Differential pressure Deltabar PMD75 Differential pressure transmitter with metal sensor for measurement of pressure differences F Best accuracy, reproducibility and long-term stability Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508 Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics Cost savings with modular concept for easy replacement of sensor, display or electronics Overload-resistant up to 420bar / 42MPa / 6300psi, functionmonitored Seamless and independent system integration (HART/PA/FF) More information and current pricing: www.endress.com/PMD75 Accuracy Standard: 0.05% Platinum: up to 0.035% Max. measurement error 0,075% "PLATINUM" 0,05% Process temperature -40 °C...85 °C (-40 °F...185 °F) Medium temperature range Temperature gradient from pressure piping Pressure measuring range 10 mbar...250 bar (0.15 psi...3750 psi) Field of application: The Deltabar PMD75 differential pressure transmitter with piezoresistive sensor and welded metallic membrane is used in all industries for continuous measurement in liquids, vapors and gases. The 3-key operation enables simple and reliable commissioning and operation. The integrated HistoRO

カタログの1ページ目を開く
PMD75 - 2

management of process and device parameters. Designed according to IEC 61508 for use in SIL2/3 safety applications. Features and specifications Liquids Measuring principle Differential pressure Product headline Digital transmitter with metallic measuring diaphragms Modular transmitter Long-term stability High static pressure/Overload resistance Enhanced safety via self diagnostic functions Secondary process barrier Max. measurement error 0,075% "PLATINUM" 0,05% Max. process pressure max. 420 bar (max. 2175 psi) Medium temperature range Temperature gradient from pressure piping...

カタログの2ページ目を開く
PMD75 - 3

Digital communication HART PROFIBUS PA FOUNDATION Fieldbus Hazardous area approvals ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS Functional safety Measuring principle Differential pressure Product headline Digital transmitter with metallic measuring diaphragms Modular transmitter Long-term stability High static pressure/Overload resistance Enhanced safety via self diagnostic functions Secondary process barrier Max. measurement error 0,075% "PLATINUM" 0,05% Max. process pressure

カタログの3ページ目を開く
PMD75 - 4

Medium temperature range Temperature gradient from pressure piping Display/Operation Option Outputs 4...20mA HART PROFIBUS PA FOUNDATION Fieldbus Digital communication HART PROFIBUS PA FOUNDATION Fieldbus Hazardous area approvals ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS Functional safety Continuous / Liquids Measuring principle Differential pressure Characteristic / Application Digital transmitter with metallic measuring diaphragms Modular transmitter Long term stability High static pressure/Overload resistance Enhanced safety via self diagnostic functions Secondary process barrier

カタログの4ページ目を開く
PMD75 - 5

Continuous / Liquids Supply / Communication 4...20 mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC Accuracy Standard: 0.05% Platinum: up to 0.035% Long term stability 0,05% of URL/year Ambient temperature -40 °C...85 °C (-40 °F...185 °F) Process pressure absolute / max. overpressure limit 420 bar (6300 psi) Pressure measuring range 10 mbar...250 bar (0.15 psi...3750 psi) Main wetted parts Alloy C276 316L Monel Tantalum

カタログの5ページ目を開く
PMD75 - 6

Continuous / Liquids Process connection 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC Safety approvals EN 10204-3.1 NACE MR0175, MR0103 Marine approval HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing Successor Measuring cell: Metal welded

カタログの6ページ目を開く
PMD75 - 7

Measuring principle Differential pressure Product headline Digital transmitter with metallic measuring diaphragms Modular transmitter Long-term stability High static pressure/Overload resistance Enhanced safety via self diagnostic functions Secondary process barrier Max. measurement error 0,075% "PLATINUM" 0,05% Max. process pressure max. 420 bar (max. 6091 psi) Medium temperature range Temperature gradient from pressure piping Display/Operation Option Outputs 4...20mA HART PROFIBUS PA FOUNDATION Fieldbus Digital communication HART PROFIBUS PA FOUNDATION Fieldbus Hazardous area approvals...

カタログの7ページ目を開く
PMD75 - 8

Functional safety Measuring principle Differential pressure Characteristic Digital transmitter with metallic measuring diaphragms Modular transmitter Long-term stability High static pressure/Overload resistance Secondary process barrier Supply voltage 4...20 mA HART 10,5...45V DC (Non Ex): Ex ia: 10,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex) Reference Accuracy Standard: 0.05% Platinum: up to 0.035% Long term stability 0.03 % of URL/ year 0.05 % of URL/ 5 years 0.08 % of URL/ 10 years

カタログの8ページ目を開く
PMD75 - 9

Process temperature 10 mbar...250 bar (0.15 psi...3750 psi) Smallest calibratable span 1 mbar (0.015 psi) Vacuum resistance 50 mbar (0.73 psi) Max. Turn down On one side: 420 bar (6300psi) Process connection 1/4-18NPT RC1/4" Material process membrane 316L, AlloyC, Tantal, Gold-Rhodium Material gasket Viton, PTFE, EPDM, NBR

カタログの9ページ目を開く
PMD75 - 10

Fill fluid Silicone oil Inert oil Material housing 316L, Die-cast aluminum Communication 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC Safety approvals NACE MR0103 EN10204-3.1 Marine approvals Diagnostic functions Successor addresses.endress.com info@endress.com

カタログの10ページ目を開く

Endress+Hauser AG/エンドレスハウザーのすべてのカタログと技術パンフレット

  1. FTL41

    3 ページ

  2. FTL51B

    6 ページ

  3. FMG50

    10 ページ

  4. PTP31B

    3 ページ

  5. CUS71D

    3 ページ

  6. iTEMP TMT162

    3 ページ

  7. CLS54D

    3 ページ

  8. CLS50D

    3 ページ

  9. FMX21

    5 ページ

  10. Liquipoint FTW23

    3 ページ

  11. Deltapilot FMB50

    7 ページ

  12. iTHERM TM401

    3 ページ

  13. COS61D

    3 ページ

  14. Proline Promag 10W

    4 ページ

  15. Proline Promag 10P

    4 ページ

  16. Liquiphant FTL51

    6 ページ

  17. FMD72

    5 ページ

  18. PMP51

    7 ページ

  19. Cerabar PMC51

    7 ページ

  20. Cerabar PMP75

    8 ページ

  21. FMD78

    8 ページ

  22. FMI51

    4 ページ

  23. FMU30

    7 ページ

  24. FMP57

    4 ページ

  25. FMP55

    4 ページ

  26. FMP54

    5 ページ

  27. FMP51

    5 ページ

  28. FMP50

    4 ページ

  29. FMR52

    4 ページ

  30. FMR51

    5 ページ

  31. F 200

    13 ページ

  32. D 200

    12 ページ

  33. E 100

    5 ページ

  34. C 200

    11 ページ

  35. B_unit4_1

    1 ページ

  36. B_unit3_3

    1 ページ

  37. B_unit3_2

    1 ページ

  38. Wort cooler

    1 ページ

  39. Liquiphant T FTL20

    20 ページ

  40. Gammapilot M FMG60

    48 ページ

  41. Deltabar S PMD70

    96 ページ

  42. Deltapilot S FMB70

    56 ページ

  43. Liquicap T FMI21

    40 ページ

  44. Prosonic S FDU91

    40 ページ

  45. Levelflex M FMP40

    72 ページ

  46. Micropilot FMR50

    76 ページ

カタログアーカイブ

  1. System components

    20 ページ

  2. Flow Measurement

    32 ページ