カタログの抜粋

Product Data Sheet CT5200 Industrial Gas Analyzer Cascade’s Industrial gas analyzers implement a hybrid multicomponent system (QCL and TDL), the system’s interchangeable modular configuration will allow for up to nine lasers to detect up to 20 gases in a variety of industrial and harsh environments. The Industrial Gas Analyzers embedded ARM processor enables the system to fully operate autonomously and it's automated verification and health diagnostics reporting ensures smooth-running in hazardous and critical applications that necessitate high operational reliability. CT5200 Industrial Gas Analyzer The worlds first hybrid Multicomponent QCL, TDL analyzer JJ "True multicomponent" analyzer – up to 20 gases JJ All solid state, no moving parts JJ Low maintenance and low lifetime cost JJ Embedded ARM processor for fully autonomous operation JJ No calibration required JJ Continuous health diagnostic reporting JJ Intuitive simple front panel user interface allows access to all instrument functions JJ “At sensor” data download capability for offline analysis Field serviceable and field configurable JJ Interchangeable modular configuration for up to 9 lasers Hazardous certification available JJ Europe, ATEX II 2 G, groups IIC JJ North America, Class I Division 2, groups A, B, C, D Designed and rated for outdoor use JJ No need to use valuable shelter real estate Mounting options JJ Available in wall mount and rack mount configurations Applications JJ Petrochemical process monitoring JJ Ethylene/propylene product impurities JJ Natural/shale gas JJ Process analytics in hazardous environments JJ Continuous Emissions Monitoring (CEMs) JJ Other applications available on request
カタログの1ページ目を開く
Specifications Table 1 - CT5200 Industrial Gas Analyzer Specifications Value Application Measurement technique Laser classification CLASS 1 BS EN 60825-1:2007 Safety of laser products Equipment classification and requirements (identical to IEC 60825-1 2007) Performance Repeatability Measurement rate Environmental Temperature range Sample gas temperature range Humidity range Protection class Hazardous area classification Inputs and Outputs Analogue signal out 6 x 4–20 mA measurement output (option) 4 x 4–20 mA signal input (option) 3 x normally closed contact fault relay outputs Modbus TCP,...
カタログの2ページ目を開く
Table 2 - Measurement Performance Other gases and ranges are available on request. The ranges and detection limits provided indicate typical analyzer performance but may change depending on your application. Please contact Rosemount Analytical for more information.
カタログの3ページ目を開く
Product Data Sheet Recommended Installation The drawings below represent the minimum recommended installation guidelines for the CT5200 Industrial Gas Analyzer. Please consult Rosemount Analytical for detailed installation recommendation of your application. Figure 1 - CT5200 Industrial Gas Analyzer www.RosemountAnalytical.com www.analyticexpert.com ©2015 Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their respective owners. HEADQUARTERS Emerson Process Management Glendevon House...
カタログの4ページ目を開くEmerson Automation Solutions - ROSEMOUNTのすべてのカタログと技術パンフレット
-
FRL Accessories
14 ページ
-
TankRadar Pro
32 ページ
-
Roxar subsea PIG
2 ページ
-
Roxar subsea CM10K
2 ページ
-
Roxar PTPT15K
2 ページ
-
SW-300
4 ページ
-
DL8000
12 ページ
-
DeltaV Analyze
8 ページ
-
AMS Machine Works
4 ページ
-
Rosemount 975UR
4 ページ
-
Rosemount 975HR
4 ページ
-
Rosemount 975UF
4 ページ
-
Rosemount 975MR
4 ページ
-
Safety Monitoring
6 ページ
-
AMS Suite
16 ページ
-
Line Card
2 ページ
-
Drinking Water Industry
16 ページ
カタログアーカイブ
-
UVS Flame Detector
4 ページ