グループ: Gilbarco Veeder-Root

カタログの抜粋

The alarm system for oil and light liquid separators Sensors & Systems Worldwide: www.fafnir.com
カタログの1ページ目を開く
FAFNIR GmbH: Innovation with Tradition. Quality and Satisfaction – made in Germany Company FAFNIR GmbH was founded in Hamburg in 1965. The traditional company continues to impress with innovative products, reliable quality and a strong focus on customers and service in the area of sensors and systems for process control optimisation. This long-established company develops and produces overfill prevention devices, overfill protection devices, limit signal controls and continuous filling level measurement for every type of liquid, and puts a strong emphasis on human and environmental safety....
カタログの2ページ目を開く
SEPARIX The alarm system for oil and light liquid separators Edition 02.20 Subject to technical modifications without notice Features of FAFNIR Technology Product information Oil and light fluids present a huge danger potential for ground and waste water. The alarm system SEPARIX is the ideal sensor technology to alert the operator of separators in time of this danger. ■ Suitable for all oil and light liquid separators ■ ATEX approval for zone 0 Range of application The separator alarm system SEPARIX is suitable for all kinds of light fluids, in particular for petrol, mineral oil...
カタログの3ページ目を開く
SEPARIX-T L Plus At the response point of the high-level sensor is an encapsulated PTC resistor. The PTC resistor is a variable resistor whose resistance value increases with rising temperature. As liquids have better thermal conductivity values than air or gas, the PTC resistor heats up more strongly in the air or gas. When immersed into liquid, the PTC resistor cools down. The change of resistance value is evaluated by the SEPARIX-Control CT. The correct function of the high-level sensor is permanently monitored with a scanner function. Function SEPARIX-C L Plus A cylindrical capacitor is...
カタログの4ページ目を開く
Technical Data SEPARIX-C L Plus interface sensor Operating data » Ambient temperature: -20 °C to +60 °C (for use in Ex zones); -20 °C to +70 °C » Medium temperature: 0 °C to +60 °C (for use in Ex zones); 0 °C to +70 °C » Protection class: IP68 Materials of wetted parts » Stainless steel (1.4305/303), PE-HD (high density polyethylene) Dimensions » Diameter: 34 mm » Length: 178 mm » Cable length: 5.0 m (prolongable up to 250 m) » Further data: see drawing Explosion protection » II 1 G Ex ia IIB T4 Ga Approval » Ex (ATEX) SEPARIX-T L Plus high-level sensor Operating data » Product temperature:...
カタログの5ページ目を開く
Technical drawing Interface sensor SEPARIX-C L Plus High-level sensor SEPARIX-T L Plus Response point Response point Edition 02.20 Subject to technical modifications without notice 6 | SEPARIX – Technical Data
カタログの6ページ目を開く
Edition 02.20 Subject to technical modifications without notice SEPARIX - Order codes SEPARIX - Order code 7
カタログの7ページ目を開く
FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg, Germany Phone: +49/40/39 82 07-0 E-mail: info@fafnir.com Internet: www.fafnir.com
カタログの8ページ目を開くFAFNIR GmbHのすべてのカタログと技術パンフレット
-
TORRIX M12 MOBILE
2 ページ
-
TORRIX XTS
2 ページ
-
TORRIX 6
1 ページ
-
LPG Sensors
8 ページ
-
Process Automation
28 ページ
-
O²-PID
4 ページ
-
COMS Leaflet
4 ページ
-
VAPORIX Flow and Control
40 ページ
-
Wallmounting Typ 907
4 ページ
-
QE 200
4 ページ
-
UM 2.1/2.2/2.3
20 ページ
-
TORRIX HART
28 ページ
-
TORRIX RS485 Modbus
16 ページ
-
TORRIX M12
40 ページ
-
FAFNIR Hart Setup
9 ページ
-
LS 300 / 500
7 ページ
-
76 A / NB 220
5 ページ
-
76 / NB 220
2 ページ
-
SECON-X
4 ページ
-
PRESSURIX
12 ページ
-
Insite360
4 ページ
-
Plugs
12 ページ
-
UM 2.1/UM 2.2/UM 2.3
20 ページ
-
TORRIX-HART
28 ページ
-
DIVELIX
8 ページ
-
CONDURIX-HART
28 ページ
-
CONDURIX
24 ページ
-
VAPORIX
12 ページ
-
VISY-X
24 ページ
-
Accessories
3 ページ
-
VISY-Command Web
4 ページ
-
VISY-Reed
4 ページ
-
VISY-RF
2 ページ
-
VISY-Stick
15 ページ
-
VISY-TD Display
2 ページ
-
VISY-View Touch
2 ページ
-
TORRIX
10 ページ
-
TORRIX CI
1 ページ
-
TORRIX RS485
3 ページ
-
UM-X Transducer
3 ページ
-
TEMPERIX
8 ページ
-
VISY-Command
5 ページ
-
LPG-Sensoren
8 ページ
カタログアーカイブ
-
2019 VISY-Stick Flex
2 ページ
-
2016 VISY-Stick Flex
2 ページ
-
HPH Ex d
3 ページ
-
VISY-Monitor
2 ページ
-
VISY-X LON
10 ページ
-
SEPARIX
23 ページ
-
VAPORIX Flow/Control
32 ページ
-
VISY-Setup V 3.1.0
40 ページ
-
VISY-Setup V2.10
42 ページ
-
VISY-View
24 ページ