CT2211 Leak Detection System Product Data Sheet Leak Detection System The European Commission’s Aerosol Dispensers Directive (ADD) legislation (UN ADR 2013, 75/324/EEC) mandates that aerosol dispensers and small receptacles containing compressed gas (gas cartridges) must pass a leak-proof test before they are transported. Aerosol manufacturers have traditionally relied on water bath testing to verify the integrity of aerosol products. This technique, however, is costly, resource intensive and highly disruptive to production.[1] Cascade’s CT2211 leak detection system detects and rejects leaking aerosol cans up to a rate of 500 cans per minute. The system is contactless, ensuring minimal product damage or contamination. Its design allows for the detection of a wide range of propellants including LPG, R134a, CO2, N2O, and DME while continuous health monitoring features result in lower maintenance costs and higher operational reliability. With the increasing number of safety and quality standards required, Cascade’s CT2211 will ensure current and future regulatory compliance. Water bath testing alternatives, such as QCL, speed the production process by eliminating the water bath bottleneck and in turn offer reduced floor space utilization and energy consumption leading to higher customer ROI. CT2211 Leak Detection System Instantaneous response JJ High velocity sample delivery JJ 20 millisecond analysis time JJ 500 cans per minute JJ Automated rejection/alarm JJ Continuous health monitoring High sensitivity JJ 2 x 10-3 mbar.L.sec -1 JJ Independently accredited, suitable for waterbath alternative Field serviceable and field configurable JJ Modular design for easy customization JJ Field replaceable parts JJ Low maintenance/zero consumables JJ Automated cell and filter purge Typical applications ATEX certified Other applications available on request JJ Configurable archway samples air from all around the can JJ Leaks detected from all vulnerable points
カタログの1ページ目を開く
CT2211 Leak Detection System Specifications Table 1 - CT2211 Leak Detection System Specifications Value Application Leak Detection System Measurement technique Quantum Cascade Laser Laser classification CLASS 1 BS EN 60825-1:2007 Safety of laser products Equipment classification and requirements (identical to IEC 60825-1 2007) Performance Sensitivity Line speed Response time Environmental Temperature range Sample gas temperature range Room temperature Humidity range Protection class Hazardous area classification Inputs and Outputs 3 x normally closed contact Inlet gas port connector Exhaust...
カタログの2ページ目を開く
CT2211 Leak Detection System Table 2 - Configuration Configuration Pedestal Control and Rejection System (out of zone) Out of Zone Status Lamps (Red, Amber and Green) Interface to Customer PLC (240 signals) Production Line Reject Chute Standard Equipment ATEX Zone 2 Leak Detector Wall Mount Control and Rejection System (out of zone) Line Encoder Air Pressure Monitoring Performance Options Project Options Air Mechanical Soft KEY: • Standard, o Option, - n/a Other gases and ranges are available on request. The ranges and detection limits provided indicate typical analyzer performance but may...
カタログの3ページ目を開く
CT2211 Leak Detection System Product Data Sheet Recommended Installation The drawings below represent the minimum recommended installation guidelines for the CT2211 Leak Detection System. Please consult Rosemount Analytical for detailed installation recommendation of your application. Figure 1 - CT2211 Leak Detection System Emerson Process Management Glendevon House Castle Business Park, FK9 4TZ ©2015 Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount Analytical is a mark of Emerson Process Management family of...
カタログの4ページ目を開くEmerson Automation Solutions - ROSEMOUNTのすべてのカタログと技術パンフレット
-
FRL Accessories
14 ページ
-
TankRadar Pro
32 ページ
-
Roxar subsea PIG
2 ページ
-
Roxar subsea CM10K
2 ページ
-
Roxar PTPT15K
2 ページ
-
SW-300
4 ページ
-
DL8000
12 ページ
-
DeltaV Analyze
8 ページ
-
AMS Machine Works
4 ページ
-
Rosemount 975UR
4 ページ
-
Rosemount 975HR
4 ページ
-
Rosemount 975UF
4 ページ
-
Rosemount 975MR
4 ページ
-
Safety Monitoring
6 ページ
-
AMS Suite
16 ページ
-
Line Card
2 ページ
-
Drinking Water Industry
16 ページ
カタログアーカイブ
-
UVS Flame Detector
4 ページ