グループ: Gilbarco Veeder-Root

カタログの抜粋

Overfill Prevention and its components Sensors & Systems Worldwide: www.fafnir.com
カタログの1ページ目を開く
FAFNIR – Quality and Satisfaction Company: FAFNIR GmbH, based in Hamburg, Germany, has over 45 years of experience in the development and production of filling safety devices, overfill prevention solutions, limit ignal controls lers and continuous level gauging solutions for all types of liquid. The optimisation of process controls, improvements in cost efficiency and the protection of people and the environment are at the heart of our business. Our close and trusting relationship with our c ustomers is a key factor in the practice- riented o implementation of innovative ideas and the...
カタログの2ページ目を開く
Overfill Prevention Type 83-UV The Overfill Prevention Sensor GWG and QSS/ASS Plugs date of issue 08.16 Subject to technical change The overfill prevention sensor GWG with tube plug type 907 Application The filling sensor is a safety mechanism to prevent overfilling of storage and bunker tanks when they are filled with gasoline, diesel, and fuel oil from road tankers. It consists of a level sensor inside the tank and a amplifier with valve inside the road tanker. The QSS/ASS plugs are part of a safety system that prevents the blending of products due to a faulty connection and that checks...
カタログの3ページ目を開く
The Filling System GWG-, QSS-, ASS-Signals Connecting cable with junktion box Overfill prevention sensor with tube plugs Our Terminology Overfill prevention sensor: GWG; Quality assurance system or product detection: QSS; Filling hose safety device: ASS As liquids are better thermal conductors than air or gas, the PTC-resistor heats up better in air or gas. When dipped into liquid, the PTC-resistor is cooled down, and the changing resistance value is interpreted by the amplifier. The amplifier controls a solenoid valve which is part of the control chain of the valve. If the threshold point...
カタログの4ページ目を開く
GWG GWG with pipe fitting GWG for distant installation with wall fitting Ø 60 Fitting for pipe installation Typ 907 Probe length engraved Probe length (100 - 3,000 mm) Threshold length "X" 10 18 42 Marking slot Locking screw WAF 5 Cable screwing PG Connection cable 2 x 1 mm2, location sided Threshold point Materials »» Parts in contact with product: brass, stainless steel, galvanised spring steel, solder, viton, ultradur »» Plugs: brass and nickel-plated brass Dimensions »» Tube diameter: brass 24 x 2, stainless steel 24 x 1 Technical Data Operating data »» Product temperature: - 25 °C to...
カタログの5ページ目を開く
Order Code Overfill Prevention Sensor Type / probe tube 81 D-Ex U / stainless steel 24 x 1 81 D-Ex / stainless steel 24 x 1 83 UV / brass 24 x 2 84 UVT (telescopic) / brass 24 x 2 Two-digit code: Length in mm /100 (e. g. 1,500 mm = 15) 84 UVT only available with length 600 mm and 900 mm (code: 06 or 09) Junction box for remote installation Pipe plugs (basis) Pipe plugs (basis) for ASS Junction box and wall plugs (bottom part) for remote installation Junction box and wall plugs (bottom part) for remote installation for ASS Junction box and wall plugs (bottom part) for remote installation for...
カタログの6ページ目を開く
Coded Electrical Plug Connection Type FP 903/907 ASS K for QSS and ASS date of issue 08.16 Subject to technical change Coupling Type 903 ASS K Wall plug Type 907 ASS K Application The product regognition QSS is a device to prevent the mixing of fuels or other liquids during the filling of a storage or bunker tank from a road tanker. The filling hose safety device ASS monitors the correct connection of the filling hose to such tanks. The FAFNIR QSS/ ASS solutions consist of a plug on the tank and a coupling on the road tanker. The release signal for the filling process is performed by an...
カタログの7ページ目を開く
Our Terminology Overfill prevention sensor: GWG; Quality assurance system or product recognition: QSS; Filling hose safety device: ASS Function The QSS functions are carried out by the simple pairing of magnetic reed sensor coding between the plug (wall plugs) and the mobile coupling. The analysis is based on the principle ”2 out of 4”, thus corresponding to a high safety standard. Six d ifferent codes are vailable. a Design The coupling type 903 ASS K consists of »» Connection cable »» Protective hose »» Coupling with: – GWG with contact sockets – Reed sensors – Push contacts The wall...
