カタログの抜粋

GRUNDFOS DATA BOOKLET UPM3, UPM3 HYBRID, UPM3 AUTO, UPM3 AUTO L, UPM3 FLEX AS, UPM3 FLEX AC, UPM3 SOLAR, UPM3 DHW, UPM3 K 1 x 230 V, 50 Hz
カタログの1ページ目を開く
ErP, Ecodesign regulation in brief 8 4. UPM external control mode and signals 14 5. UPM3 HYBRID control modes, user interface and settings 17 User interface control modes for UPM3 HYBRID variants 20 Exploded view and sectional view 28 12. Performance curves, technical data 48 Drinking water approvals 91 UPM3 OEM circulators - Grundfos Product Chemical Compliance declaration concerning the non-use of certain chemical substances 91
カタログの2ページ目を開く
Introduction (only externally controlled PWM A/C profile) UPM3 - HYBRID variants UPM3 FLEX AC 7.5 m UPM3 FLEX AC 7 m UPM3 FLEX AC 5 m UPM3 FLEX AS 7.5 m UPM3 FLEX AS 7 m UPM3 FLEX AS 5 m UPM3 SOLAR 14.5 m UPM3 SOLAR 10.5 m UPM3 SOLAR 7.5 UPM3 DHW 7"m UPM3 DHW 5"m UPM3 DHW 2m UPM3 AUTO L 7"m UPM3 AUTO L 5"m UPM3 AUTO 7"m UPM3 AUTO 5"m UPM3 HYBRID 7 m UPM3 HYBRID 5 m (only externally controlled PWM A/C profile) (MAX or externally controlled PWM A profile) (CC or externally controlled PWM C profile) (MAX or externally controlled PWM A profile) (only internally controlled PP/CP/CC) (only...
カタログの3ページ目を開く
Applications In a modern heating, cooling and domestic hot water supply system there are different circuits in which UPM3 circulator pumps in different versions can be placed. A differentiation must be made between the heating (or cooling) production and the distribution. On the production side there are some applications where circulator pumps are used in primary or internal circuits e.g. for geothermal or solar thermal brine circuits. The distribution side is often split into two circuits - a primary and a secondary circuit - in order to keep the flow and temperature independent from each...
カタログの4ページ目を開く
Gas or oil-fired space and combination heaters Most of the installed systems for space and water heating in building services are still using fossil fuels such as natural gas or mineral oil, although the use of gas and liquid fuels out of biomass is increasing. Heaters with higher water content, such as floorstanding boilers, are heated independent of the actual flow. Heaters as wall-mounted boilers are only fired when there is a minimum flow through the primary heat exchanger. In a combi-boiler, the circulator pump supplies both the heating system and the hot water supply. More and more of...
カタログの5ページ目を開く
Micro/Mini combined heat and power cogeneration Cogeneration of heat and power (CHP) can be divided into combustion engines, stirling engines and fuel cells. Dosing and circulator pumps with customised specification are often installed inside the fuel cell process unit. Used secondary circulators are not that different from boiler applications. However, vibrations, liquid temperature and ambient temperature can be relatively high. Often a constant flow is required, therefore a buffer tank is an advantage. Thermal solar system Solar collectors convert sunlight into heat that can be used for...
カタログの6ページ目を開く
This circulator pump range is designed for integration in boilers and other heating appliances with remote control of the speed, corresponding to low-voltage PWM signal input. One-pipe heating system Two-pipe heating system Underfloor heating system This circulator pump range with user interface is designed for several purposes: • The internal-controlled variant can be used in heating appliances as stand-alone or replacement pump, for example in heating kits. • The remote-controlled variant can be integrated in boilers and other heating appliances where the speed is changed, corresponding...
カタログの7ページ目を開く
2. Features and benefits Features • Speed-controlled, high-efficiency circulator fitted with electronically commutated motor (ECM) with permanent-magnet rotor and frequency converter. • Either externally controlled by digital pulse-width modulation (PWM) low-voltage signal or internally controlled in constant pressure, proportional pressure or constant speed mode defined by the means of a smart user interface or factory presetting. • Third generation of the first boiler-integrated, variable-speed ECM circulators which combines both validated and newly developed components and concepts. •...
カタログの8ページ目を開く
UPM3 Standard UPM3 K K-Version Control variant HYBRID PWM A/C, PP, CP, CC, AA Nominal diameter Maximum head Pump housing GGES2 Cast iron CED, end suction UPM3 GGMBP3 Cast iron CED, GGMBP3 UPM3 GGBP3 Cast iron CED, GGBP3 UPM3 Customer code Control signal connector Minimum speed External control signals 1 and 2 A PWM Profile A, heating C PWM Profile C, solar CRUNDFOS^ Features and benefits
カタログの9ページ目を開く
Features and benefits Nameplate options GFNJX © 1 EEIS 0.XX - Part X PL.avg. < XXW ® ) XXXV~XX/XXHz IPXXX TFXXX @ @ 12 © Min. XX°C H) > PN:XXXXXXXX PC:XXXXXXX 17 SN:XXXXXXXX ) Made in XXXXXX Pos. Terminal box side 1 Speed 2 Rated current, I1/1 [A] at maximum and minimum 3 Input power P1 [W] at maximum and minimum 4 Maximum system pressure [MPa] 5 CE mark 8 Energy index with indication of measurement standard 9 Average power input PL,avg (Ecodesign regulation) 10 Power supply voltage AC ~1 Voltage [V] 14 Temperature class 15 Minimum medium temperature (only cold water...
