カタログの抜粋

High Power relay 100 A Power generators Back-up generators Pump control Disabled lift Charging Stations
カタログの1ページ目を開く
FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.
カタログの2ページ目を開く
68 SERIES High Power relay 100 A Printed circuit mount - 3.6 mm contact gap Relay for applications with high power Type 68.22-4300 - 2 NO • DC coils, with only 700 mW holding power • Reinforced insulation between coil and contacts • Suitable for use at ambient temperatures up • 2 NO • Contact gap 3.6 mm • PCB mount • Meets the EN 60335-1 requirements of resistance to heat and fire (GWIT 775 °C and GWFI 850 °C) • Cadmium free contact materials For outline drawing see page 6 Copper side view Contact specification Contact configuration Rated current/ Maximum peak current (for 1 ms) Rated...
カタログの3ページ目を開く
68 SERIES High Power relay 100 A Ordering information Example: 68 series, power relay for printed circuit, 2 NO contacts, 12 V DC coil. A: Contact material 4 = tandard AgSnO2 S Type 2 = -phase PCB terminals, 3 1.5 mm gap between PCB and relay base No. of poles 2 = pole 2 D: Special versions 0 = tandard S B: Contact circuit 3 = NO, ≥ 3.6 mm contact gap Coil version 9= C D Coil voltage See coil specifications Technical data Insulation according to EN 61810-1 Nominal voltage of supply system Rated insulation voltage Pollution degree Insulation between coil and contact set Type of Insulation...
カタログの4ページ目を開く
68 SERIES High Power relay 100 A Contact specification F 68 - Electrical life v contact current NOTE: for ambient temperatures between 70 and 85 ° C, the electrical life is reduced by 30% H 68 - Maximum DC breaking capacity When switching a resistive (DC1) or inductive (DC13) load having voltage and current values under the corresponding curve, an electrical life of > 30000 cycles can be expected. NOTE: The heating and electrical endurance tests have been performed on relays soldered on PC boards having the following characteristics: double side, copper thickness >105 μm, contact tracks...
カタログの5ページ目を開く
68 SERIES High Power relay 100 A Coil specifications DC coil data Nominal voltage Coil code Holding voltage Rated coil consumption I at UN R 68-1 - perating range v ambient temperature, O with standard (continuous) coil energization (–40…+70)°C 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. R 68-2 - perating range v ambient temperature, O in energy saving mode (–40…+85)°C Energy saving mode In some applications, such as photovoltaic inverters, it may be necessary to minimize the overall relay power dissipation and to permit use at higher ambient...
カタログの6ページ目を開くFINDER S.p.A. con unico socioのすべてのカタログと技術パンフレット
-
CATALOGUE
900 ページ
-
RAILWAY APPLICATIONS
8 ページ
-
MARINE APPLICATIONS
7 ページ
-
SELECTION GUIDE
16 ページ
-
7M Smart energy meters
14 ページ
-
YESLY 13 SERIES
4 ページ
-
30 SERIES
6 ページ
-
Product News 70
2 ページ
-
Product News SAFE
2 ページ
-
Product News 7S
2 ページ
-
Series 22
5 ページ
-
Product News 39
5 ページ
-
66 Series
10 ページ
-
Brochure 58
8 ページ
-
Product News ATEXUSA
2 ページ
-
Product News ATEX
2 ページ
-
General catalog
587 ページ
-
Série 43
4 ページ
-
Serie 40
20 ページ
-
Series 20
4 ページ
-
Série 13
2 ページ
-
32 SERIES
4 ページ
-
Series 77
2 ページ
-
50 series
4 ページ
-
48 Series
10 ページ
-
46 Series
10 ページ