This manual provides installation, operation and maintenance instructions for the Edwards RV3, RV5, RV8 and RV12 Rotary Vane Pumps. You must use your pump as specified in this manual.Read this manual before you install and operate your pump. Important safety information is highlighted as WARNING and CAUTION instructions; you must obey these instructions. The use of WARNINGS and CAUTIONS is defined below. > Warnings are given where failure to observe the instruction could result in injury or death to people. > Cautions are given where failure to observe the instruction could result in damage...
カタログの7ページ目を開く
A65201֖880 IssueS Page 2 Edwards Limited 2007. All rights reserved.Edwards and the Edwards logo are trade marks of Edwards Limited. > Introduction This equipment is designed to meet the requirements of GroupII Category3 equipment in accordance with Directive94/9/EC of the European Parliament and the Council of 23rdMarch1994 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres. (The ATEX Directive).The ATEX Category3 applies in respect of potential ignition sources internal to the equipment. An...
カタログの8ページ目を開く
A65201֖880 IssueS > Introduction Figure 1 - The RV pump 1.Electrical inlet-connector2.Voltage indicator3.Lifting handle * 4.NW25 inlet-port5.Gas-ballast control6.Oil filler-plug 7.NW25 outlet-port8.Oil-level sight-glass9.Oil drain-plug10.Rubber feet (4off) 11.Mode selector12.On-off switch > 13.Motor fan-cover14.Correct direction of rotation*RV3 and RV5 pumps only; a lifting bracket is fitted to RV8 and RV12 pumps.ƆSingle-phase pumps only. Note: Single-phase RV3/RV5 pump shown. Edwards Limited 2007. All rights reserved. Page 3Edwards and the Edwards logo are trade marks of Edwards Limited. >
カタログの9ページ目を開く
A65201֖880 IssueS Page 4 Edwards Limited 2007. All rights reserved.Edwards and the Edwards logo are trade marks of Edwards Limited. > Introduction The Edwards RV rotary vane pump is shown in Figure1. Refer to Figure1 for item numbers in brackets in the following descriptions. The RV pumps are two-stage, oil-sealed, sliding-vane vacuum pumps. The pump has NW25 inlet (4) and outlet (7) ports, a gas-ballast control (5) and a mode selector (11). When the pump is switched off, an inlet-valve seals the inlet and prevents the suck-back of air and oil into the vacuum system.The RV3 and RV5 pumps...
カタログの10ページ目を開く
To pump high vapour loads, gas-ballast is delivered into the pump to prevent condensation of the vapour carried by the pumped gases.Air can be introduced to the low vacuum stage through the gas-ballast valve. Alternatively, an inert gas such as nitrogen can be supplied through a suitable external valve.The gas-ballast control has three positions: Closed (position0ђ) Low flow (positionIђ) High flow (positionIIђ). > The pump-shafts and rotors are made of high-grade cast-iron. The pump-body and oil-box are made from cast-aluminium. All surfaces of the pump which are exposed to the pumped gases...
カタログの11ページ目を開く
A65201֖880 IssueS Page 6 Edwards Limited 2007. All rights reserved.Edwards and the Edwards logo are trade marks of Edwards Limited. This page has been intentionally left blank. >
カタログの12ページ目を開く
A65201֖880 IssueS > Technical data Note: The performance characteristics described below are for use with hydrocarbon oil. The positions of the mode selector and the gas-ballast control define the performance characteristics of the pump. These performance characteristics are listed fully in Tables3 and4.Table5 gives the ultimate vacuum and maximum water vapour inlet pressure for each of the six possible combinations of control positions. The curves0, I, andII in Figure2 show the relationship between inlet pressure and pumping speed for High Vacuum mode Figure 2 - Performance characteristics...
カタログの17ページ目を開く
A65201֖880 IssueS Page 16 Edwards Limited 2007. All rights reserved.Edwards and the Edwards logo are trade marks of Edwards Limited. This page has been intentionally left blank. >
カタログの22ページ目を開く
We recommend that you do not use a hydrocarbon-prepared RV pump for pumping hazardous substances. PFPE-prepared pumps are suitable for oxygen applications: refer to Section8. You must ensure that the RV pump is suitable for your application. If you have any doubt as to the suitability of the RV pump for your application, refer to the Edwards guidelines on vacuum pump and vacuum system safety (see the Associated publications at the end of the Contents list at the front of this manual).A suitably trained and supervised technician must install your RV pump. Obey the safety instructions listed...
