video corpo cad

CTP and CTA Transponder-Coded Safety Switches with Guard Locking
1 / 8ページ

{{requestButtons}}

カタログの抜粋

CTP and CTA Transponder-Coded Safety Switches with Guard Locking - 1

CTP and CTA Transponder-Coded Safety Switches with Guard Locking

カタログの1ページ目を開く
CTP and CTA Transponder-Coded Safety Switches with Guard Locking - 2

The CTP and CTA safety switches The CTP/CTA safety switch combines the proven principle of operation of electromechanical safety switches with guard locking and modern transponder-coded safety engineering. Thanks to the transponder technology, even a single CTP/CTA achieves category 4 / PL e according to EN ISO 13849-1, without additional fault exclusion, and meets all the requirements of EN ISO 14119. It is ideally suited to applications in which a high Performance Level and a high locking force are required. ■ Versatile use The CTP/CTA reliably secures safety doors and flaps on machines...

カタログの2ページ目を開く
CTP and CTA Transponder-Coded Safety Switches with Guard Locking - 3

n Maximum safety Transponder coding ensures maximum safety. The requirements in all relevant standards can be met with just a single CTP/CTA. Irrespective of whether category 4 / PL e according to EN ISO 13849-1 must be achieved or whether the requirements in EN ISO 14119 must be met – you’re always on the safe side with the CTP/CTA. n Different coding levels Depending on the application, safety switches with unicode or multicode evaluation can be used. For unicode evaluation, the actuator is clearly assigned to the safety switch in a teach-in operation. This ensures excellent protection...

カタログの3ページ目を開く
CTP and CTA Transponder-Coded Safety Switches with Guard Locking - 4

Easy to integrate into different applications and systems Be it separate operation, series connection or connection to the higher-level control system via various communication standards -anything is possible thanks to the wide range of CTP/CTA versions available. Devices in the BP system family are suitable for separate operation. EUCHNER 10-Link Gateways can be used to read process and device data from the switch and to send the data to an 10-Link Master in real time. Devices with communication capability are identified by the INDUSTRY 4.0 READY logo. ■ BR system family '^ready^-^ In the...

カタログの4ページ目を開く
CTP and CTA Transponder-Coded Safety Switches with Guard Locking - 6

n Different plug connectors for greater flexibility n Extensive accessories Be it different mechanical releases, pre-assembled cables or different bolt systems, actuators or mounting plates – the comprehensive range of accessories offers maximum flexibility during integration and mounting. Bolt system Emergency release Lockout bar (for up to three locks) Wire front release (bowden)

カタログの6ページ目を開く
CTP and CTA Transponder-Coded Safety Switches with Guard Locking - 8

OUR PRODUCTS FOR YOUR SAFETY RELIABLE DOOR DETECTION Transponder-coded safety switches without guard locking: CES-C04 // CES-C07 Magnetically coded safety switches without guard locking: CMS Electromechanical safety switches without guard locking: NM // NP // GP // NZ SAFE GUARD LOCKING Transponder-coded safety switches with guard locking: CTM // CTP // CTA // CET Electromechanical safety switches with guard locking: STM // TP // STP // STA Safety switches with integrated mounting magnet: CEM-C40 // CEM-C60 DOOR LOCKING SYSTEMS MGB // MGB2 Modular// MGBS ACCESS CONTROL SYSTEMS EKS // EKS...

カタログの8ページ目を開く

EUCHNER GmbH + Co. KGのすべてのカタログと技術パンフレット

  1. Logistics

    5 ページ

  2. News

    6 ページ

  3. IO-Link Safety

    4 ページ

  4. Safety Relays ESM

    32 ページ

  5. Product Guide

    20 ページ

  6. Industry 4.0

    16 ページ

  7. EKS with touch panel

    12 ページ

  8. Safe key system CKS2

    10 ページ

  9. Enabling Switches ZS

    92 ページ

  10. About EUCHNER

    34 ページ

  11. MGBS

    52 ページ

  12. AC-DP-04-SA

    2 ページ

  13. EKS with USB port

    2 ページ

  14. Position Switches

    56 ページ

  15. Joystick Switches

    28 ページ

  16. EKS Light

    8 ページ

カタログアーカイブ