
グループ: Ingersoll Rand
カタログの抜粋

Pressure on Demand Pneumatic and Hydraulic Driven Gas Boosters
カタログの1ページ目を開く
Why Use a Haskel Gas Booster Haske pneumatic and hydraulic driven gas boosters offer a flexible and efficient source for delivering high pressure gases. Oxygen or High Purity Cleaning: Haskel boosters are noted for their cleanliness and can handle pure gases such as oxygen without risk of any contamination. (Special cleaning required – advise factory.) Haskel’s oxygen cleaned products are certified per Mil Spec 1330. Refer to the Knowledge Library Link on the Haskel website, www.haskel.com, for the Oxygen Usage - Best Practice Guide. Multi-Staging Capability: For higher flow rates and...
カタログの2ページ目を開く
Introduction to Pneumatic Driven Gas Boosters Theory of Operation Haskel Gas Boosters consist of a large area reciprocating air drive piston directly coupled by a connecting rod to a small area gas piston. The gas piston operates in a high pressure gas barrel section. Each gas barrel end cap contains high pressure inlet and outlet check valves. Varying applications require many different booster and horse power (HP) combinations. Haskel can assist with HP and Cooling requirements and provide circuitry assistance on the following issues: PID Control review and advisement, electrical control,...
カタログの3ページ目を開く
Pneumatic Driven Gas Booster Configurations Single acting, single stage boosters are the smallest and lightest with pressures to 39,000 psi. Double acting, single stage provides twice the delivery of a single acting single stage booster. Two stage models are used for high gas compression ratios. Model AG Single Stage, Single Acting, Flow Thru Piston Model AG Single Stage, Single Acting Model AGD Single Stage, Double Acting, Cooling Fins Model AGD-4 (only) Single Stage, Double Acting, Cooling Jacket Model AGD Single Stage, Double Acting, Cooling Jackets Multi stage - Two boosters. More than...
カタログの4ページ目を開く
Selecting a Pneumatic Driven Gas Booster means of boosting pressure for testing or small components and similar applications where volume is small and efficiency is not important. Control of maximum outlet pressure is accomplished with the use of an air drive pressure regulator. Maximum outlet pressure is drive area ratio multiplied by air pressure. Air driven gas boosters have seven significant operating parameters that determine their selection for any application. These are as follows: 1. Maximum discharge pressure? 2. Flowrate a. Is it constant? i. What is flowrate required? b. Is it...
カタログの5ページ目を開く
Model Selection Chart Model Number Maximum Rated Gas Supply LEGEND: Ps = Gas Supply Pressure, Pa = Drive Pressure, Po = Outlet Pressure Maximum Rated Gas Outlet Static Piston Outlet Stall Displacement Pressure Per Cycle Formula Single Acting Single Stage Model AG Inlet Port 3/4” NPT Outlet Port 1/2” NPT Inlet Port: 3/8” NPT Outlet Port: 3/8” NPT 2 ea./ inlet & outlet Double Acting Single Stage Model AGD Interchangeable 3-3/8”SAE or 1/4”- H/P (BuTech) Both Ports Inlet Port: 3/8” NPT Outlet Port: 3/8” NPT Interchangeable 3-3/8”SAE or 1/4”-H/P both Ports. 2 ea. inlet & outlet Interchangeable...
カタログの6ページ目を開く
Model Number Maximum Rated Gas Supply PSIG Maximum Rated Gas Outlet Inert Gas Static Outlet Piston Stall Pressure Displacement Formula Per Cycle Interchangeable 3/8”SAE or 1/4” H/P (BuTech) Both Ports Interchangeable 3-3/8”SAE or 1/4”- H/P (BuTech) Both Ports Interchangeable 3-3/8”SAE or 1/4”- H/P (BuTech) Both Ports Interchangeable 3/8”SAE or 1/4” H/P (BuTech) Both Ports Interchangeable 3/8”SAE or 1/4” H/P (BuTech) Both Ports Interchangeable 3/8”SAE or 1/4” H/P (BuTech) Both Ports Interchangeable 3/8”SAE or 1/4” H/P (BuTech) Both Ports Interchangeable 3/8”SAE or 1/4” H/P (BuTech) Both...
