カタログの抜粋

Bulletin 71.2:299H September 2012 299H Series Pressure Reducing Regulators • Inlet Pressure up to 175 psig / 12.1 bar • ±1% Accuracy for Fixed Factor Billing (PFM) • Rugged Construction • Compact • Easy to Maintain • Integral Pilot W7513 Figure 1. 299H Series Pressure Reducing Regulators • Optional Slam-Shut Configuration • No Bleed Monitor • High Capacity • Robust • Outlet Pressures up to 60 psig / 4.1 bar • Optional Token Relief www.fisherregulators.com D102683X012 • External, Internal, or Dual Registration
カタログの1ページ目を開く
Bulletin 71.2:299H Specifications Specifications for 299H Series constructions are given below. Some specifications for a given regulator as it originally comes from the factory are stamped on a nameplate located on the actuator upper casing. Available Constructions Type 299H: Pilot-operated pressure reducing regulator with a pilot integrally mounted to the actuator casing. Type 299HR: A Type 299H with a token internal relief valve to relieve minor overpressure caused by thermal expansion. Type 299HS: Same as the Type 299H with a Type VSX-2 slam-shut valve which provides overpressure or...
カタログの2ページ目を開く
Bulletin 71.2:299H 3/4 NPT CONTROL LINE W7527-1 W7528-1 TYPE 299H WITH EXTERNAL REGISTRATION TYPE 299HR PILOT WITH OPTIONAL TOKEN RELIEF Figure 2. 299H Series Sectional Views Features • Compact in Size—Small envelope because of the built-in pilot and internal registration. • Unique No Bleed Monitor System—Flexible worker/monitor system setup that allows for bleed to be piped to the intermediate piping thus eliminating downstream bleed which reduces lost and unaccounted for gas. Another advantage of this configuration is that the system lockup pressure is that of the worker instead of the...
カタログの3ページ目を開く
Bulletin 71.2:299H Introduction Principle of Operation Description Letter keys in this section refer to Figure 3 unless otherwise noted. Fast response and accuracy are made possible by the amplifying effect of the pilot and by the two-path control system. The function of the pilot is to sense change in the controlled outlet pressure and amplify it into a larger change in the loading pressure. Any changes in outlet pressure act quickly on both the actuator diaphragm and the loading pilot, thus providing the precise pressure control and fast speed of response that is characteristic of a...
カタログの4ページ目を開く
Bulletin 71.2:299H B J OUTLET E H INLET 3/4 NPT CONTROL LINE CONNECTION K PILOT SUPPLY SCREEN G A C F A7268_1 TYPE 299H WITH INTERNAL REGISTRATION J 3/4 NPT DOWNSTREAM CONTROL LINE CONNECTION J 3/4 NPT DOWNSTREAM CONTROL LINE CONNECTION G A7269 EXTERNAL REGISTRATION A7270 G DUAL REGISTRATION INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE LOADING PRESSURE Figure 3. Type 299H Operational Schematic A7272 A7271 TOKEN RELIEF CLOSED TOKEN RELIEF OPEN Figure 4. Type 299HR Operational Schematic 5
カタログの5ページ目を開く
HS Type 299HS Bulletin 71.2:299H July 2008 Type 299HS TERNAL REGISTRATION EXTERNAL REGISTRATION EXTERNAL REGISTRATION INTERNAL REGISTRATION TERNAL REGISTRATION E0072 E0072 INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE LOADING PRESSURE E0072 URE SURE C PRESSURE SSURE INTERNAL REGISTRATION INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE LOADING PRESSURE Figure 5. Type 299HS Operational Schematic Type 299H In operation, assume the outlet pressure is less than the setting of pilot control spring (A). The top side of pilot diaphragm assembly (F) will have a lower pressure than the...
カタログの6ページ目を開く
Table 1. Body Sizes and End Connection Styles Table 2. Outlet Pressure Ranges Refer to Figure 5. The Type VSX-2 slam-shut device on the Type 299HS regulator is a fast acting slam-shut valve which provides overpressure or overpressure and underpressure protection by completely shutting off the flow of gas to the downstream system. The slam-shut module's actions are independent of the Type 299HS main regulator and of variations to the inlet pressure. The Type VSX-2 has internal or external registration. External registration requires a downstream sensing line. The slam-shut disk is held in...
