Proportional directional spool valve type EDL Product documentation Series connection Operating pressure pmax: Flow rate Vmax:
カタログの1ページ目を開く
© by HAWE Hydraulik SE. The reproduction and distribution of this document as well as the use and communication of its contents to others without explicit authorisation is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of patent or utility model applications. Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names and trademarks, usage is subject to legal provisions. HAWE Hydraulik respects these legal provisions in all cases. Printing date / document...
カタログの2ページ目を開く
Overview of proportional directional spool valve type EDL Proportional directional spool valves are a type of directional valve. They control the direction of movement and the velocity of individual or multiple hydraulic consumers actuated simultaneously. Control is independent of the load and continuous. The directional spool valve type EDL with series connection is actuated directly. The ow rates for the individual consumers can be individually adjusted. The proportional directional spool valve can be exibly adapted to different control tasks by means of additional functions in the...
カタログの4ページ目を開く
Available versions, main data 2.1 Order coding, overview Order coding example: PSV 3X End plates Ancillary blocks Actuation types Shuttle valve LS pressure limitation Flow rates Table 12 Ancillary blocks (selection) Table 12a Intermediate plates (selection) Table 10 Actuation types Table 9 Shuttle valve Table 8 LS pressure limitation Table 7 Maximum ow rates P d A(B) Table 7a Combination of ow rates Circuit symbols Inow controller Table 11 Solenoid voltage and solenoid version Table 6 Circuit symbols Table 5 Inow controller Directional valve, basic block Table 4 Basic block Size...
カタログの5ページ目を開く
2.2 Connection blocks and end plates There are the following basic variants of connection blocks: ■ ■ Connection blocks with integrated 3-way controller when using a constant pump system (open centre) – type PSL Connection blocks for use with variable pump systems (closed centre), constant pressure systems or for parallel oil supply of multiple physically separate directional spool valve banks in the second and all further valve blocks – type PSV Adapter plates for combining proportional directional spool valves type PSL and PSV, size 3 and 5 Order coding of a single connection block...
カタログの6ページ目を開く
Table 2 Additional elements (For notes and explanation, see Chapter 6, "Other information" ("On connection blocks")) Additional elements only suitable where variable pumps are used (limitation of the control oil ow). Coding Standard, without additional element Orice # 0.4 mm, 0.5 mm, 0.6 mm, 0.7 mm or 0.8 mm in the LS gallery (for control oil limitation)
カタログの7ページ目を開く
2.2.2 End plates Order coding example: PSV 3 X - 2 Table 3 End plates Coding Circuit symbol End plate without additional function, not in combination with valve sections SL2, SL3 or SL5 • Can only be used with max. three sections • Only in conjunction with shuttle valve, coding W 3, Table 9 in last valve section Operating pressure max = 250 bar! With control oil return line T external to tank Like E 1, with additional port Y for connection to the LS outlet of another, separately arranged PSV spool block Like E 1, however control oil return line is internal, maximum return pressure of 10...
カタログの8ページ目を開く
2.3 Valve section 2.3.1 Directional valve Order coding example: PSV 31/D250 - 2 - Ancillary blocks Actuation types LS pressure limitation Flow rates Table 10 Actuation types Table 8 LS pressure limitation Table 7 Maximum ow rates P d A(B) Table 7a Combination of ow rates Circuit symbols Inow controller Table 12 Ancillary blocks (selection) Table 12a Intermediate plates (selection) Table 6 Circuit symbols Table 5 Inow controller Directional valve, basic block Order coding of the single valve section (examples): Table 4 Basic block Valve section Valve spool (single) The size specification...
カタログの9ページ目を開く
Table 4 Basic block Coding Complete valve section with an ancillary block in accordance with Table 12 D 7700-2 Circuit symbol With respect to main ow and actuation, the circuit symbols are neutral and must be supplemented by the corresponding circuit symbols given according to Table 6 to 10, Chapter 6, see also examples in Table 10 4/3-way directional spool valve with inow controller Example: - DA 7 H40/40/E/2 (-DT 12) 4/3-way directional spool valve with inow controller and LS pressure limitation Example: - DA 2 L25/16 C 200 /E/2 (- X 24) 1 Ancillary block and intermediate block acc. to...
カタログの10ページ目を開く
Table 6 Circuit symbols L Table 7 Maximum ow rates P d A(B) in accordance with coding Coding for spool valve acc. to Table 6 Coding for ow rate QA, B (lpm) at consumer ports A and B 3 The specied nominal ow rates correspond to the set values for E actuation. For EI actuation, the max. ow rates can be higher. The maximum reux ow rate must not exceed 80 lpm. The ow rates for the consumer ports A and B can be selected in accordance with Table 7a, e.g. 40/25, 16/16. This enables optimal adaptation to the respective consumer while exploiting the full functional lift. In addition, there...
カタログの11ページ目を開く
Table 8 LS pressure limitation Coding Circuit symbol Without protection Joint LS pressure limitation for A and B with pressure specification and load pressure, signal output G 1/8 (BSPP), only in conjunction with solenoid version coding AMP.. and DT.. (Table 11) Order coding example: DA 2 L 25/16 Shuttle valve Table 9 Shuttle valve Table 9 Shuttle valve Coding Shuttle valve in LS gallery Without shuttle valve, e.g. in last valve section for combination with end plate coding E 0 Circuit symbol
カタログの12ページ目を開く
Table 10 Actuation types Coding Circuit symbol Electrical actuation with stroke limitation Electrical actuation with manual override Electrical actuation with manual override, A-side only Electrical actuation with manual override, B-side only For reference values for start of ow at A or B (= min.) up to max. usable volume ow in accordance with Table 7, see Chapter 3.2, "Characteristics" The solenoid voltage and solenoid version are dened at the end of the type designation and applies to all solenoids in the valve bank, see Table 11 Table 11 Solenoid voltage and solenoid version Coding...
カタログの13ページ目を開くHAWE Hydraulik SEのすべてのカタログと技術パンフレット
-
VR
15 ページ
-
BVE
54 ページ
-
SLC
17 ページ
-
BNG
25 ページ
-
BA
45 ページ
-
VB
88 ページ
-
VP
35 ページ
-
VH
6 ページ
-
SL1
15 ページ
-
NBVP 16
68 ページ
-
EM
41 ページ
-
CR
4 ページ
-
BVG 1
13 ページ
-
SMD
15 ページ
-
PSLF
60 ページ
-
PS
20 ページ
-
HSF
4 ページ
-
SWS
12 ページ
-
NSWP 2
8 ページ
-
SG
42 ページ
-
K61N
17 ページ
-
K60N
19 ページ
-
V30D
60 ページ
-
V80M
30 ページ
-
V30E
51 ページ
-
RZ
12 ページ
-
C40V
47 ページ
-
HR 080
17 ページ
-
HICON
14 ページ
-
INKA
35 ページ
-
FXU
35 ページ
-
ROLV
23 ページ
-
V60N
71 ページ
-
Product catalogue
299 ページ