カタログの23ページ目を開く
A65201֖880 IssueS Page 18 Edwards Limited 2007. All rights reserved.Edwards and the Edwards logo are trade marks of Edwards Limited. > Installation 1.Remove all packing materials, and remove the pump from its packing-box.2.Remove the protective covers from the inlet and outlet-ports and inspect the pump. If the pump is damaged, notify your supplier and the carrier in writing within three days; state the Item Number of the pump together with your order number and your supplierɒs invoice number. Retain all the packing materials for inspection. Do not use the pump if it is damaged.If the pump...
カタログの24ページ目を開く
If you have a bareshaft pump, fit the motor to the pump now: refer to Section9. > Ensure that the motor is correctly configured for your electrical supply. If you operate the pump when the motor is not correctly configured for the electrical supply, you will damage the motor. Refer to Figure4 for the item numbers in brackets.Ensure that the voltage shown on the voltage indicator (4) in the motor-cover corresponds with your electrical supply voltage. If it does not, you must change the configuration of the pump-motor to match your electrical supply voltage; use the procedure below.1.Undo the...
カタログの25ページ目を開くEDWARDS/エドワーズのすべてのカタログと技術パンフレット
-
SPEEDIVALVE
2 ページ
-
GV
12 ページ
-
XDD1
2 ページ
-
PGC
2 ページ
-
8200
2 ページ
-
IS 320FX
2 ページ
-
RGA
8 ページ
-
EH
2 ページ
-
RV
8 ページ
-
nXDS
12 ページ
-
XDS series
4 ページ
-
nXLi DRY PUMPS
2 ページ
-
XDS DRY SCROLL PUMPS
4 ページ
-
nXDS DRY SCROLL PUMPS
12 ページ
-
T-STATION 85
2 ページ
-
AIM
2 ページ
-
WRG
2 ページ
-
ASG2
2 ページ
-
ELD500
8 ページ
-
nEXT Turbo Pumps
12 ページ
-
EXT Turbo Pumps
4 ページ
-
IPUP2 Dry Pump
2 ページ
-
iXL1000 Dry Pump
2 ページ
-
iXH Dry Pumps HF
2 ページ
-
iXH Dry Pumps
2 ページ
-
iH Dry Pumps Product
12 ページ
-
RV Pumps
8 ページ
-
ES Rotary Vane Pumps
16 ページ
-
Small EM Pumps
12 ページ
-
MAXX Dry Systems
16 ページ
-
GXS Dry Pumps
20 ページ
-
nXDS Accessories
32 ページ
-
TiTan Ion Pumps
4 ページ
-
EDP Pumps
4 ページ
-
CXS Dry Pumps
12 ページ
-
Edwards_Product_Catalogue
604 ページ
-
ADC Datasheet
4 ページ
-
Acoustic enclosures
2 ページ
-
nEXT Brochure
12 ページ
-
nXDS Scroll Pumps
12 ページ
-
PRODUCT CATALOGUE 2012
470 ページ
-
CXS Dry Pump
9 ページ
-
EV Brochure
6 ページ
-
Spectra G
4 ページ
-
iGX Dry Pumps
4 ページ
-
iXL120 Dry Pump
2 ページ
-
T-Station 75
2 ページ
-
EXT75-255DX
6 ページ
-
XDS Dry Scroll Pump
6 ページ
-
APGX-H Datasheet
4 ページ
-
APG100 Datasheet
2 ページ
-
Vapour Booster Pumps
60 ページ
-
RV Rotary Vane Pumps
6 ページ
-
XDS Scroll Pumps
2 ページ
カタログアーカイブ
-
RV Brochure
6 ページ
-
Dry pump brochure
12 ページ
-
Liquid Ring Pumps
2 ページ
-
Mechanical Booster
12 ページ