カタログの8ページ目を開く
Product Regognition Coupling Ø 60 Fitting for wall mounting Type 907 105 9-wire cable (2 x 1 mm2 and 7 x 0.25 mm2) 15 m long Jacket substance: PUR Screwed cable gland Connecting cable installation side Protection hose Ø16 1,000 long Material: PA Screwed cable gland hose PG11 Material: PA6.6 Technical Data Operating data »» Umgebungstemperatur: - 25 °C to + 50 °C »» Resistant to all products according to the GWG list of substances Dimensionen Coupling »» Connection cable: Ø 7 mm x 15 m standard »» Protective hose: Ø 16 mm x 1,000 mm »» Housing: Ø 60 mm x 137 mm »» Other data: see...
カタログの9ページ目を開く
The Overfill Prevention Sensor Testing Device ME 6 Application Overfill prevention sensors must be checked on a regular basis. This is usually performed during a tank inspection. An optimal and safe check of overfill pre vention sensors is guaranteed by the overfill prevention sensor testing device ME 6. Features of FAFNIR technology Genuine function check Easy menu-driven operation Handy design Suitable for all overfill prevention sensors with PTC technology Certified for overfill prevention sensors in explosive atmospheres Simultaneous check of the QSS coding Driven by storage batteries...
カタログの10ページ目を開く
Our Terminology Overfill prevention sensor: GWG; Quality assurance system or product recognition: QSS Function The GWG is heated up by the intrinsically safe current of the testing device. The heating time is measured, analysed and indicated in the touch display. A switching off event is treated in the same manner. The QSS c oding is registered and also displayed. Connection to the GWG The connection of the overfill prevention sensor testing device to the GWG is realised via a coupling type 903 with helix cable. Materials »» Coupling Type 903: PVC, »» Coupling Type 903 QSS: PA6.6 »»...
カタログの11ページ目を開くFAFNIR GmbHのすべてのカタログと技術パンフレット
-
TORRIX M12 MOBILE
2 ページ
-
TORRIX XTS
2 ページ
-
TORRIX 6
1 ページ
-
LPG Sensors
8 ページ
-
SEPARIX
8 ページ
-
Process Automation
28 ページ
-
O²-PID
4 ページ
-
COMS Leaflet
4 ページ
-
VAPORIX Flow and Control
40 ページ
-
Wallmounting Typ 907
4 ページ
-
QE 200
4 ページ
-
UM 2.1/2.2/2.3
20 ページ
-
TORRIX HART
28 ページ
-
TORRIX RS485 Modbus
16 ページ
-
TORRIX M12
40 ページ
-
FAFNIR Hart Setup
9 ページ
-
LS 300 / 500
7 ページ
-
76 A / NB 220
5 ページ
-
76 / NB 220
2 ページ
-
SECON-X
4 ページ
-
PRESSURIX
12 ページ
-
Insite360
4 ページ
-
Plugs
12 ページ
-
UM 2.1/UM 2.2/UM 2.3
20 ページ
-
TORRIX-HART
28 ページ
-
DIVELIX
8 ページ
-
CONDURIX-HART
28 ページ
-
CONDURIX
24 ページ
-
VAPORIX
12 ページ
-
VISY-X
24 ページ
-
Accessories
3 ページ
-
VISY-Command Web
4 ページ
-
VISY-Reed
4 ページ
-
VISY-RF
2 ページ
-
VISY-Stick
15 ページ
-
VISY-TD Display
2 ページ
-
VISY-View Touch
2 ページ
-
TORRIX
10 ページ
-
TORRIX CI
1 ページ
-
TORRIX RS485
3 ページ
-
UM-X Transducer
3 ページ
-
TEMPERIX
8 ページ
-
VISY-Command
5 ページ
-
LPG-Sensoren
8 ページ
カタログアーカイブ
-
2019 VISY-Stick Flex
2 ページ
-
2016 VISY-Stick Flex
2 ページ
-
HPH Ex d
3 ページ
-
VISY-Monitor
2 ページ
-
VISY-X LON
10 ページ
-
SEPARIX
23 ページ
-
VAPORIX Flow/Control
32 ページ
-
VISY-Setup V 3.1.0
40 ページ
-
VISY-Setup V2.10
42 ページ
-
VISY-View
24 ページ