カタログの抜粋

Wastewater Industry Solutions Complete and Reliable Liquid Analysis Visualize > Analyze > Optimize ROSEMOUNT EMERSON Ana lytica I Process Management
カタログの1ページ目を開く
TRUSTED AROUND THE WORLD: THE MOST ADVANCED LIQUID ANALYSIS SOLUTIONS WE START WITH ONE IDEA IN MIND: MAKE IT CLEAN Homes, industry, schools and businesses all generate sani- of experience to work for you by delivering the best in tary wastewater, or sewage. Wastewater is +99% water knowledge and systems, and by doing it quickly, thoroughly and about 0.3% dissolved and suspended solid material. and cost-effectively, utilizing world-class Rosemount Visualize an online analytical solution for wastewater Analytical sensors and instrumentation. treatment that reduces labor with rugged...
カタログの2ページ目を開く
FOR MORE INFORMATION ON INDUSTRIES AND APPLICATIONS, SEE US ON THE WEB AT WWW.RAIHOME.COM Wastewater Treatment Solutions pH Measurement • Effluent pH monitoring Wastewater is generated by homes, businesses, and industries and is treated in two major steps, primary and secondary treatment, with disposal of solids during both steps. Analytical measurements such as pH, ORP, and suspended solids are performed during the primary treatment stage in order to monitor the removal of solids from the wastewater. Chlorine Measurement • Monitoring chlorine in final treatment Dissolved Oxygen Measurement...
カタログの3ページ目を開く
PRIMARY TREATMENT Influent Treatment Mechanical or Physical Separation of Solids The main activity of treatment occurring in the Primary Treatment stage consists of mechanical or physical separation of the solids from the liquid. At the plant inlet, wastewater can be loaded with biological activity producing nuisance odors and hazardous In many wastewater plants, the influent pH and conductivity are measured. These measurements are used for monitoring purposes, and will alert the plant operator of a possible upset condition. A sudden change in influent conductivity, for example, may...
カタログの4ページ目を開く
A combined sewer system design carries both sanitary wastewater and storm water in the same pipe to the treatment plant. During periods of heavy rainfall or snow melt, the wastewater volume may exceed the plant capacity and excess untreated wastewater is discharged to nearby streams, rivers, and lakes. This discharge disturbs the biological systems, may contaminate our drinking water sources, and creates threats to public health by coming in contact with untreated wastewater. The United States EPA estimates there are thousands of these incidents each year. Regulation, guidelines and...
カタログの5ページ目を開く
SECONDARY TREATMENT the floc use up the DO first. If this happens, the floc breaks up. Remove Remaining Organics Secondary treatment removes up to 85% of the remaining organic material through a biological process by cultivating and adding sewage microorganisms to the wastewater. This process is accomplished in a trickling filter or an aeration tank. A trickling filter uses With a complete range of measurement inputs that can be configured in any combination, the Model 1056 is ideal for municipal plants with dual measurement requirements. a bed of stones or pieces of corrugated plastic...
カタログの6ページ目を開く
maintain the correct amount of DO in the secondary treatment stage. And according to the USEPA, plant energy costs may be reduced by as much as 50 percent. DO introduced in the aeration basins also provides the added benefit of mixing, thus bringing the microorganisms, oxygen, and nutrient together. Mixing also removes metabolic waste products. Too much mixing can break up the floc or form unstable floc particles. If there is inadequate mixing, proper secondary treatment will not take place since there is a lack of contact between the bugs, their food and the oxygen source. Finally, the...
カタログの7ページ目を開く
SLUDGE TREATMENT ADDITIONAL TREATMENT Volume Reduction and Decomposition Volume Reduction and Decomposition During the wastewater treatment process, sludge has been generated along the way from the settling basins or clarifiers, and secondary treatment. This sludge contains high concentrations of microorganisms, many of which are pathogenic, and will decay and produce odors. Sludge however can be used for a soil conditioner, agricultural fertilizer, or for landfill after it has been treated to remove the harmful contaminants. Since the early 1970's, an optional stage that falls between...
カタログの8ページ目を開く
FINAL TREATMENT Disinfection In the final stage of wastewater treatment, disinfectants are added to kill disease-causing organisms and microorganisms used in the treatment process. Disinfection inactivates or destroys pathogenic organisms and prevents the spread of waterborne diseases to down-stream users and the environment. A common disinfectant is chlorine gas, but some municipalities use their own chlorine solution such as sodium hypochlorite. ORP Sensor Model 396P can be used to establish the ORP starting point. In many areas, local or national agencies regulate the amount of chlorine...
カタログの9ページ目を開く
10 No NA Yes NA No FOUNDATION fieldbus Compatible Wireless THUM Adaptor compatible Multi-lingual Menus Relays PID Control Timer control only 4 Yes Yes No Yes Class 1, Div. 1 FM, CSA, CE, UL CE, CSA Yes HART Compatible Yes Available Approvals Yes SMART pH pH/ORP/ISE, Conductivity, Resistivity, % Concentration, Dissolved Oxygen, Ozone, Flow, Turbidity, Chlorine * * (Total, Free, Monochloramine, pH Independent Free Chlorine) Class I, Div 2 pH and contacting conductivity Available Measurements Two (future option) One Number of Sensor Inputs Two Area Classifications Wireless Number of 4-20 mA...
カタログの10ページ目を開く
EMERSON PROCESS MANAGEMENT: THE PROVEN SOURCE Emerson Process Management is the proven supplier of Rosemount Analytical on-line electrochemical sensors and instrumentation with over 60 years experience in drinking water treatment, waste treatment and process control. In recognition of our dedication to customer service, product excellence, and quality we have received the #1 Readers Choice Award from Control Magazine for the sixteenth consecutive year. With a fixed amount of fresh water available for consumption and our worldwide increased demand for access to safe water, continuous...
カタログの11ページ目を開くEmerson Automation Solutions - ROSEMOUNTのすべてのカタログと技術パンフレット
-
FRL Accessories
14 ページ
-
TankRadar Pro
32 ページ
-
Roxar subsea PIG
2 ページ
-
Roxar subsea CM10K
2 ページ
-
Roxar PTPT15K
2 ページ
-
SW-300
4 ページ
-
DL8000
12 ページ
-
DeltaV Analyze
8 ページ
-
AMS Machine Works
4 ページ
-
Rosemount 975UR
4 ページ
-
Rosemount 975HR
4 ページ
-
Rosemount 975UF
4 ページ
-
Rosemount 975MR
4 ページ
-
Safety Monitoring
6 ページ
-
AMS Suite
16 ページ
-
Line Card
2 ページ
-
Drinking Water Industry
16 ページ
カタログアーカイブ
-
UVS Flame Detector
4 ページ