source (load) Connector Pairs Figure 3 Direction of propagation along a RF line The most important factor in connector selection is the RF cable chosen, as this usually will set the minimum connector specifications such as...

カタログの11ページ目を開く
RF - Guide - 12

INTRODUCTION TO BASIC RF THEORY Outer Conductor Dielectric (Insulator) Inner Conductor (Centre Contact) Figure 5 Due to the concentric inner and outer conductor construction, the coaxial line is well protected against outside influences. The signals will be transmitted in TEM-mode (Transversal Electric and Magnetic field) until the upper frequency limit, the so-called cut-off frequency (refer to Chapter 1.2.6 on page 18), is reached. The mechanical construction of the RF line determines this point. Basically, the smaller the mechanical dimensions the higher the frequencies. No fields exist...

カタログの12ページ目を開く

HUBER+SUHNER/フーバーのすべてのカタログと技術パンフレット

  1. Antennas edition 2020

    109 ページ

  2. Automotive products

    72 ページ

  3. WHITE PAPER

    7 ページ

  4. Data center solutions

    238 ページ

  5. Connected Mobility

    24 ページ

  6. RF cables

    72 ページ

  7. Fiber Optic Cables

    178 ページ

  8. Antennas edition 2019

    105 ページ

  9. FO components

    11 ページ

  10. Lightning protection

    206 ページ

  11. RF components

    44 ページ

  12. Space

    140 ページ

  13. Railway products

    208 ページ

  14. Aviation

    28 ページ

  15. Network-Cubes

    8 ページ

  16. Defense

    146 ページ

  17. FO LISA

    202 ページ

  18. Airfield Lighting

    4 ページ

  19. Wires & Cables

    156 ページ

  20. Milcat 7

    2 ページ

  21. VITA 67

    2 ページ

  22. Microbend L

    2 ページ

  23. FO Cabling Systems

    64 ページ

  24. FO Cables

    160 ページ

  25. Automotive products

    68 ページ

  26. Air traffic control

    28 ページ

  27. RADOX® Milcat 7

    2 ページ

  28. Resistive components

    36 ページ

  29. Lightning protection

    200 ページ

  30. Aviation

    28 ページ

  31. Train to ground

    16 ページ

  32. Railway products

    200 ページ

  33. Railway connectivity

    24 ページ

  34. Passive Components

    36 ページ

  35. FO tools equipment

    10 ページ

  36. FO LC Portfolio

    24 ページ

  37. DC Segment Finance

    12 ページ

  38. Cabling Systems

    64 ページ

  39. RF Connectors

    478 ページ

  40. Railway Products

    156 ページ

  41. QMA - Connectors

    16 ページ

  42. MMPX - Connectors

    24 ページ

  43. Fiber Optic - CLIK!

    12 ページ

  44. Space-SUCOFLEX TVAC

    12 ページ

  45. Space-SUCOFLEX 300

    24 ページ

  46. Multiport Solutions

    12 ページ

  47. Medical

    20 ページ

  48. Automation Machinery

    20 ページ

  49. Rail CBTC

    12 ページ