Plug-in Circuit-Breakers/Switch-Disconnectors Safe and easy electrical separation of the system for service purposes or while replacing the circuit-breaker. An auxiliary-conductor connector allowing to plug in either an operating current/undervoltage trip, a remote control or an auxiliary contact is available as an option. It enables the user to do the functions test without closing/ opening any active main conductor lines. The range of accessories including the connecting technology for the fixed switchgear system can be used for it without any restrictions. Easy and safe to replace  Safe...

カタログの2ページ目を開く
Maximum system availability thanks to plug-in circuit-breakers NZM3-SVE - 4

Rated current = Rated uninterrupted current In = Iu A Setting range Overload release Ir A Setting range Short-circuit release Non-delayed Ii = In x... I I > I System and Cable Protection Comfort switching capacity Normal switching capacity 3-pole High switching capacity

カタログの4ページ目を開く
Maximum system availability thanks to plug-in circuit-breakers NZM3-SVE - 5

Rated current = Rated uninterrupted current In = Iu A Setting range Overload release Ir A Setting range Short-circuit release Non-delayed I, = In X... I I > I System protection, Cable Protection, selectivity, generator protection Normal switching capacity Motor protection • With phase-failure sensitivity Normal switching capacity 50 220 110-220

カタログの5ページ目を開く
Maximum system availability thanks to plug-in circuit-breakers NZM3-SVE - 6

Rated current = Rated uninterrupted current In = Iu A Setting range Overload release Ir A Setting range Short-circuit release Non-delayed Ii = In x... I I > I Short-Circuit protection Motor protection in conjunction with overload relay • With short-circuit releases • Without overload releases Comfort switching capacity 3-pole 36 Normal switching capacity 3-pole 50 250 N/A High switching capacity 3-pole 150 250 N/A

カタログの6ページ目を開く
Maximum system availability thanks to plug-in circuit-breakers NZM3-SVE - 7

Switch-disconnectors and Accessories 3- and 4-pole N Rated current = Rated uninterrupted current In = Iu A Short-circuit protection, max. fuse gL-characteristic Plug-in units For circuit-breakers NZM and switch-disconnectors N Ue max 690V For auxiliary contact shunt/undervoltage release Control circuit plug unit

カタログの7ページ目を開く
Maximum system availability thanks to plug-in circuit-breakers NZM3-SVE - 8

Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it's needed most. With unparalleled knowledge of electrical power management across industries, experts at Eaton deliver customized, integrated solutions to solve our customers' most critical challenges. Our focus is on delivering the right solution for the application. But, decision makers demand more than just innovative products. They turn to Eaton for an unwavering commitment to personal support that makes customer success a top priority. For more information, visit www.eaton.eu/electrical To...

カタログの8ページ目を開く

Eaton/イートンのすべてのカタログと技術パンフレット

  1. Green Switching

    4 ページ

  2. xEnergy Basic

    176 ページ

  3. xEnergy Light

    140 ページ

  4. Data Networks

    94 ページ

  5. SmartWire-DT Catalog

    108 ページ

  6. Product Launch

    3 ページ

  7. Cable glands

    34 ページ

  8. Crouse hinds

    272 ページ

  9. Protective Devices

    358 ページ

  10. Cam Switches T

    256 ページ

カタログアーカイブ

  1. New Items Catalogue

    38 ページ