カタログの7ページ目を開く
Sample Gas Booster Flow Rate Performance (SCFM) Flow and Pressure Performance: Sample performance shown below is used for general reference only; consult Haskel Technical Sales or your Haskel Representative for specific performance information. Cubic Meters Per Minute = SCFM x 0.0283 Catalog Number AG-4 AG-7 AG-15 AG-30 AG-50 AG-62 AG-75 AG-102 AG-152 AG-233 AG-303 AGD-1.5 AGD-4 AGD-7 AGD-14 AGD-15 AGD-30 AGD-32 AGD-50 LEGEND Pa = Air Drive Pressure Ps = Gas Supply Pressure Qa = Air Drive Quantity Po = Gas Outlet Pressure Q = Gas Outlet Flow Rate
カタログの8ページ目を開く
Alternative Gas Booster and System Models Specialty Gas Booster Models Standard Model Number Oxygen Booster Model Number Hydrogen Booster Model Number Standard Model Number Oxygen Booster Model Number Inert Gas Booster System Models Hydrogen Booster Model Number Standard Model Number Standard System Model Number Oxygen System Model Number Standard Model Number Standard System Model Number Oxygen System Model Number
カタログの9ページ目を開く
Inert Gas Booster Systems Haskel’s ability to incorporate and interface electronic controls into systems provides precise compression and control of gases. Standard system components are: 1. Booster with External Pilot Modification to enable use of external components to start/stop the booster. 2. Adjustable Air Pilot Switch (inlet) – used to stop the booster when supply pressure falls to adjusted set point. 3. Adjustable Remoteset Air Pilot Switch (outlet) – used to stop the booster when outlet pressure reaches adjusted set point. 10 4. Pressure Gauge indicates outlet boosted pressure. 5....
カタログの10ページ目を開く
Mini Charging Booster Designed and Manufactured to achieve an affordable and effective gas transfer and charging unit. Standard configuration includes cylinder mounting bracket. ScubAmp Used by Dive Shops to boost medium pressure breathing air from storage air direct to dive tanks to reach maximum fill pressure rapidly. With the use of a ScubAmp, existing air compressor systems can stay within their 200-2500 psi normal operating range. TYPICAL FILL TIMES AIR DRIVE INLET PORT 1/2’’ FNPT (150 PSIG MAX) To Nominal Tank Size and Pressure From Pressure in Storage (After Equalizing in Dive Tank)...
カタログの11ページ目を開くHaskelのすべてのカタログと技術パンフレット
-
Subsea Valves
18 ページ
-
Hydrogen Valves
8 ページ
-
Pneumatic Liquid Pump
28 ページ
-
Refrigerant Pumps
2 ページ
-
Butech Oil Gas
12 ページ
-
Air Pressure Amplifiers
12 ページ
-
H-Drive Cut Sheets
2 ページ
-
Mini Charging Cart
2 ページ
-
Fire Fighting Safety
12 ページ
-
HGD-90
2 ページ
-
HGD-150
2 ページ
-
HGT-90/63
2 ページ
-
HGT-150/63
2 ページ
-
HGT-150/90
2 ページ
-
ScubAmp
2 ページ
-
Oxygen Boosters
2 ページ
-
Oil and Gas
6 ページ
-
Air Pressure Amplifers
12 ページ
-
H-Drive
4 ページ
-
Oil & Gas
6 ページ
-
Air Pressure Amplifier
12 ページ
-
Liquid Pumps
28 ページ
-
BuTech Subsea Valves
32 ページ
カタログアーカイブ
-
Airline Industry
4 ページ