カタログの抜粋

Enhanced DGA monitoring for transformers Transformers are key and expensive components of the electrical grid and knowledge of their health condition is essential to having a reliable network. When a transformer’s insulation system is overstressed, gases are produced that dissolve in the oil. Dissolved Gas-in-oil Analysis (DGA) is recognized as the best indicator of developing faults. Asset Supervision • Easy to permanently install on a single transformer oil valve. No extra piping or pump required. Optional inputs for other sensors The Hydran™ M2 is a continuous on-line dissolved gas and moisture in oil monitoring device that alerts personnel of developing fault conditions in their transformer. It provides key monitoring information and minimizes the risk of an unplanned outage. • Choice of gas sensor: "Hydrogen only" or "Composite gas" which responds 100% to Hydrogen (general fault gas) and is also sensitive to Carbon Monoxide (paper) Acetylene (arcing) and Ethylene (oil) Through the connection of additional sensors (for example top and bottom tank oil temperature, transformer load or ambient temperature), additional information can be captured and used to correlate with DGA and moisture values for a more in-depth analysis of the transformer’s condition. • Moisture sensor measures water in the oil, a result of insulating paper degradation (produces CO + water) or leaking gaskets This wealth of data can, not only be transmitted raw using the M2’s wide range of communication options but can also be converted into useful information through the on-board calculation of IEEE® standard’s based transformer mathematical models to provide further condition information. Configurable Alarms Key Benefits • Continually measures dissolved fault gases and moisture in oil for early identifications of potential issues before they become critical transformer failures • Choice of gas sensor: traditional "Composite gas" or more basic "Hydrogen only" • Built-in calculation of transformer models based on IEEE standard (for mineral oil only) • Wide range of communication options and protocols simplifying integration into SCADA or DCS • Third generation of this proven design, with very large global installed base • Supports new lower flammability ester based oils as well as mineral transformer insulation oils Applications Power Utilities • All-in-one solution for important medium size transformers • Focuses and prioritizes asset replacement strategy Industrial Plants • Reduces the risk of process interruption due to power failure • Minimizes costly production downtime • An alarm is raised when an abnormal level of fault gas or moisture is detected. Two alarm levels (one for Alert and one for Alarm) can be set to show increasing severity • Alarms can also be set on values from optional analogue input cards or from optional calculated transformer models • Automatic self-test every 15 days will trigger service alarm if it detects a fault, including power failure, oil valve closed, faulty sensor Mark III Improvements • Completely overhauled with improved sensor durability, new electronic boards and power supply to make it RoHS compliant while increasing device reliability and capabilities • Suitable for transformers using mineral insulating oil but now also ester based oils (natural or synthetic) • Compatibility with GE’s acclaimed Perception™ softwa
カタログの1ページ目を開く
Transformer Models Hydran M2 equipped with 4 analog input modules The Hydran M2 offers transformer mathematical models for mineral oil based on IEEE standards and correlated with field experience. They use inputs from the available sensors and transform the received data into useful real time information to further understand the overall health of the transformer. Ambient temperature Possible models output examples: • • • • • • • Estimated winding hot spot temperature Moisture level in paper Moisture bubbling temperature Insulation ageing Overloading capacity Cooling efficiency OLTC...
カタログの2ページ目を開くGE Grid Solutionsのすべてのカタログと技術パンフレット
-
Kelman TRANSFIX
2 ページ
-
Kelman MINITRANS
2 ページ
-
MIG
3 ページ
-
DTR
4 ページ
-
SPM
8 ページ
-
TOV
3 ページ
-
MDS SD Series
4 ページ
-
MIC
2 ページ
-
Multilin F60
9 ページ
-
Model PT6-2-125
2 ページ
-
Model PT6-1-125
2 ページ
-
Model 3PT3-60
2 ページ
-
MIG II
8 ページ
-
Model JVW-110C
2 ページ
-
Model JVW-5AC-1
2 ページ
-
Model JVW-5C
2 ページ
-
Multilin T60
9 ページ
-
Multilin 489
9 ページ
-
Multilin™ D25
8 ページ
-
Multilin D485
1 ページ
-
Multilin P485
1 ページ
-
MultiNet
3 ページ
-
iNET-II
4 ページ
-
MDS™ iNET 300
2 ページ
-
MDS iNET 900®
2 ページ
-
Multilin™ PQM II
8 ページ
-
Multilin L90
10 ページ
-
COSI
2 ページ
-
Reason DR60
4 ページ
-
Multilin 850
4 ページ
-
G650
8 ページ
-
MultiLink ML3000 Series
12 ページ
-
TN1U
4 ページ
-
Multilin™ MM200
8 ページ
-
Multilin™ MM300
8 ページ
-
Multilin 339
16 ページ
-
Multilin 469
10 ページ
-
Multilin A60
6 ページ
-
Multilin 350
16 ページ
-
Multilin F650
12 ページ
-
Multilin 750/760
10 ページ
-
F35
8 ページ
-
345
12 ページ
-
745
8 ページ
-
Multilin G30
9 ページ
-
Air-Core Reactors
8 ページ
-
Multilin UR & URPlus
18 ページ
-
Multilin C30
6 ページ
-
Voltage Regulators
16 ページ
-
g3 Technology
2 ページ
-
Rectifier
4 ページ
-
RMIO
2 ページ
-
MiCOM Agile P54A/B
2 ページ
-
MultiSync™ 100
6 ページ
-
Multilin G60
9 ページ
-
Multilin D400
12 ページ
-
GL 107X
2 ページ
-
Disconnectors
12 ページ
-
CGVB-05
2 ページ
-
KOTEF
4 ページ
-
FK
4 ページ
-
B65
4 ページ
-
COSI-RogoFlex
2 ページ
-
Grid-GA-L3-COSI_CEVT
2 ページ
-
MiCOM Agile P24x
8 ページ
-
239 Motor Protection
8 ページ
-
Power Transformers
8 ページ
-
smorb
3 ページ
-
MIF II
8 ページ
-
SR family
2 ページ
-
735/737
4 ページ
-
hid
2 ページ
-
dtp
5 ページ
-
IEC Oil Filled & SF
12 ページ
-
Gas Insulated Switchgear
24 ページ
-
Multilin UR & UR Plus
18 ページ
-
M60
8 ページ