
カタログの抜粋

DDS Digital Transformer Protection High-speed, three-phase differential protection for transformer faults. ■ Multiple, configurable digital l/Os ■ Transformer configuration selection ■ Software winding connection compensation ■ Enhanced capabilities to ease servicing ■ GE-NESIS Windows®-based programming ■ High-speed differential and backup instantaneous differential three-phase protection functions for power trans- formers with two, three or four windings I enerVista.com compatible (see page 275) ■ Current differential protection ■ Dual-slope percentage restraint ■ Event and oscillography recording User Interfaces ■ 20 character keypad, alphanumeric two- ■ RS232, RS485, plastic or glass fiber optic ■ ModBus® communication protocol available
カタログの1ページ目を開く
DTP DDS Digital Transformer Protection Protection and Control The DTP is a digital relay that provides high-speed differential and backup instantaneous differential three-phase protection for power transformers with two, three or four windings. Differential Protection For high-magnitude external faults, the DTP uses a current differential with percentage restraint to compensate for unbalance caused by variation in CT outputs. The DTP differential unit has programmable dual-slope percentage restraint with adjustable slope breakpoint. Discrete Fourier Transformation (DFT) provides excellent...
カタログの2ページ目を開く
DTP DDS Digital Transformer Protection record has a maximum capacity of 66 cycles. The number of prefault cycles can be selected from two to 10 cycles. Each of the records includes the following information: I Instantaneous values for current A keypad and display allow local communication. Self-Checking Functions Self-checking functions at startup and during normal operation will block operation if an error is detected. Additionally, the TARGET RESET button allows testing of LED. Setting Tables The DTP has three independent setting tables, stored in nonvolatile memory. Only one table may be...
カタログの3ページ目を開く
DTP DDS Digital Transformer Protection The communications protocol requires the use of the GE-LOCAL software to facilitate communication with different protection systems. It guarantees efficient data transfer (especially for oscillography and other large files) along with error detection and automatic communication recovery. I GE-INTRO enables the user to con- Two Windows -based software packages are included with the DTP: I GE-LOCAL enables the user to ® As an option, GE-OSC software enables the user to study the oscillography records. visualize the protection settings, alarms, LEDs,...
カタログの4ページ目を開く
DTP DDS Digital Transformer Protection DTP Technical Specifications PROTECTION General settings: Frequency: Winding CT ratio: Protection settings: Winding tap: Winding configuration: Winding time group: Winding CT configuration: Differential function settings: Sensitivity: K1 percentage restraint: K2 percentage restraint: K1 – K2 inflexion: 2nd harmonic restraint: 5th harmonic restraint: 87B tap: COMMUNICATIONS Mode: Half duplex Speed: 1200 to 19200 bps Physical media: RS232 (ports 1, 3) RS485 (port 2 optional) Plastic fiber optic (port 2 optional) Type of connector: HFBR-4516 Power...
カタログの5ページ目を開くGE Grid Solutionsのすべてのカタログと技術パンフレット
-
Kelman TRANSFIX
2 ページ
-
Kelman MINITRANS
2 ページ
-
MIG
3 ページ
-
DTR
4 ページ
-
SPM
8 ページ
-
TOV
3 ページ
-
MDS SD Series
4 ページ
-
MIC
2 ページ
-
Multilin F60
9 ページ
-
Model PT6-2-125
2 ページ
-
Model PT6-1-125
2 ページ
-
Model 3PT3-60
2 ページ
-
MIG II
8 ページ
-
Model JVW-110C
2 ページ
-
Model JVW-5AC-1
2 ページ
-
Model JVW-5C
2 ページ
-
Multilin T60
9 ページ
-
Multilin 489
9 ページ
-
Multilin™ D25
8 ページ
-
Multilin D485
1 ページ
-
Multilin P485
1 ページ
-
MultiNet
3 ページ
-
iNET-II
4 ページ
-
MDS™ iNET 300
2 ページ
-
MDS iNET 900®
2 ページ
-
Multilin™ PQM II
8 ページ
-
Multilin L90
10 ページ
-
COSI
2 ページ
-
Reason DR60
4 ページ
-
Multilin 850
4 ページ
-
G650
8 ページ
-
Hydran M2
2 ページ
-
MultiLink ML3000 Series
12 ページ
-
TN1U
4 ページ
-
Multilin™ MM200
8 ページ
-
Multilin™ MM300
8 ページ
-
Multilin 339
16 ページ
-
Multilin 469
10 ページ
-
Multilin A60
6 ページ
-
Multilin 350
16 ページ
-
Multilin F650
12 ページ
-
Multilin 750/760
10 ページ
-
F35
8 ページ
-
345
12 ページ
-
745
8 ページ
-
Multilin G30
9 ページ
-
Air-Core Reactors
8 ページ
-
Multilin UR & URPlus
18 ページ
-
Multilin C30
6 ページ
-
Voltage Regulators
16 ページ
-
g3 Technology
2 ページ
-
Rectifier
4 ページ
-
RMIO
2 ページ
-
MiCOM Agile P54A/B
2 ページ
-
MultiSync™ 100
6 ページ
-
Multilin G60
9 ページ
-
Multilin D400
12 ページ
-
GL 107X
2 ページ
-
Disconnectors
12 ページ
-
CGVB-05
2 ページ
-
KOTEF
4 ページ
-
FK
4 ページ
-
B65
4 ページ
-
COSI-RogoFlex
2 ページ
-
Grid-GA-L3-COSI_CEVT
2 ページ
-
MiCOM Agile P24x
8 ページ
-
239 Motor Protection
8 ページ
-
Power Transformers
8 ページ
-
smorb
3 ページ
-
MIF II
8 ページ
-
SR family
2 ページ
-
735/737
4 ページ
-
hid
2 ページ
-
IEC Oil Filled & SF
12 ページ
-
Gas Insulated Switchgear
24 ページ
-
Multilin UR & UR Plus
18 ページ
-
M60
8 ページ