カタログの抜粋

g High Voltage Disconnect Switches Flexible design configurations from 72.5 - 800kV with Primary Pre-engineered solution set that digitizes XD|GE primary equipment and provides factory installed and configured protection, monitoring, diagnostics and communications.
カタログの1ページ目を開く
Technology Solutions for Global Utilities For over a century, utilities have relied on GE to deliver electrical products and services to meet their reliability and operational performance needs. GE is a leading provider of transmission and distribution solutions as well as grid automation systems that maximize utilities operational efficiencies and provides their customers with reliable power. With decades of experience, GE has brought reliable transmission and distribution products to utilities around the globe. GE has manufactured and partnered to install equipment in nearly 40 countries...
カタログの2ページ目を開く
Key Features • lexible design configurations from 126 – 800kV including F both horizontal and vertical configurations; center, side, double side, and V break designs • esigned for minimum but reliable clearance between D phases & vertical length • onductive parts are constructed of light-weight, strong C aluminum alloy • riving parts and balance spring are enclosed to minimize D environment exposure • ot dip galvanized process on all exposed iron and steel H parts provide excellent anti-corrosion capability • eight of porcelain and perpendicularity may be adjusted H via regulating bolts to...
カタログの3ページ目を開く
Overview Introduction XD|GE has more than 50 years of experience in disconnect switch research, development, and production. Advanced 3D design tools for simulation, assembly, and motion graphics help to improve the design quality and shorten the design and manufacturing cycles. The disconnectors are manufactured in a new 2,600 square meter workshop with an annual capacity exceeding 2,000 sets per year. Key Functions • solating - Provide a visible isolating point to ensure crew safety while I performing maintenance • witching– shifting equipment from one operation mode to another S...
カタログの4ページ目を開く
Product Portfolio Type Rated Voltage Rated Current Rated Peak Withstand Current Short Circuit withstand current/3s Type of Motor Operation Mechanism Motor Operating Mechanism CJ6 Series Motor Operating Mechanism The CJ6 series motor operation mechanism is easy to adjust, small in size, light weight, and compact. The housing is constructed from stainless steel riveted without welding resulting in an end product which is corrosion-proof as well as water and dust-proof. • Interlock units are able to meet multi-interlock functions at the same time. Secondary wiring board • he mechanisms are...
カタログの5ページ目を開く
GW4 Disconnect Switches Center Break Disconnect Switch GW4 series disconnect switches are structured in double columns for single pole, one break, and horizontal rotary opening. There are two columns in each phase. Supporting insulators at both ends are rotated horizontally by the operating mechanism in performing the open and close operations. The main conductive blade is mounted on the top of the supporting insulator. A mechanical interlock is mounted between the earthing switch and the main blade to ensure a correct operating sequence of the disconnect switch and earthing switch....
カタログの6ページ目を開く
B Height of Term Pad over Base (mm) 1258 1426 1640 1684 1780 2838 C Maximum Height of Disconnector over Base (mm) 1258 1426 1640 1684 1780 2838 D Support Insulator Distance (mm) E Insulator Height (BIL Related) (mm) 850 850 1200 1200 1200 2300 F (Minimum Isolating Distance) Min. Metal to Metal w/ Switch Open (mm) 710 830 1630 1630 1590 2250
カタログの7ページ目を開く
GW7 Disconnect Switches Double End Break Disconnect Switch GW7 series disconnect switches are structured in three columns for single pole, double breaks, and horizontal rotary openings. There are three columns in each phase. Supporting insulators at both ends are fixed while the middle one can be rotated horizontally by the operating mechanism in performing the open and close operations. The main conductive blade is mounted on the top of the middle supporting insulator, and the stationary contacts are on the top of the other two fixed contacts. A mechanical interlock is mounted between the...
カタログの8ページ目を開く
Disconnect Switch Operating Mechanism Ground Switch Operating Mechanism Nominal Ph-Ph Spacing (mm) 3000/3500 5000 User Define User Define B Height of Term Pad over Base (mm) 2850 3970 4770 5048 C Maximum Height of Disconnector over Base (mm) 3080 4240 5040 5811 D Support Insulator Distance (mm) E Insulator Height (BIL Related) (mm) 2300 3400 4000 4400 F (Minimum Isolating Distance) Min. Metal to Metal w/ Switch Open (mm) 1300 1800 2100 2370
カタログの9ページ目を開く
GW10 Disconnect Switches Vertical Pantograph Disconnect Switch The main blade of the GW10 series disconnect switch is a pantograph blade with an insulated single break in the vertical direction at the open position with minimum clearance between phases and vertical length. Key Benefits • rading ring is added at stationary contact to improve electric field G distribution and to effectively avoid corona. • Auxiliary contacts are added at both stationary contact and moving contact in order to avoid potential damages caused by electric arc during open and close operation. • Conductive parts are...