カタログの7ページ目を開く
OPTIONAL PILOT SUPPLY FILTER OR FILTERED PILOT ' SUPPLY REGULATOR OPTIONAL PILOT SUPPLY REGULATOR OPTIONAL PILOT OPTIONAL PILOT SUPPLY FILTER OR FILTERED PILOT SUPPLY REGULATOR NOTE: IF USED, THE PILOT SUPPLY REGULATOR SHOULD BE SET TO 3 psig / 0.21 bar ABOVE THE MONITOR OUTLET PRESSURE SETTING. NOTE: IF USED, THE PILOT SUPPLY REGULATOR SHOULD BE SET TO 3 psig / 0.21 bar ABOVE THE MONITOR OUTLET PRESSURE SETTING. WIDE-OPEN DOWNSTREAM MONITOR WIDE-OPEN UPSTREAM MONITOR .OPTIONAL PILOT SUPPLY REGULATOR OPTIONAL PILOT SUPPLY FILTER OR FILTERED PILOT SUPPLY REGULATOR OPTIONAL PILOT FILTERED...
カタログの8ページ目を開く
Table 3. Flow Coefficients Table 4. Type VSX-2 High and Low Trip Pressure Ranges
カタログの9ページ目を開く
Bulletin 71.2:299H Wide-Open Monitor The control line of the upstream regulator is connected downstream of the second regulator (Figure 6), so that during normal operation the monitoring regulator is standing wide open with the reduction to distribution pressure being taken across the working regulator. Only in case of open failure of the working regulator does the wide-open monitoring regulator take control at its slightly higher setting. A pressure build-up above the monitor set pressure is required for the monitor to take control in the event of an overpressure situation. Installing a...
カタログの10ページ目を開く
Table 5. Types 299H and 299HR Flow Capacities'1' for 1-1/2 NPT and NPS 2/DN 50 External/Dual Registration
カタログの11ページ目を開く
Table 5. Types 299H and 299HR Flow Capacities'1' for 1-1/2 NPT and NPS 2/DN 50 External/Dual Registration (continued)
カタログの12ページ目を開く
Table 5. Types 299H and 299HR Flow Capacities'1' for 1-1/2 NPT and NPS 2/DN 50 External/Dual Registration (continued)
カタログの13ページ目を開く
Table 6. Types 299H and 299HR Flow Capacities'1' for 1-1/2 NPT Internal Registration
カタログの14ページ目を開く
Table 6. Types 299H and 299HR Flow Capacities'1' for 1-1/2 NPT Internal Registration (continued)
カタログの15ページ目を開く
Table 6. Types 299H and 299HR Flow Capacities'1' for 1-1/2 NPT Internal Registration (continued)
カタログの16ページ目を開くFISHER REGULATORSのすべてのカタログと技術パンフレット
-
R Series
2 ページ
-
LP-Gas Technologies
118 ページ
-
Type 630 Regulator
16 ページ
-
easy-e Cryogenic Valves
12 ページ
-
Large ET and ED Valves
20 ページ
-
Air Application Map
1 ページ
-
CSI 6500 Overview
12 ページ
-
DeltaV Smart Switches
28 ページ
-
Smartprocess™ Heater
5 ページ
-
LP-31
96 ページ
-
CS 200 series
2 ページ
-
Regulators Mini Catalog
24 ページ
-
1301F, 1301G
12 ページ
-
MR95 and MR98
2 ページ
-
Fisher® D and DA Valves
12 ページ
-
Fisher® 377 Trip Valve
20 ページ
-
630 Regulator
16 ページ
-
ACE97 Pad-Depad Valve
16 ページ
-
S200 series
32 ページ
-
R622 series
8 ページ
-
cs200 series
40 ページ
-
CS400 Series
60 ページ
カタログアーカイブ
-
Pressure Equivalents
1 ページ