Safe-NET Network Transformer
1 / 8ページ

{{requestButtons}}

カタログの抜粋

Safe-NET Network Transformer - 1

Safe-NET Network Transformer Safely and reliably supply power to secondary grid systems Utilities provide safe and reliable electrical service to their end customers. In large metropolitan areas with densely populated cities, utilities provide this service over secondary network distribution systems. These network systems are largely underground, therefore the network transformers that support these systems are a vital and critical part of the electrical infrastructure. GE's Safe-NET network transformers are the safest transformers available in the industry for secondary network applications. Safe-NET network transformers are designed to supply power to the network bus and are capable of handling significant short-term overload conditions in this application. GE's exclusive transformer tank design features patented tank technology that minimizes the danger from a transformer rupture event, mitigating its impact to adjacent assets and public safety. Key Benefits • Increased Public Safety Patented tank design significantly reduces risk to the public and property that may be in close proximity to the transformer location when a high-energy event occurs • Increased Operational Safety and Performance Tank design is capable of withstanding in excess of 11 mega joules of energy, exceeding the pressure requirements laid out in the IEEE C57.12.40 standard • Validated Risk Mitigation and Peace of Mind Independent, 3rd party validation by KEMA of tank design and response to high energy events • Exceptional Product Durability and Reliability The zinc epoxy primer and black epoxy top-coat paint utilized is superior to any other paint solution used today, passing 10,000-hour salt-spray certification tests • Eco-friendly with Low Carbon Footprint Available high flash point vegetable-based insulating oil reduces environmental impact Applications GE's Safe-NET Network Transformers are used in applications where safety, reliability, service continuity and minimum maintenance are the key objectives, including: • Underground metropolitan vault applications • Office towers, skyscrapers • Government, commercial, institutional and • Vault applications with occasional/continuous industrial facilities submersion GE's Network Transformers can also be applied to non-network applications where superior sealing and corrosion protection are of primary importance. These non-network applications also include intertie [step] transformers for interconnecting two different voltage systems. Exclusive Tank Design • Patented tank technology provides a safe and controlled failure-mode during high energy events • Exclusive transformer tank design and patented tank technology minimizes the danger from an "end-of-life" event resulting from a high-energy fault • Best in class corrosion resistant paint minimizes maintenance over long haul and increases life cycle of transformer Exceeds Industry Standards • The Safe-NET tank design exceeds the tank pressure requirements laid out in the ANSI®/ IEEE® C57.12.40 standard • Patented tank design can contain most high energy events • Best in class product lifecycle including an installed base with 85+ years of service 3rd Party Validated • GE's units are capable of withstanding in excess of 11MJ of energy, confirmed by KEMA® testing • Tested and certified to the highest North American standard for ground-level seismic levels, CBC-2013 section 1705A.12 and IBC 2012 section 1705.12, tested to (an acceleration value of) SDS = 2.5 • Superior zinc epoxy primer and black epoxy top coat paint with 10,000 hour salt-spray certification

カタログの1ページ目を開く
Safe-NET Network Transformer - 2

Low Voltage Secondary Network Overview Since the 1920’s, the low voltage secondary network has been an effective method of serving dense loads like office buildings and downtown areas. The basic design of the network system ensures high reliability and dependable power quality. The network system’s reliability comes from having multiple sources. The grid network in the diagram below shows that the network system is fed by multiple transformers with multiple sources back at the substation. This means that the loss of any single transformer or line will not have an effect on the load served...

カタログの2ページ目を開く
Safe-NET Network Transformer - 3

Network Transformer Application Overview The transformers that are used in these low voltage secondary networks are referred to as network transformers. Space limitations in urban environments result in the network transformers being installed in various applications such as indoor and outdoor vaults as well as inside buildings. All of these applications will typically have these network transformers in close proximity to pedestrian and other traffic. The image to the right represents a typical application for a network transformer, where it is placed in an underground vault under a...

カタログの3ページ目を開く
Safe-NET Network Transformer - 4

GE’s Network Transformers High Fault Energy Tank Design Challenge Arcing, corrosion and overloading are the three key drivers for end-of-life tank events in network transformers. Given the network transformers placement in underground vaults, which very often are below sidewalks, service events in the field pose a risk of injury to individuals in close proximity as well as additional asset damage and power outages. Traditional network transformers do not have the same capacity to contain high energy events which can often cause undesired collateral damage resulting from an uncontrolled tank...

