G650
1 / 8ページ

{{requestButtons}}

カタログの抜粋

G650 - 1

Generator Protection G650 Generator Protection & Control System Protection, control and monitoring for generator interconnection Key Benefits • Complete distributed generator interconnection protection with two protection options, Basic Protection and Enhanced Protection, to fit your generator protection requirements. • Reduced system event analyzing time and cost through integrated Sequence of Event reports, Oscillography recording, and Trending files. • Preconfigured with Logic for standard Tripping and Closing operation. • Flexible and cost effective control for complex systems through the use of IEC61131 compatible programmable logic to customize the relay’s operation • Reduce installation space requirements with a compact design incorporating protection, control, programmable pushbuttons, programmable LEDs, and communication interfaces • Minimized communication down time through reliable redundant Ethernet Communication ports Applications • Protection of small to medium sized Induction or Synchronous Generators • Stand-alone or component in automated substation control system • Distributed generation and interconnection protection, management, and control where programmable logic is a requirement to interact with prime mover control system Features Basic Protection Option • Phase, Neutral, Ground and Negative Sequence TOC and IOC • Neutral and Ground Directional Overcurrent • Voltage Restraint Overcurrent • Phase Under and Overvoltage, Neutral and Ground Overvoltage • Directional Power • Under and Overfrequency, and Frequency Rate of Change • Generator Thermal Model • Generator Current unbalance • Loss of Excitation • Inadvertent Generator Energization Enhanced Protection Option (Includes all Basic functions) • Sensitive Ground Overcurrent • Volts/Hz • Power Factor limiting • Vector surge loss of mains detection • Breaker Failure • VT Fuse failure • Restricted Ground Fault G650 Generator Digital Energy System Protection & Control • Current, voltage, power, power factor, frequency metering, demand • Breaker condition monitoring including breaker arcing current (I2t) trip counters, and trip circuit monitoring • Event Recorder - 479 time tagged events, with 1ms time resolution • High resolution oscillography and Data Logger, with programmable sampling rate • Fault locator, record of last 10 faults Communications • Standard serial interface with RS232 , optional USB port - up to 115,200 bps • Optional second rear RS485 or serial fiber plastic or glass fiber optic port • Ethernet Ports – 10/100 Base TX, 100 Base FX with ST connectors, options for redundancy available • Multiple protocols - ModBus™ RTU and over TCP/IP, DNP 3.0 Level 2, IEC 60870-5-104, Http, and tftp. EnerVistaTM Software • State of the art software for configuration and commissioning GE Multilin products • Document and software archiving toolset to ensure reference material and device utilities are up-to-date • EnerVistaTM Integrator providing easy integrati

カタログの1ページ目を開く
G650 - 2

G650 Generator Protection & Control System Generator Protection • Trip the incoming feeder breaker in cases where the generator must remain on line to maintain service to essential loads. The G650 is a distributed generation protection and control system designed to protect and control small to medium size generators, as well as to operate as a distributed generation interconnection protection system. All the elements required by international standards to protect a distributed generator have been integrated into a single package for a cost-effective, reliable and simple solution....

カタログの2ページ目を開く
G650 - 3

g650 Generator Protection & Control System Use the G650 for the detection of the loss of excitation of synchronous generators, and to automatically remove the generator from service. Loss of excitation can be damaging to the machine, and/or detrimental to the operation of the system. It is recommended that loss-of-excitation protection be considered for all synchronous generators. Protective relays are applied as backup protection for excitation systems, which in most cases include minimum-excitation limiters to prevent under-excitation. An offset mho characteristic was chosen to provide...

カタログの3ページ目を開く
G650 - 4

G650 Generator Protection & Control System Generator Protection Programmable Control Logic • Power factor (per phase and total) • System Frequency and Frequency Decay Rate These signals are available for local display, and accessible remotely using communications. Oscillography Up to 20 simultaneous Oscillography records can be recorded to monitor up to 9 fixed analog variables (IA, IB, IC, IG, IS,VI, VII, VIII and VX) and any physical I/O point or internal digital operand (up to 16 configurable channels). The waveform traces and digital states provide a visual display of power system and...

カタログの4ページ目を開く
G650 - 5

g650 Generator Protection & Control System EnerVistaTM Software Viewpoint Monitoring The G650 supports a wide range of communication mediums and protocols compatible with new and existing communication infrastructures. The G650 includes a maximum of three independent communication ports: COM1, COM2 and COM3, with many physical choices through the use of two removable plug and play boards. COM1 and COM2 support Modbus® RTU, and serial DNP 3.0. They are located in the first plug and play board, with three different media choices: RS-485, and plastic or glass fiber optic. In addition, COM2 is...