カタログの10ページ目を開く
Ground Switch Operating Mechanism Disconnect Switch Operating Mechanism A Nominal Ph-Ph Spacing (mm) User Define 3000 User Define User Define User Define B Height of Term Pad over Base (mm) 1527 2688 3715 4315 4715 C Maximum Height of Disconnector over Base (mm) 3700 6215 8317 9477 10877 D Support Insulator Distance (mm) 350 425 550 550 550 E Insulator Height (BIL Related) (mm) 1200 2300 3400 4000 4400 F (Minimum Isolating Distance) Min. Metal to Metal w/ Switch Open (mm) 2153 2550 3540 4100 5100 G Distance to Suspended Contact (mm) 3562 5955 7960 9120 10520 H Width of Disconnector (Open)...
カタログの11ページ目を開く
GW11 Disconnect Switches Horizontal Pantograph Disconnect Switch The main blade of the GW11 series disconnect switch is a pantograph blade with an insulated single break in the horizontal direction at the open position with minimum clearance between phases and vertical length. Key Benefits • rading ring is added at stationary contact to improve electric field G distribution and to effectively avoid corona. • Auxiliary contacts are added at both stationary contact and moving contact in order to avoid potential damages caused by electric arc during open and close operation. • Conductive parts...
カタログの12ページ目を開くGE Grid Solutionsのすべてのカタログと技術パンフレット
-
Kelman TRANSFIX
2 ページ
-
Kelman MINITRANS
2 ページ
-
MIG
3 ページ
-
DTR
4 ページ
-
SPM
8 ページ
-
TOV
3 ページ
-
MDS SD Series
4 ページ
-
MIC
2 ページ
-
Multilin F60
9 ページ
-
Model PT6-2-125
2 ページ
-
Model PT6-1-125
2 ページ
-
Model 3PT3-60
2 ページ
-
MIG II
8 ページ
-
Model JVW-110C
2 ページ
-
Model JVW-5AC-1
2 ページ
-
Model JVW-5C
2 ページ
-
Multilin T60
9 ページ
-
Multilin 489
9 ページ
-
Multilin™ D25
8 ページ
-
Multilin D485
1 ページ
-
Multilin P485
1 ページ
-
MultiNet
3 ページ
-
iNET-II
4 ページ
-
MDS™ iNET 300
2 ページ
-
MDS iNET 900®
2 ページ
-
Multilin™ PQM II
8 ページ
-
Multilin L90
10 ページ
-
COSI
2 ページ
-
Reason DR60
4 ページ
-
Multilin 850
4 ページ
-
G650
8 ページ
-
Hydran M2
2 ページ
-
MultiLink ML3000 Series
12 ページ
-
TN1U
4 ページ
-
Multilin™ MM200
8 ページ
-
Multilin™ MM300
8 ページ
-
Multilin 339
16 ページ
-
Multilin 469
10 ページ
-
Multilin A60
6 ページ
-
Multilin 350
16 ページ
-
Multilin F650
12 ページ
-
Multilin 750/760
10 ページ
-
F35
8 ページ
-
345
12 ページ
-
745
8 ページ
-
Multilin G30
9 ページ
-
Air-Core Reactors
8 ページ
-
Multilin UR & URPlus
18 ページ
-
Multilin C30
6 ページ
-
Voltage Regulators
16 ページ
-
g3 Technology
2 ページ
-
Rectifier
4 ページ
-
RMIO
2 ページ
-
MiCOM Agile P54A/B
2 ページ
-
MultiSync™ 100
6 ページ
-
Multilin G60
9 ページ
-
Multilin D400
12 ページ
-
GL 107X
2 ページ
-
Disconnectors
12 ページ
-
CGVB-05
2 ページ
-
KOTEF
4 ページ
-
FK
4 ページ
-
B65
4 ページ
-
COSI-RogoFlex
2 ページ
-
Grid-GA-L3-COSI_CEVT
2 ページ
-
MiCOM Agile P24x
8 ページ
-
239 Motor Protection
8 ページ
-
Power Transformers
8 ページ
-
smorb
3 ページ
-
MIF II
8 ページ
-
SR family
2 ページ
-
735/737
4 ページ
-
hid
2 ページ
-
dtp
5 ページ
-
IEC Oil Filled & SF
12 ページ
-
Gas Insulated Switchgear
24 ページ
-
Multilin UR & UR Plus
18 ページ
-
M60
8 ページ