カタログの4ページ目を開く
Safe-NET Network Transformer - 5

Network Transformer Features Switch-box with cover removed (primary switch is exposed) Primary switch contacts and rotor Switch-box liquid-level gauge and filling provision Main tank thermometer Main tank liquid level gauge

カタログの5ページ目を開く
Safe-NET Network Transformer - 6

STANDARD OFFERING OPTIONAL OFFERING Power Ratings 300kVA through 2500kVA (three-phase only) • Up to 3000kVA for step-down/intertie designs • Special kVA ratings to maximize kVA/in3 in the vault Voltage Ratings • Primary Voltages from 2.4kV through 34.5kV • Dual Voltage (series multiple) primary • Primary taps per C57.12.40 • Special Primary taps • Secondary Voltages from 208GrdY/120 to 480GrdY/277 • Secondary Voltages up to 4.33kV (60kV BIL rating) BIL Ratings • Primary BIL ratings 60kV to 200kV BIL Non-standard BIL ratings • Secondary BIL rating of 30kV BIL Thermal...

カタログの6ページ目を開く

GE Grid Solutionsのすべてのカタログと技術パンフレット

  1. Kelman TRANSFIX

    2 ページ

  2. Kelman MINITRANS

    2 ページ

  3. MIG

    3 ページ

  4. DTR

    4 ページ

  5. SPM

    8 ページ

  6. TOV

    3 ページ

  7. MDS SD Series

    4 ページ

  8. MIC

    2 ページ

  9. Multilin F60

    9 ページ

  10. Model PT6-2-125

    2 ページ

  11. Model PT6-1-125

    2 ページ

  12. Model 3PT3-60

    2 ページ

  13. MIG II

    8 ページ

  14. Model JVW-110C

    2 ページ

  15. Model JVW-5AC-1

    2 ページ

  16. Model JVW-5C

    2 ページ

  17. Multilin T60

    9 ページ

  18. Multilin 489

    9 ページ

  19. Multilin™ D25

    8 ページ

  20. Multilin D485

    1 ページ

  21. Multilin P485

    1 ページ

  22. MultiNet

    3 ページ

  23. iNET-II

    4 ページ

  24. MDS™ iNET 300

    2 ページ

  25. MDS iNET 900®

    2 ページ

  26. Multilin™ PQM II

    8 ページ

  27. Multilin L90

    10 ページ

  28. COSI

    2 ページ

  29. Reason DR60

    4 ページ

  30. Multilin 850

    4 ページ

  31. G650

    8 ページ

  32. Hydran M2

    2 ページ

  33. TN1U

    4 ページ

  34. Multilin™ MM200

    8 ページ

  35. Multilin™ MM300

    8 ページ

  36. Multilin 339

    16 ページ

  37. Multilin 469

    10 ページ

  38. Multilin A60

    6 ページ

  39. Multilin 350

    16 ページ

  40. Multilin F650

    12 ページ

  41. Multilin 750/760

    10 ページ

  42. F35

    8 ページ

  43. 345

    12 ページ

  44. 745

    8 ページ

  45. Multilin G30

    9 ページ

  46. Air-Core Reactors

    8 ページ

  47. Multilin UR & URPlus

    18 ページ

  48. Multilin C30

    6 ページ

  49. Voltage Regulators

    16 ページ

  50. g3 Technology

    2 ページ

  51. Rectifier

    4 ページ

  52. RMIO

    2 ページ

  53. MiCOM Agile P54A/B

    2 ページ

  54. MultiSync™ 100

    6 ページ

  55. Multilin G60

    9 ページ

  56. Multilin D400

    12 ページ

  57. GL 107X

    2 ページ

  58. Disconnectors

    12 ページ

  59. CGVB-05

    2 ページ

  60. KOTEF

    4 ページ

  61. FK

    4 ページ

  62. B65

    4 ページ

  63. COSI-RogoFlex

    2 ページ

  64. MiCOM Agile P24x

    8 ページ

  65. Power Transformers

    8 ページ

  66. smorb

    3 ページ

  67. MIF II

    8 ページ

  68. SR family

    2 ページ

  69. 735/737

    4 ページ

  70. hid

    2 ページ

  71. dtp

    5 ページ

  72. IEC Oil Filled & SF

    12 ページ

  73. M60

    8 ページ