カタログの10ページ目を開く
Pump curves: Performance range Performance range UPM3, cast iron pump housing Pump curves: Fig. 10 Performance range UPM3 SOLAR, cast iron pump housing
カタログの11ページ目を開く
Performance range Pump type Port-to-port length [mm] Control signal Connection pipe thread Internally controlled PP/CP/CC Digital low voltage PWM bidirectional
カタログの12ページ目を開く
Pump type Port-to-port length Connection pipe thread Control signal Internally controlled PP/CP/CC Digital low voltage PWM bidirectional Other versions or housings with different dimensions, materials, design or functionality are available on request. Please contact your Grundfos HVAC OEM KAM. Performance range GRUNDFOS^ 13
カタログの13ページ目を開く
4 UPM external control mode and signals 4. UPM external control mode and signals Control principles The UPM3 and UPM3 FLEX circulators are controlled via a digital low-voltage pulse-width modulation (PWM) signal which means that the speed of rotation depends on the input signal. UPM3 HYBRID circulators are controlled either internally or externally can be set to either internal or externally controlled. The speed changes as a function of the input profile. These communication signals are standardized in the VDMA Einheitsblatt 24244 "Wet runner circulating pumps Specification of PWM control...
カタログの14ページ目を開くGRUNDFOS/グルンドフォスのすべてのカタログと技術パンフレット
-
GRUNDFOS ALPHA2
20 ページ
-
Grundfos ALPHA1
24 ページ
-
ALPHA1 L
2 ページ
-
DME
2 ページ
-
GRUNDFOS UPM3
11 ページ
-
Vaccuperm VGA and VGB
28 ページ
-
PURIFY YOUR BUSINESS
9 ページ
-
PUST 1700 RANGE
3 ページ
-
Grundfos LiqTec
2 ページ
-
CRN Air-Cooled Top
2 ページ
-
CRN MAGdrive
2 ページ
-
GRUNDFOS CRE
2 ページ
-
Customised solutions
21 ページ
-
TPE3
7 ページ
-
Grundfosliterature
5 ページ
-
CIM/CIU
3 ページ
-
BMS
5 ページ
-
BM
2 ページ
-
BACMON
16 ページ
-
AQtap
7 ページ
-
ALPHA2 L OEM
19 ページ
-
E-Solutions and GRM
2 ページ
-
CRE GRUNDFOS
2 ページ
-
MTA
3 ページ
-
Unilift CC
2 ページ
-
DMH -Product leaflet
2 ページ
-
ALPHA1
2 ページ
-
AMD-AMG-AFG
3 ページ
-
S - product brochure
16 ページ
-
CRT for seawater
2 ページ
-
CRT for industry
2 ページ
-
HS
5 ページ
-
SQ
3 ページ
-
SP ENGINEERING MANUAL
47 ページ
-
MAGNA/UPE
12 ページ
-
Pressure Manager
5 ページ
-
Selcoperm SES
20 ページ
-
Conex DIS-G
2 ページ
-
Conex DIS-C
2 ページ
-
Sololift2
9 ページ
-
VGA and VGB
28 ページ
-
Oxiperm Pro
8 ページ
-
DMX
18 ページ
-
DMH
18 ページ
-
MP 204
3 ページ
-
TP/TPE
5 ページ
-
SP Product
7 ページ
-
S-Tube
4 ページ
-
SB & SBA
8 ページ
-
HOME AND GARDEN
52 ページ
-
Product Brochure
5 ページ
-
Multilift
21 ページ
-
NB, NBG, NK, NKG
3 ページ
-
KPL and KWM
3 ページ
-
Grundfos GO
3 ページ
-
DW
12 ページ
-
DIP
16 ページ
-
GRUNDFOS CONTROL MPC
5 ページ
-
NEW ALPHA2
7 ページ
-
Wastewater products
10 ページ
-
GRUNDFOS DWK
3 ページ
-
GRUNDFOS DPK range
3 ページ
-
GRUNDFOS DP
5 ページ
-
DIT-L, DIT-M Photometer
16 ページ
-
DME, DMS, DDI
14 ページ
-
Diffuser
3 ページ
-
CUE E-SOLUTIONS
12 ページ
-
CR monitor
8 ページ
-
CR ? Innovation inside
20 ページ
-
Control MPC
4 ページ
-
CMV
8 ページ
-
CM, CME Booster
52 ページ
-
CIM / CIU
3 ページ
-
BMP
9 ページ
カタログアーカイブ
-
A WIDE RANGE 2019
60 ページ
-
A WIDE RANGE 2015
60 ページ