

カタログの抜粋

Edwards TIC product range is a series of vacuum instrument controllers providing compact control with a large, clear graphical display, an intuitive user interface and serial communications. program provides full remote setup, control and data logging functions via The range includes three-head, six-head, and six-head capacitance manometer compatible versions, which support and automatically recognize up to six Edwards Active vacuum gauges, including the Active Ion Gauge Controller (EB version) and Barocel™ capacitance manometers, to provide coverage from 2000 to Capacitance Manometer Protection Six User Configurable Relay Set-points Display of Relay Status One 0-10 V Buffered Analog Output for each gauge channel Web-based Product Support page Direct Pressure Readout of common conversion factors User-Configurable Display Options include: - Option to display one, three, or six channels - Ability to select gauge order when cycling - The display Assign a four character alpha- numeric name for each gauge (e.g RV1, LL2,
カタログの1ページ目を開く
Technical Data ELECTRICAL DATA Connector type Electrical supply Power consumption Earth stud OPERATING AND STORAGE DATA Ambient operating temperature range Ambient storage temperature range Maximum ambient operating humidity Maximum operating altitude I EC rated pollution degree MECHANICAL DATA The unit is self-protecting and has no user replaceable fuse. The unit will recover once any overload is removed. The figure illustrates the use of Active Pirani Gauge (APG100) and Active Inverted Magnetron Gauges (AIM), which may be replaced by asingleWide Range Gauge (WRG). The logic interface (M)...
カタログの2ページ目を開く
External Interfaces And Configuration Options Logic interface Control inputs Status outputs Serial interface The logic interface connector may be used either to link to system relays, a higher-level control system, or an optional relay box. By utilizing the relay box pass-through connector, a combination of a higher-level control system and relay box may be used. Gauge enable: System interlock: Analog output: Open when high: 4 to 24 V DC SYSI closed when low: < 0.5 V DC Open when high: 4 to 24 V DC 1 for each gauge channel 0-10 V DC The TIC has two built-in communications protocols, RS232...
カタログの3ページ目を開く
Access the Configuration Manager in order to: • Link gauge channels for pressure control of high vacuum gauges • Create, save, and load custom configurations • Lock the TIC software configuration or front panel Each TIC is supplied with a fully functional Windows™ based PC software interface, which replicates and adds to the TIC embedded control menus. The PC Monitor software enables TIC systems to be configured, controlled and monitored from a single PC: • Control gauge functions such as degas and calibrate • Energize or de-energize gauges • Access other PC Monitor control functions A...
カタログの4ページ目を開く
Compatible Gauges * The AIGX draws 8W in normal operation, 15W in degas mode. The total power available to drive the gauges is limited to 38 W. Additionally, for capacitance manometers, power Two relay boxes are available to allow the TIC set point outputs to operate either three 250V AC, 3A or six 250V AC, 5A (non-inductive) changeover relays. The relay box is equipped with a logic connector to allow interfacing with the TIC, and with a separate bypass connector for interfacing with other external control equipment. 1 250V ac 3A changeover relays (3 channel) 2 Logic interface (from TIC)
カタログの5ページ目を開く
Ordering Information TIC Instrument Controller 3 head RS232/RS485 TIC Instrument Controller 6 head RS232/RS485 TIC Instrument Controller 6 head RS232/RS485 Capman Calibrated Instrument Controllers Controllers are supplied with a certificate of calibration traceable to national standards. TIC Instrument Controller 3 head RS232/RJ485 + calibration certificate TIC Instrument Controller 6 head RS232/RJ485 +calibration certificate TIC Instrument Controller 6 head Capman + calibration certificate The above controllers are calibrated on their own without gauges. Contact Edwards for controllers...
カタログの6ページ目を開くEDWARDS/エドワーズのすべてのカタログと技術パンフレット
-
SPEEDIVALVE
2 ページ
-
GV
12 ページ
-
XDD1
2 ページ
-
PGC
2 ページ
-
8200
2 ページ
-
IS 320FX
2 ページ
-
RGA
8 ページ
-
EH
2 ページ
-
RV
8 ページ
-
nXDS
12 ページ
-
XDS series
4 ページ
-
nXLi DRY PUMPS
2 ページ
-
XDS DRY SCROLL PUMPS
4 ページ
-
nXDS DRY SCROLL PUMPS
12 ページ
-
T-STATION 85
2 ページ
-
AIM
2 ページ
-
WRG
2 ページ
-
ASG2
2 ページ
-
ELD500
8 ページ
-
nEXT Turbo Pumps
12 ページ
-
EXT Turbo Pumps
4 ページ
-
IPUP2 Dry Pump
2 ページ
-
iXL1000 Dry Pump
2 ページ
-
iXH Dry Pumps HF
2 ページ
-
iXH Dry Pumps
2 ページ
-
iH Dry Pumps Product
12 ページ
-
RV Pumps
8 ページ
-
ES Rotary Vane Pumps
16 ページ
-
Small EM Pumps
12 ページ
-
MAXX Dry Systems
16 ページ
-
GXS Dry Pumps
20 ページ
-
nXDS Accessories
32 ページ
-
TiTan Ion Pumps
4 ページ
-
EDP Pumps
4 ページ
-
CXS Dry Pumps
12 ページ
-
Edwards_Product_Catalogue
604 ページ
-
ADC Datasheet
4 ページ
-
Acoustic enclosures
2 ページ
-
nEXT Brochure
12 ページ
-
nXDS Scroll Pumps
12 ページ
-
PRODUCT CATALOGUE 2012
470 ページ
-
CXS Dry Pump
9 ページ
-
EV Brochure
6 ページ
-
Spectra G
4 ページ
-
iGX Dry Pumps
4 ページ
-
iXL120 Dry Pump
2 ページ
-
T-Station 75
2 ページ
-
EXT75-255DX
6 ページ
-
XDS Dry Scroll Pump
6 ページ
-
APGX-H Datasheet
4 ページ
-
APG100 Datasheet
2 ページ
-
Vapour Booster Pumps
60 ページ
-
RV Rotary Vane Pumps
6 ページ
-
XDS Scroll Pumps
2 ページ
カタログアーカイブ
-
RV Brochure
6 ページ
-
Dry pump brochure
12 ページ
-
Liquid Ring Pumps
2 ページ
-
Mechanical Booster
12 ページ