カタログの5ページ目を開く
G650 - 6

G650 Generator Controller System Generator Protection G650 Generator Protection & Control System User Interface

カタログの6ページ目を開く
G650 - 7

G650 Generator Controller System Generator Protection g650 Generator Protection & Control System Typical Wiring C CONTROL POWER SUPPLY BACKUP POWER BACKUP READY Digital Energy Multilin G650 Generator Protection and Control System FIBER FIBER FIBER POWER VOLTAGE INPUTS CURRENT INPUTS REDUNDANT POWER SUPPLY GROUNDING SCREW ANALOG INPUTS CONFIGURABLE OUTPUTS ANALOG INPUTS USER CONFIGURABLE INPUTS CONFIGURABLE OUTPUTS CONFIGURABLE OUTPUTS USER CONFIGURABLE INPUTS OPTIONAL ELEMENTS USER CONFIGURABLE INPUTS GROUND AT RELAY LOCATION (NOT CT & PT LOCATION) USER CONFIGURABLE INPUTS USER CONFIGURABLE...

カタログの7ページ目を開く

GE Grid Solutionsのすべてのカタログと技術パンフレット

  1. Kelman TRANSFIX

    2 ページ

  2. Kelman MINITRANS

    2 ページ

  3. MIG

    3 ページ

  4. DTR

    4 ページ

  5. SPM

    8 ページ

  6. TOV

    3 ページ

  7. MDS SD Series

    4 ページ

  8. MIC

    2 ページ

  9. Multilin F60

    9 ページ

  10. Model PT6-2-125

    2 ページ

  11. Model PT6-1-125

    2 ページ

  12. Model 3PT3-60

    2 ページ

  13. MIG II

    8 ページ

  14. Model JVW-110C

    2 ページ

  15. Model JVW-5AC-1

    2 ページ

  16. Model JVW-5C

    2 ページ

  17. Multilin T60

    9 ページ

  18. Multilin 489

    9 ページ

  19. Multilin™ D25

    8 ページ

  20. Multilin D485

    1 ページ

  21. Multilin P485

    1 ページ

  22. MultiNet

    3 ページ

  23. iNET-II

    4 ページ

  24. MDS™ iNET 300

    2 ページ

  25. MDS iNET 900®

    2 ページ

  26. Multilin™ PQM II

    8 ページ

  27. Multilin L90

    10 ページ

  28. COSI

    2 ページ

  29. Reason DR60

    4 ページ

  30. Multilin 850

    4 ページ

  31. Hydran M2

    2 ページ

  32. TN1U

    4 ページ

  33. Multilin™ MM200

    8 ページ

  34. Multilin™ MM300

    8 ページ

  35. Multilin 339

    16 ページ

  36. Multilin 469

    10 ページ

  37. Multilin A60

    6 ページ

  38. Multilin 350

    16 ページ

  39. Multilin F650

    12 ページ

  40. Multilin 750/760

    10 ページ

  41. F35

    8 ページ

  42. 345

    12 ページ

  43. 745

    8 ページ

  44. Multilin G30

    9 ページ

  45. Air-Core Reactors

    8 ページ

  46. Multilin UR & URPlus

    18 ページ

  47. Multilin C30

    6 ページ

  48. Voltage Regulators

    16 ページ

  49. g3 Technology

    2 ページ

  50. Rectifier

    4 ページ

  51. RMIO

    2 ページ

  52. MiCOM Agile P54A/B

    2 ページ

  53. MultiSync™ 100

    6 ページ

  54. Multilin G60

    9 ページ

  55. Multilin D400

    12 ページ

  56. GL 107X

    2 ページ

  57. Disconnectors

    12 ページ

  58. CGVB-05

    2 ページ

  59. KOTEF

    4 ページ

  60. FK

    4 ページ

  61. B65

    4 ページ

  62. COSI-RogoFlex

    2 ページ

  63. MiCOM Agile P24x

    8 ページ

  64. Power Transformers

    8 ページ

  65. smorb

    3 ページ

  66. MIF II

    8 ページ

  67. SR family

    2 ページ

  68. 735/737

    4 ページ

  69. hid

    2 ページ

  70. dtp

    5 ページ

  71. IEC Oil Filled & SF

    12 ページ

  72. M60

    8 ページ